Installation instructions

IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR ENTIRETY BEFORE INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional information is desired, please contact Signify, Lumec. TSC@signify.com phone 1-833-744-6439.

WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

  • Disconnect or turn off power before attempting any installation, service or maintenance.
  • Verify that supply voltage is correct by referencing the luminaire label information.
  • Make all electrical and ground connections by the National Electrical Code (NEC) and any other applicable laws, regulations, or codes.
  • All wiring connections should be capped with UL-approved wire connectors.

WARNING
RISK OF FIRE OR PERSONAL INJURY

  • Keep combustible materials away from LED/lamp & lens
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

  • Allow LED/lamp & lens to cool before handling.
  • Do not touch the enclosure or light source
  • Do not exceed the maximum wattage marked on the luminaire label.
  • Follow all manufacturer’s warnings, recommendations, instructions, and restrictions for driver type, burning position, mounting locations, and replacement.

CAUTION
RISK OF PRODUCT DAMAGE

  • Never connect luminaires and/or components under load with supply voltage turned on.
  • Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
  • Do not restrict fixture ventilation. Allow for some volume of airspace around the luminaire. Avoid covering the luminaire with insulation, foam or other material that will prevent convection or conduction cooling.
  • Do not exceed luminaire maximum ambient temperature.
  • Do not modify the luminaire.
  • Only use luminaire in its intended application and location.
  • Led products are polarity-sensitive. Ensure proper polarity before installation.
  • Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
  • Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
  • Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact Signify.
  • Always read the luminaire’s complete installation instructions before installation for any additional luminaire-specific warnings.
  • Do not install damaged products. Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts upon arrival of the luminaire.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance.
  • Please see luminaire-specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow any of these Instructions could void luminaire warranties.

Luminaire Maintenance

  • Regular luminaire maintenance programs are recommended.
  • It is recommended to clean the outside of the luminaire and the refractor/lens.
  • The frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user.
  • If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching, and non-abrasive cleaning substance.
  • Never use alkaline and/or acetous cleaning substances.
  • Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
  • Signify recommends using a cleaning solution that has a PH between 5 and 8.
  • Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.

READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS FIXTURE.

WARNING: THE ELECTRICAL POWER MUST BE DISCONNECTED DURING ALL INSTALLATION OR SERVICE WORK. FAILURE TO FOLLOW THE INSTALLATION DOCUMENTATION OR OPERATING THIS PRODUCT OTHERWISE THAN FOR ITS INTENDED USE VOIDS THE WARRANTY AND COULD RESULT IN SERIOUS INJURY, DEATH OR PROPERTY DAMAGE

  1. Unlock the fixture arm cover by loosening the thumb screw; to access the supporting bolts.
  2. Install optional bird guard for ø1.9” or ø1.66” OD tenons before sliding the fixture onto the tenon. See the important note below.
  3. Disconnect the power and slide the fixture onto the pole. See table for approximate penetration. The horizontal angle can be adjusted in 2.5° steps.
  4. Evenly tighten all 3/8-16 bolts of the bracket at 100 lbs-in (8.33 lbs-ft).
    • WARNING: Do not over or under-tighten bolts. This could result in serious injury, death, or property damage.
  5. Make sure the power is disconnected before connecting the service leads to the terminal block. Secure the connection by tightening the set screws. Torque: 20-25 lbs.in
  6. Close the fixture arm cover and tighten manually the thumb screw until it is secured.
  7. If equipped with the receptacle, adjust the orientation of the socket by loosening the receptacle screw with a flat screwdriver. Once adjusted, tighten back the screws.
  8. Install the shorting cap, photo control or other compatible device on top of the receptacle.
    • NOTICE: The luminaire will not operate if either a shorting cap OR a photo control is not installed.signify-S-RSC-RoadScape-LED-Light-FIG-1

IMPORTANT: Install the bird guard for ø1.9″ or ø1.66“ OD tenons. For ø1.9″ tenon, unfold the bird guard as shown and break away the smaller diameter lid at the folding line. FAILURE TO DO SO VOIDS THE WARRANTYsignify-S-RSC-RoadScape-LED-Light-FIG-2 signify-S-RSC-RoadScape-LED-Light-FIG-3signify-S-RSC-RoadScape-LED-Light-FIG-4

FCC Part 15 Class A Products FCC Markings

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAN ICES-005 (A) / NMB-005 (A)