PARKSIDE PTIA 1 Digital Laser Infrared Thermometer Instruction Manual

June 4, 2024
PARKSIDE

PTIA 1 Digital Laser Infrared Thermometer
Instruction Manual

PTIA 1 Digital Laser Infrared Thermometer

PDF ONLINE
www.Lidlservice.com 

INFRARED THERMOMETER
Operation and safety notes

List of pictograms used

| Please read the instructions for use.
---|---
| The danger of explosion!
| Wear safety gloves!
| Attention!
| Protect yourself from laser radiation!
| Do not stare into the laser beam!
| Direct current / voltage
| Including battery
| CE mark indicates conformity with relevant EU directives applicable to this product.
| UKCA mark indicates conformity with relevant Great Britain regulations applicable
for this product. (The UKCA mark logo is valid in Great Britain only.)

Infrared Thermometer

Introduction

We congratulate you on the purchase of your new product. You have chosen a high-quality product. The instructions for use are part of the product. They contain important information concerning safety, use, and disposal. Before using the product, please familiarise yourself with all of the safety information and instructions for use. Only use the
product as scribed and for the specified applications. If you pass the product on to anyone else, please ensure that you also pass on all the documentation with it.
Intended use
The product surface temperatures range from -50 °C to +380 °C (-58 °F to +716 °F) as well as comparing temperatures with a previously recorded reference value. The surfaces of several objects may be measured successively and the temperature deviations compared visually, by color, and acoustically. Only use the built-in laser pointer with 8
dot circle for measuring temperature to locate a measuring area on the product under test.
The product is only intended for private use and may not be used for commercial or industrial purposes. Only use the product in dry environments, resp. indoors. Any use of the product for other or additional purposes is considered improper use.  Any claims of damages resulting from improper use are excluded. The user is solely responsible for any and all damages or injuries due to risks of improper use.
Functionality
The infrared sensor 2 acquires and measures the infrared radiation emitted by the surface it is aimed at. The product determines the temperature of the surface from this infrared radiation.
The product features a laser pointer with 8 dot circle 1, pointing at the middle of the measuring range, to visualise the area of the surface the infrared sensor is acquiring the
radiation from.
The measuring range is a  circular area around his laser pointer with 8 dot circle which increases as the distance to the measuring distance increases. For details, please refer to
Chapter  „Measuringtemperature“.
Description of parts (Fig. A, B, C)

  1. Laser pointer with 8 dot circle
  2. Infrared sensor
  3. Measure button
  4. Battery cover
  5. Display
  6. Reference value display
  7. Temperature unit
  8. Measurement
  9. Tolerance range selection
  10. button
  11. °C / °F / SET button
  12. button
  13. ON/OFF button
  14.  9 V block battery

Scope of delivery

1 Infrared thermometer
1 9 V block battery
1 Set of instructions for use
Technical data

Power supply: 9 V(1 x 9 V block battery type 6F22 or 6LR61)
Measuring range: -50 °C to +380 °C (-58 °F to +716 °F)
Measurement accuracy for T > 0 °C:  ± 1.5 °C or ±1.5% of the measurement
Measurement accuracy for T < 0 °C: ± 3 °C or ±3% of the measurement
Laser class: 2
Laser wavelength: 650 nm
Laser output power: <1 mW
Operating temperature: 0 °C to 40 °C
Humidity: ≤ 75 %
Dimensions: approx. 18 x 12 x 4.2 cm
Weight without battery: approx. 189 g

Safety instructions

Before using the product, please familiarise yourself with all of the safety information and instructions for use! When passing this product on to others, please also include all the documents!
Danger from laser radiation

  • This product features a Class 2 laser.
  • Never direct the laser beam at persons or animals.
  • Never look directly into the beam. Even a weak laser beam can cause eye damage.
  • Never point the laser beam at reflective surfaces or materials. Even a reflected laser beam can cause eye damage.
  • Any adjustment intensifying the laser beam is prohibited. Risk of injury!
  • We assume no liability for damages arising from manipulating the laser product and for failure to observe the safety notices.
  • This product may be used by children age 8 years and up, as well as by persons with reduced physical, sensory or mental capacities, or lacking experience and knowledge, so long as they are supervised or instructed in the safe use of the appliance and understand the associated risks. Do not allow children to play with the product. Cleaning and user maintenance should not be performed by children without supervision.
  • Do not use this product if you notice any damage.
  • Keep away from open flames!
  • Protect the product from moisture and from liquids entering the product.
  • Avoid direct sunlight.
  • Do not modify the product.

CAUTION! EXPLOSION HAZARD! Do not use the product in locations with a fire hazard or explosion hazard, for example near flammable liquids or gasses. Safety instructions for batteries /rechargeable batteries

  • DANGER TO LIFE! Keep batteries/rechargeable batteries out of reach of children. If accidentally swallowed seek immediate medical attention.
  • Swallowing may lead to burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion.
  • DANGER OF EXPLOSION!   Never recharge non-rechargeable batteries. Do not short-circuit batteries/rechargeable batteries and/or open them. Overheating, fire, or bursting can be the result.
  • Never throw batteries/rechargeable batteries into fire or water.
  • Do not exert mechanical loads on batteries/rechargeable batteries.

Risk of leakage of batteries/rechargeable batteries

  • Avoid extreme environmental conditions and temperatures, which could affect batteries/rechargeable batteries, e.g. radiators / direct sunlight.

  • If batteries/rechargeable batteries have leaked, avoid contact with the skin, eyes, and mucous membranes with the chemicals! Flush immediately the affected areas with fresh
    water and seek medical attention!

  • WEAR PROTECTIVE GLOVES! Leaked or damaged batteries/rechargeable batteries can cause burns in contact with the skin. Wear suitable protective gloves at all times if such an event occurs.

  • In the event of a leakage of batteries/rechargeable batteries, immediately remove them from the product to prevent damage.

  • Only use the same type of batteries/rechargeable batteries. Do not mix used and new batteries/rechargeable batteries.

  • Remove batteries/rechargeable batteries if the product will not be used for a longer period.

Risk of damage to the product

  • Only use the specified type of battery / rechargeable battery!
  • Insert batteries/rechargeable batteries according to polarity marks (+) and -) on the battery / rechargeable battery and the product.
  • Use a dry lint-free cloth or cotton swab to clean the contacts on the battery / rechargeable battery and in the battery compartment before inserting!
  • Remove exhausted batteries/rechargeable batteries from the product immediately.

Before use

Note: To operate the product, insert the included battery (9 V block). Proceed as described below:
Inserting/changing the battery

  • To insert/change the 9 V block battery 14, open the battery cover 4. To do
    so, slide the battery cover in the direction of the arrow and flip it open.

  • If applicable, remove the old 9 V block battery and insert a new one. If necessary, clean the contacts of the battery compartment and the 9V block battery. Only use a  9V block battery type 6F22 or 6LR61.

  • Ensure the correct polarity when inserting the 9V block battery. This is indicated on the battery cover (Fig. C).

  • Close the battery cover. Your infrared thermometer is now ready for use.

Start-up

  • Hold the handle of the product so the index finger can operate the Measure button 3 and the thumb buttons 10 to 12.

Switching on and off

  • Press measure button 3 or the ON/OFF button 13 to switch on the product. Display 5 will light up and a brief tone will sound.
  • Press and hold the ON/OFF button 13 to switch off the product. Two brief tones will sound.
  • When the product is no longer being used, the backlight of the display will switches off after approx. 15 seconds. After approx. 60 seconds the product will automatically switch off; this is indicated by two brief tones.

Selecting the temperature unit
After switching on, the last temperature unit used will initially be selected.

  • Briefly press the °C / °F / SET button 11 to change the temperature units 7 (°C or °F).

The official temperature unit in Europe is °C.
Measuring temperature
Allow about 30 minutes for the product to acclimate to the conditions of the environment.

  • Hold the Measure button 3 whilst aiming the laser pointer with 8 dot circle 1 t the surface, you wish to measure.
  • The temperature is measured whilst pressing the Measure button; display 5 will read „SCAN“.
  • After releasing the Measure button the last temperature measured will appear in the display and the laser pointer with 8 dot circle will be deactivated.
  • The temperature determined is the average temperature of the area measured. The area measured is circular. The diameter of the area measured „S“ is one-twelfth of the distance between the surface and the infrared sensor 2 „D“. Below you will find some values as a guide:
S (for surface diameter): 10 mm 20 mm 30 mm
D (for distance): 120 mm 240 mm 360 mm

Please note:

  • The surface of the target object must be significantly larger than the measuring
    diameter of the product. Otherwise, the measurement will not be reliable.

  • Always measure at the closest possible distance to the measuring surface.

  • Aim the product as vertically to the measuring surface as possible.

  • Do not measure in dusty, steaming, or smoky atmospheres.

  • Do not measure through transparent materials such as glass or plastic.

Show temperature deviation
The temperature deviation is the difference between a previously established reference value and a temperature measurement. Display 5 indicates the deviations as numeric values and is displayed in color. An acoustic signal also sounds.
Determine reference value

  • Press the measure button 3 and aim the laser pointer with 8 dot circle 1 at the area in which you wish to use the temperature as the reference. The temperature is indicated in display  5.
  • Whilst holding the Measure button, press the °C / °F / SET button 11 to use the temperature value as the reference value. This temperature is indicated in the display next to „REF“ as reference display 6.

Select tolerance range
You can set the temperature deviation from the reference value as to which the product will respond with a visual and acoustic signal.

  • To do so, whilst the reference value 6 appears in display 5, press the button 10 or the button 12. Using this button the symbol will move to the right ( ) or to the left ( ) above the tolerance range 9 selection in the display.

Use this method to select the tolerance range indicated below the display:

Normal 0.5 °C1°F 3 °C 5°F 5.5 °C 10°F

Note: Under “Normal“ mode, the tolerance range for the temperature deviation function is turned off. So, no display color change / acoustic signal will be observed for any amount of temperature deviation from the reference value under the “Normal“ mode.
Scan temperature deviation

  • Select a reference temperature as described above.
  • Press the Measure button 3 and aim the laser pointer with 8 dot circle 1 at the area you wish to measure. The temperature is indicated in display 5.
  • Hold the measure button whilst scanning, and slowly and steadily move the laser pointer with an 8-dot circle across the surface you wish to measure. The temperature deviations between the reference value and the measurement are indicated as follows:
Visual indication Acoustic indication Cause
Red display background Rapid tone series The upper-temperature threshold has

been exceeded
Green display background| No tone| Within the temperature range setting
Blue display background| Slow tone series| The value is below the lower threshold

Example of use
To e.g. test cold air entering the space between a window frame and brickwork, first scan the temperature along the entire frame, next to the closed window. Select the warmest area of the frame as the reference temperature, then e.g. a temperature variation of 3 °C / 5°F. Now steadily scan again, along all sides of the window, next to the frame. The
blue color display and a slow tone series indicate a possible influx of cold air with a difference of 3 °C / 5°F.
Battery state display
The battery symbol appears in display 5 as soon as the battery voltage is too low.

  • Insert a new battery as described in the chapter „Inserting/replacing the battery“ when this symbol appears.
  • A drained battery may leak. In addition, the measurement may not be accurate as specified in „Technical data“ if the battery voltage is low.

Troubleshooting

Note: The product contains sensitive electronic components. For this reason, it is possible that it can be disrupted by radio transmitting equipment in the immediate vicinity. If you notice that the product is malfunctioning, remove any sources of interference from the area around the product.
Note: Electrostatic discharge can cause malfunctions. In the event of such malfunctions,  briefly remove and replace the battery.
The following table will help you locate and correct minor malfunctions:

Fault Possible cause Solution
Display 5 is blank. Battery 14 is inserted incorrectly. Insert the battery

as shown on
battery cover 4 (Fig. C).
The battery is drained.| Insert a new battery.
When the product is turned on, the display shows „—-“ for 5 seconds (approx) & shows OFF for the next 3 seconds (approx), and then
the display turns off.| The ambient temperature is
too low (or) too high.| Turn off the product. Move to the place, where the ambient temperature can be reached within the mentioned range.
Allow the product to stabilize the working ambient temperature range for minimum 30 minutes. Then, turn on the product. The product should function normally.
---|---|---
An incorrect temperature value is shown on the display.| Low battery.| Replace with a new battery
Did not allow about 30 minutes for
the product to acclimate to the environmental condition
after an ambient condition has been changed drastically.| Allow about 30 minutes for the product to acclimate to the environmental condition.
Not suitable measuring surface.| Change the measuring surface.

Maintenance and cleaning

  • Ensure that no water enters the product during cleaning!
  • Regularly clean the product with a dry, lint-free cloth.
  • If the product is very dirty, use a slightly damp cloth with a detergent.
  • Ensure no objects enter the opening for the infrared sensor 2. If necessary, only clean the opening with light compressed air.

Disposal

The packaging is made entirely of recyclable materials, which you may dispose of at local recycling facilities.
Observe the marking of the packaging materials for waste separation, which are marked with abbreviations (a) and numbers (b) with the following meaning: 1–7: plastics /
20–22: paper and fibreboard  80–98: composite materials.
The product and packaging materials are recyclable and disposed of them separately for better waste treatment. The Triman logo is valid in France only.
Contact your local refuse disposal authority for more details on how to dispose of your worn-out product.
To help protect the environment, please dispose of the product properly when it has reached the end of its useful life and not in household waste. Information on collection points and their opening hours can be obtained from your local authority.
Faulty or used batteries/rechargeable batteries must be recycled in accordance with Directive 2006/66/EC and its amendments. Please return the batteries/rechargeable batteries and/or the product to the available collection points.
Environmental damage through incorrect disposal of the batteries/rechargeable batteries!
Batteries/rechargeable batteries may not be disposed of with the usual domestic waste. They may contain toxic heavy metals and are subject to hazardous waste treatment rules and regulations. The chemical symbols for heavy metals are as follows: Cd = cadmium, Hg = mercury, Pb = lead. That is why you should dispose of used batteries /rechargeable batteries at a local collection point.

Warranty

The product has been manufactured to strict quality guidelines and meticulously examined before delivery. In the event of product defects, you have legal rights against the retailer of this product. Your legal rights are not limited in any way by our warranty detailed below. The warranty for this product is 3 years from the date of purchase. The warranty period begins on the date of purchase. Please keep the original sales receipt in a safe location. This document is required as your proof of purchase. Should this product show any fault in materials or manufacture within 3 years from the date of purchase, we will repair or replace it – at our choice – free of charge to you. This warranty becomes void if the product has been damaged, used, or maintained improperly. The warranty applies to defects in material or manufacture. This warranty does not cover product parts subject to normal wear, thus possibly considered consumables (e.g. batteries) or for damage to fragile parts, e.g. switches, rechargeable batteries or glass parts.
Warranty claim procedure
To ensure quick processing of your case, please observe the following instructions:
Please have the till receipt and the item number (IAN 374243_2104) available as proof of purchase.
You will find the item number on the rating plate, an engraving on the front page of the instructions for use (bottom left), or a sticker on the rear or bottom of the product.
If functional or other defects occur, please contact the service department listed either by telephone or by e-mail.
You can return a defective product to us free of charge to the service address that will be provided to you. Ensure that you enclose the proof of purchase (till receipt) and information about what the defect is and when it occurred.
Service

Service Great Britain
Tel.: 08000569216
E-Mail: owim@lidl.co.uk
OWIM GmbH & Co. KG
Stiftsbergstraße 1
74167 Neckarsulm
GERMANY
Model-No.: HG05546
Version: 12 / 2021
Last Information Update · Tilstand af information
Version des informations · Stand van
de informatie · Stand der Informationen:
08 / 2021 · Ident.-No.: HG05546082021-6
IAN 374243_2104

Documents / Resources

| PARKSIDE PTIA 1 Digital Laser Infrared Thermometer [pdf] Instruction Manual
PTIA 1, Digital Laser Infrared Thermometer, Laser Infrared Thermometer, Infrared Thermometer, Digital Thermometer, Thermometer, PTIA 1
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals