BEGA 85170 RGBW Performance Floodlight Instruction Manual

July 17, 2024
BEGA

85 170

85170 RGBW Performance Floodlight

Technical amendments reserved
Performance floodlight RGBW

Instructions for use

Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
The floodlight can be controlled by DALI colour light control (DT8, RGBWAF, xy, TC).

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver ”
Safety glass with optical structure
Silicone gasket
Reflector surface made of pure aluminium
BEGA Constant Optics®
Rotation range of floodlight 350°
Swivel range -30°/+95°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver® Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable(DT8, RGBWAF, xy, TC)
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control® Temporary thermal regulation to protect temperature- sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical impacts < 5 joule
– Conformity mark
Wind catching area: 0.028 m²
Weight: 3.0 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm). The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow ( ), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

Lamp
Module connected wattage ………………………..34.8 W
Luminaire connected wattage ……………………….. 38.6 W
Rated temperature ………………………..tamax= 25 °C
Ambient temperature ………………………..tamax = 30 °C
Module designation ………………………..LED-1160/RGBW
Colour temperature of the white LED ……………………….. 4000 K
Luminaire luminous flux  ……………………….. 2076 lm
Luminaire luminous efficiency ……………………….. 53,8 lm / W
Lighting technology
Symmetrical wide beam light distribution
Half beam angle 50°
For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Maintenance

The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
Replace
LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.

Accessories

71 291 …………………………..Optical filter flat beam
71 333 ………………………….. Shield
71 338 …………………………..Cylindrical shield
70 214 …………………………..Pole cap for pole ø 48 mm
70 248………………………….. Pole cap for pole ø 60 mm
70 245………………………….. Mounting box
70 252………………………….. General fastener
70 280………………………….. Tube clamp G½
70 283………………………….. Screw clamp
70 379………………………….. Cross beam G½
70 889………………………….. Tension belt
For the accessories a separate instructions for use can be provided upon request.

Spares

Trim ring graphite with glass 25 000 283
Trim ring silver with glass 25 000 284
LED power supply unit DEV-0357/200
LED module LED-1160/RGBW
Reflector 76 002 009
Gasket housing 83 001 579
Gasket trim ring 83 002 306

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals