WARNING BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY.
WARNING: Risk of electric shock and serious injury. SHUT OFF BREAKER AT PANEL BEFORE INSTALLING.

CAUTION:

  • Risk of fire or electric shock. Check for damage to luminaire, electrical, and structural parts before installation.
  • This luminaire is intended for installation by qualified electrician only.
  • Disconnect electrical power to circuit before installation or maintenance.

1.0 INSTALLATION INSTRUCTIONS – OPTICAL CONTROL ACCESSORIES

2. INSTALLATION INSTRUCTIONS – SLIP FITTER MOUNTING

2.1  INSTALLATION INSTRUCTIONS – SLIP FITTER MOUNTING FOR ROUND POLE

Step 1: Drill holes on the square pole corresponding to the holes on the square bar adapter, and use the bolt and nut plate to fix the fixture to the Adapter ghtly.
Step 2: Connect the AC wire of the fixture and ghten the water-proof gasket and cover plate on the square bar adapter by screws, then power on.

Step 1: Drill holes on the round pole corresponding to the holes on the Round bar adapter, and use the bolt and nut plate to fix the fixture to the Adapter ghtly.
Step 2: Connect the AC wire of the fixture and ghten the water-proof gasket and cover plate on the square bar adapter by screws, then power on.

2.2 INSTALLATION INSTRUCTIONS – TRUNNION MOUNTING
2.3 INSTALLATION INSTRUCTIONS – ARM MOUNTING FOR SQUARE POLE
2.4 INSTALLATION INSTRUCTIONS – DESCRIPTION OF PHOTOCELL INSTALLATION

ACCESSORIES

2.5 INSTALLATION INSTRUCTIONS – ARM WITH MICROWAVE SENSOR

Step 1: Check if the work voltage of microwave sensor, photocell and shor ng cap conform to input voltage, then turn on to test the microwave sensor.

Step 2: If it didn’t work, open the waterproof box and set the microwave sensor to work, lock the box a er completed. (A en on put in the water-proof gasket before lock)

2.6 INSTALLATION INSTRUCTIONS – ARM WITH MICROWAVE SENSOR

Replace shor ng Cap with microwave sensor by Photocell with microwave sensor
Step 3: Check if the work voltage of microwave sensor and photocell conform to input voltage, then take off the shor ng cap.

Step 4: Connect the photocell with the base.

2.7 INSTALLATION INSTRUCTIONS – DESCRIPTION OF PHOTOCELL INSTALLATION

ACCESSORIES

2 .8 INSTALLATION INSTRUCTIONS – WIRING DRAWING FOR PHOTOCELL

3.0 INSTALLATION INSTRUCTIONS – ARM WITH PHOTOCELL INSTALLATION

3.1 INSTALLATION INSTRUCTIONS – WIRING DRAWING FOR PHOTOCELL & MICROWAVE

MOTION SENSOR

Miami, FL USA – info@jademar.com T: 305.640.0465 – F: 305.640.0468
WWW.JADEMAR.COM

http://www.jademar.com

Revised 03/2024