JADEMAR LIGHTING PFL-G2 Floodlight Generation 2 Instruction Manual
- June 5, 2024
- JADEMAR LIGHTING
Table of Contents
JADEMAR LIGHTING PFL-G2 Floodlight Generation 2
INSTALLATION INSTRUCTIONS
Make electrical and grounded connections in accordance with the national electrical code and any applicable code. Always turn off the power supply before installaon. This product must be installed in accordance with the applicable installaon code by a qualified electrician who is familiar with the construction and operaon of the product and the hazards involved.
- Risk of fire or electric shock. Fixture installed on requires knowledge of luminaires electrical systems. If not qualified, DO NOT an empty installed on. Contact a qualified electrician.
- Risk of fire or electric shock. Suitable for wet locations. Always turn off the power supply before
- installa on.
- Risk of fire or electric shock. Suitable for non-insulated surfaces and frames. DO NOT cover fixture with insula on the liner or similar material.
- DO NOT install fixture on the unstable, loose or easily breakable surface.
- DO NOT exert force on the surface of the fixture.
INTRODUCTION
This LED Floodlight uses the latest in solid-state light technology for long life, low maintenance, and high efficiency. The same as traditional HID light ng. 80~400W there are five different, suitable for various occasions.
WARNING:
- To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes.
- All the products can not be installed on woods.
- To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes.
- All the products can not be installed on woods.
- To avoid explosion: Make sure the supply voltage is the same as the rated luminaire voltage.
- Do not install where the marked opera ng temperatures exceed on the temperature of the hazardous atmosphere.
- Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
- Keep lens ghtly closed when in opera on.
- For supply connec ons use wire rated for at least 90°C
MODEL| INPUT VOLTAGE| WATTAGE| INPUT CURRENT| MAXIMUM WEIGHT
---|---|---|---|---
PFL-100W| 100-277VAC| 100W| 1.1A| 6.62LBS
PFL-100W-H| 277-480VAC| 100W| 0.5A| 7.15LBS
PFL-150W| 100-277VAC| 150W| 2A| 7.19LBS
PFL-150W-H| 277-480VAC| 150W| 0.8A| 7.63LBS
PFL-230W| 100-277VAC| 230W| 2.7A| 8.26LBS
PFL-230W-H| 277-480VAC| 230W| 1.8A| 8.67LBS
PFL-300W| 100-277VAC| 300W| 4A| 11.17LBS
PFL-300W-H| 277-480VAC| 300W| 1.5A| 12.22LBS
PFL-400W| 100-277VAC| 400W| 4.8A| 14.13LBS
PFL-400W-H| 277-480VAC| 400W| 1.95A| 15LBS
Installation Steps:
Refer to the following diagram when you install the fixture. Five installations on methods, directly fix to the, mounting surface or fix to a post with a knuckle.
- Directly fix to the mounting surface
- Mounting with a Slip filter
- Mounting with Slip filter and Wall-mounted adapter
- Mounting with Arm
- Wall-mounted installation
The mounting method of the straight arm is added to a wall-mounted fixing plate, and the fixing plate is mounted on the wall, and the fixing plate is fixed by a nut.
Positions for Sensor and Photocell installed
LED DRIVER & PHOTOCELL
WIRING DIAGRAM FOR PLUG-IN SENSOR POLE INSTALLATION WIRING
Connect the lamp pole intemal cable with the luminaire cable. The neutral line is connected to the neutral line. The ground line is grounded, and the live line is connected to the fire line.
After installation,
please do fne following: Check whether the lighting fixture is firmly fixed.
Check whether wires are connected correctly. Lastly, turn on the power, and
check if the lighting fixture works well. if not. please turn off the power
and contact with a local dealer