JADEMAR LIGHTING JFL-PS 90W Floodlight Instruction Manual
- June 9, 2024
- JADEMAR LIGHTING
Table of Contents
- WIRING DIAGRAM
- INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – TRUNNION MOUNTING
- INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – YOKE MOUNTING
- INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – UNIVERSAL BRACKET
- COLOR TEMPERATURE ADJUSTMENT INSTRUCTIONS
- WARNING/AVERTISSEMENT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
JADEMAR LIGHTING JFL-PS 90W Floodlight Instruction Manual
WARNINGS
- DO NOT USE AN ELECTRIC GENERATOR TO TEST THE LAMP.
- Please abide by country, regional and local law and regulaons when installing this fixture.
- Please turn off the power before installaon or maintenance.
- Proper earth grounding is required to ensure safety.
- To avoid possibility of electrical shock or fire, the installer must be a licensed electrician.
- Please wear gloves to avoid injury before installaon.
- During or aer installaon, if there are situaons such as smoke, fire in the wires or lamps, please turn off the power immediately and nofy relevant personnel for an overhaul.
- This light can be used for outdoor installaon.
- Please check if there is any damage during shipping. If so, please contact manufacturer mely.
- Please read the installaon instrucon carefully to check whether all the accessories are complete. Aer confirmaon, then install the fixture according to installaon steps.
WIRING DIAGRAM
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – TRUNNION MOUNTING
Step 1: Pass the input wire of the fixture through the bracket (Figure
4);
Step 2: Fix the bracket (Figure 5).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – YOKE MOUNTING
Step 1: Take out the bracket; ghten the screws, and fix the bracket on the fixture (Figure 6).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – UNIVERSAL BRACKET
MOUNTING
Step 1: Separate the bracket with tool (Figure 13);
Step 2: Pass the input wire of the fixture through the bracket (Figure
14);
Step 3: Pass the input wire through the bracket and lock the bracket
(Figure 15).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – YOKE MOUNT TO UNIVERSAL BRACKET MOUNT
Step 1: Take out the bracket; Tighten the screws, fix the bracket on the
fixture (Figure 24);
Step 2: Separate the bracket with tool (Figure 25);
Step 3: Pass the input wire of the fixture through the bracket (Figure
26);
Step 4: Pass the input wire through the bracket and lock the bracket
(Figure 27)..
INSTALLATION INSTRUCTIONS OF LED LAMPS – TRUNNION MOUNTING
Step 1: Drill holes on the wall as shown (Figure 30);
Step 2: Knock the expansion bolts into the wall (Figure 31);
Step 3: Fix the fixture to the bracket and ghten the screws; connect the
wires properly and put them into juncon box (Figure 32).
Noce: Adjustable angle is 0~+/-90° (Figure 32)
INSTALLATION INSTRUCTIONS OF LED LAMPS – YOKE MOUNTING
Step 1: Drill holes on the wall as shown (Figure 33);
Step 2: Knock the expansion bolts into the wall (Figure 34);
Step 3: Fix the fixture to the bracket and ghten the screws; connect the
wires properly and put them into juncon box (Figure 35).
Noce: Adjustable angle is 0~+/-180° (Figure 35)
INSTALLATION INSTRUCTIONS OF LED LAMPS – UNIVERSAL BRACKET 4 IN 1
Step 1: Remove the spare parts, the remaining parts as shown in Figure
39;
Step 2: Loosen the 4 locking bolts on the slip fier, connect the wires
correctly and put the wire into pole. Then fasten the locking bolts between
slip fier and the pole (Figure 40);
Step 3: Loosen the fixing bolts and adjusng bolts, adjust fixture angle
as per actual demands. Tighten adjusng bolt and fixing bolts aer the angle is
confirmed (Figure 40).
Noce: Adjustable angle is 0~+/-90° (Figure 40)
INSTALLATION INSTRUCTIONS OF LED LAMPS – UNIVERSAL BRACKET 4 IN 1
Step 1: Change the rubber plug on the Installaon bar to the A&DM bracket
(Figure 41);
Step 2: Fix the DM bracket to the square pole by bolt. Connect the power
cable with pole cable, make sure good protecon on wire connecon, and put the
wire in the DM bracket; close the side lid and ghten it, (Figure 42) then
finish installaon.
Noce: Adjustable angle is 0~+/-90° (Figure 42)
Noce: Round pole should be with adapng plate (Figure 43).
Aenon: When the photocell funcon is required, photocell should be installed on the back of lamp; When it’s not required, shorng cap should be installed on the back of lamp (Figure 44)
COLOR TEMPERATURE ADJUSTMENT INSTRUCTIONS
Standard wire:
L/live wire: Black\Brown;
N/null wire: White\Blue;
Ground wire: Green\Yellow-green.
Step 1: Find the switch to adjust CCT (Figure 45);
Step 2: Light up the lamp, push aside the fixing piece to show the black
buon, and adjust the color temperature by pressing the black buon
(Figure46);
Step 3: Once the color temperature is confirmed, return the fixing piece
back to the original posion and ghten the screw to lock the fixing piece
(Figure 47).
WARNING/AVERTISSEMENT
MIN 90 °C SUPPLY CONDUCTOR
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
WARNINGS
- DO NOT USE AN ELECTRIC GENERATOR TO TEST THE LAMP.
- Please abide by country, regional and local law and regulaons when installing this fixture.
- Please turn off the power before installaon or maintenance.
- Proper earth grounding is required to ensure safety.
- To avoid possibility of electrical shock or fire, the installer must be a licensed electrician.
- Please wear gloves to avoid injury before installaon.
- During or aer installaon, if there are situaons such as smoke, fire in the wires or lamps, please turn off the power immediately and nofy relevant personnel for an overhaul.
- This light can be used for outdoor installaon.
- Please check if there is any damage during shipping. If so, please contact manufacturer mely.
- Please read the installaon instrucon carefully to check whether all the accessories are complete. Aer confirmaon, then install the fixture according to installaon steps.
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – TRUNNION MOUNTING
Step 1: Pass the input wire of the fixture through the bracket (Figure
1);
Step 2: Fix the bracket (Figure 2).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – YOKE MOUNTING
Step 1: Take out the bracket; ghten the screws, and fix the bracket on the fixture (Figure 3).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – UNIVERSAL BRACKET MOUNTING
Step 1: Separate the bracket with tool (Figure 4);
Step 2: Pass the input wire of the fixture through the bracket (Figure
5)
Step 3: Pass the input wire through the bracket and lock the bracket
(Figure6).
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – SLIP FITTER TO UNIVERSAL BRACKET MOUNTING
Step 1: Separate the bracket with tool (Figure 10);
Step 2: Pass the input wire of the fixture through the bracket (Figure
11);
Step 3: Pass the input wire through the bracket and lock the bracket
(Figure12).
INSTALLATION INSTRUCTIONS OF LED LAMPS – TRUNNION MOUNT TO WALL PLATE
Step 1: Drill holes on the wall as shown (Figure 13);
Step 2: Knock the expansion bolts into the wall (Figure 14);
Step 3: Fix the fixture to the bracket and ghten the screws; connect the
wires properly and put them into juncon box (Figure 15).
Noce: Adjustable angle is 0~+/-90° (Figure 15)
INSTALLATION INSTRUCTIONS OF LED LAMPS – YOKE MOUNT TO WALL PLATE
Step 1: Drill holes on the wall as shown (Figure 16);
Step 2: Knock the expansion bolts into the wall (Figure 17);
Step 3: Fix the fixture to the bracket and ghten the screws; connect the
wires property and put them into juncon box (Figure 18).
Noce: Adjustable angle is 0-+/-180° (Figure 18)
INSTALLATION INSTRUCTIONS OF LED LAMPS – UNIVERSAL BRACKET
Step 1: Remove the spare parts, the remaining parts as shown in Figure
22:
Step 2: Loosen the 4 locking bolts on the slip fier, connect the wires
correctly and put the wire into pole. Then fasten the locking bolts between
slip fier and the pole (Figure 23);
Step 3: Loosen the fixing bolts and adjusng bolts, adjust fixture angle
as per actual demands. Tighten adjusng bolt and fixing bolts aer the angle is
confirmed (Figure 23).
Noce: Adjustable angle is 0~+/-90° (Figure 23)
INSTALLATION INSTRUCTIONS OF LED LAMPS – UNIVERSAL BRACKET SQUARE & ROUND POLE
Step 1: Change the rubber plug on the Installaon bar to the A&DM bracket
(Figure 24);
Step 2: Fix the DM bracket to the square pole by bolt. Connect the power
cable with pole cable, make sure good protecon on wire connecon, and put the
wire in the DM bracket; close the side lid and ghten it, (figure 25) then
finish installaon.
Noce: Adjustable angle is 0~+/-90° (Figure 25)
Noce: Round pole should be with adapng plate (Figure 26).
Aenon: When the photocell funcon is required, photocell should be installed on the back of lamp; When it’s not required, shorng cap should be installed on the back of lamp (Figure 27)
COLOR TEMPERATURE ADJUSTMENT INSTRUCTIONS
Step 1: Find the switch to adjust CCT (Figure 28);
Step 2: Light up the lamp, push aside the fixing piece to show the black
buon, and adjust the color temperature by pressing the black buon
(Figure29);
Step 3: Once the color temperature is confirmed, return the fixing piece
back to the original posion and ghten the screw to lock the fixing piece
(Figure 30).
Waage Adjustable Instrucon
- Unscrew the plug with screwdriver or coin (Figure 31)
- Adjust the waage adjustable dial switch to different gear which match to corresponding waage (Figure 31) First gear please tum to E7, 2nd gear (full power) please turn to I, 1st to 2nd gear refer to lower waage to full waage.
- Please re-install the plug aer adjustment.
Note: Please turn off the power before adjust waage.
WARNING/AVERTISSEMENT:
MIN 90 °C SUPPLY CONDUCTORS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
WARNINGS
- DO NOT USE AN ELECTRIC GENERATOR TO TEST THE LAMP.
- Please abide by country, regional and local law and regulaons when installing this fixture.
- Please turn off the power before installaon or maintenance.
- Proper earth grounding is required to ensure safety.
- To avoid possibility of electrical shock or fire, the installer must be a licensed electrician.
- Please wear gloves to avoid injury before installaon.
- During or aer installaon, if there are situaons such as smoke, fire in the wires or lamps, please turn off the power immediately and nofy relevant personnel for an overhaul.
- This light can be used for outdoor installaon.
- Please check if there is any damage during shipping. If so, please contact manufacturer mely.
- Please read the installaon instrucon carefully to check whether all the accessories are complete. Aer confirmaon, then install the fixture according to installaon steps
WIRING DIAGRAM
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – TRUNNION TO YOKE
MOUNTING
Step 1: Put the input wire of the light across the bracket. (Figure
7)
Step 2: Fix the bracket. (Figure 8)
Step 3: Take out the bracket; let the input wire go through the cover or
the back cover of the light, then fix the cover and ghten the screws, fix the
bracket on the fixture. (Figure 9)
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS -= UNIVERSAL BRACKET
Step 1: Separate the bracket with tool. (Figure 10)
Step 2: Put input wire of the light across the bracket. (Figure 11)
Step 3: Let input wire go through the bracket and lock the bracket.
(Figure12)
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – TRUNNION TO WALL MOUNT
Step 1: Drill holes on the wall as shown. (Figure 16)
Step 2; Knock the expansion bolts into the wall (Figure 17)
Step 3: Connect the fixture to the bracket and ghten the screws; connect
the wires properly and put them into juncon box. (Figure 18)
Noce: Adjustable angle is 0~+/-90* (Figure 18)
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – YOKE MOUNTING TO WALL PLATE
Step 1: Drill holes on the wall as shown. (Figure 19)
Step 2: Knock the expansion bolts into the wall (Figure 20)
Step 3: Connect the fixture to the bracket and ghten the screws; connect
the wires properly and put them into juncon box (Figure 21)
Noce: Adjustable angle is 0-+/-90* (Figure 21)
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – UNIVERSAL BRACKET
Step 1: Remove the spare parts, the remaining parts such as (Figure 22)
Step 2: Loosen the 4 locking bolts on the slip fier, connect the wire
correctly and put the wire into pole. Then fasten the locking bolts between
slip fier and the pole. (Figure 23)
Step 3: Loosen the fixing bolts and adjusng bolts, align the fixture to
required angle. Tighten adjusng bolt and fixing bolts aer the angle is
confirmed. (Figure 23)
Noce: Adjustable angle is 0-+/-90° (Figure 23)
INSTALLATION INSTRUCTIONS FOR DIFFERENT BRACKETS – UNIVERSAL BRACKET SQUARE & ROUND POLE
Step 1: Change the rubber plug on the Installaon bar to the AM&DM
bracket. (Figure 24)
Step 2 : Fix the DM bracket to the square pole by bolt. Connect the power
cable with pole cable. Make sure good protecon on the wire connecon, and put
the wire in the DM bracket; close the side lid and ghten it, (figure 25) then
finish installaon.
Noce: Adjustable angle is O~+/-90° (Figure 25)
Noce: Round pole should be with adapng plate. (Figure 26)
NOTES
Aenon: When the photocell funcon is required, photocell should be
installed
on the back of lamp; When it’s not required, shorng cap should be installed on
the back of lamp (Figure 27)
Standard wire:
L/live wire; Black\Brown;
N/null wire: White Blue;
Ground wire: Green Yellow-green
Step 1. Waage Adjustable Instrucon Unscrew the plug with screwdriver or
coin Figure 28)
Step 2. Adjust the waage adjustable dial switch to different gear which
match to corresponding waage (Figure 28)
First gear please turn to 2nd gear please turn 3rd gear please turn to 4th
gear (full power) please. turn 1st to 4th gear refer to lower waage to full
waage
Step 3. Please re-install the plug aer adjustment.
Note: Please turn off the power before adjusng waage
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>