JADEMAR JFL-HAZ Series Hazardous Location Floodlight
PRODUCT DESCRIPTION
The Jademar JFL-HAZ series of Hazardous Loca on Floodlights are cer fied for use in the most challenging of loca ons with Class I Division 2 Group A, B, C, and D Classifica ons.
HAZARDOUS LOCATION CLASSIFICATIONS
- Class I: A hazardous loca on in which flammable gases or vapors may be present in the air insufficient quan es to be explosive or ignitable. Division 2: Abnormal condi ons, where ignitable concentra ons of flammable gases, vapors or liquids are not likely to exist under normal opera ng condi ons.
- Groups A – D: The gases and vapors of Class 1 loca ons are broken into four groups by the Code: A, B, C, and D. These materials are grouped according to the igni on temperature of the substance, its explosion pressure, and other flammable characteris cs.
- Group A: The only substance in group A is acetylene because it is a gas with extremely high explosion pressures.
- Group B: This group includes hydrogen and other materials with similar characteris cs.
- Group C & D: The most usual Class 1 groups. They comprise the greatest percentage of all Class I hazardous loca ons.
- Group C: Found in Group D are many of the most common flammable substances such as butane, gasoline, natural gas and propane.
- ATEX Zone 1: A Zone 1 area is classified as a place in which an explosive atmosphere, consis ng of a mixture with air or flammable substances in the form of gas, vapor or mist is likely to occur in normal opera on occasionally.
- ATEX Zone 2: The defini on of Zone 2 is a hazardous area classified as an atmosphere where a mixture of air and flammable substances in the form of gas, vapor or mist is not likely to occur in normal opera on, but if it does occur, will persist for a short period only.
CERTIFICATIONS AND COMPLIANCE
PERFORMANCE SUMMARY
Input Power: | 30W / 100W / 180W |
---|---|
Efficacy: | up to 115 lm/W |
CCT: | 2700K / 4000K / 5700K |
Input Voltage: | 100-277VAC |
Surge Protection: | IEC/EN 61000-4-5 |
Certifications & Compliance | Class I Division 2 Group A, B, C,D |
UL / ISO 14001 / ISO 9001
Warranty:| 10 Years
MOUNTING OPTIONS
APPLICATIONS
- Petroleum Refineries
- Aircraft Hangers
- Dry Cleaning Plants
- U lity Gas Plants
- Gas & Diesel Sta ons
Informa on contained herein is subject to change without no ce. Values are nominal. Revised 08/2022
SPECIFICATION SUBMITTAL DETAIL
Project Name/Type: | Date: | |
---|---|---|
Catalog/Part #: |
JFL-HAZ HAZARDOUS LOCATION FLOODLIGHT (CLASS I DIVISION 2 GROUP A, B, C, D)
ORDERING INFORMATION / EXAMPLE: JFL-HAZ-30W-30K-YW-AWB
| | | | | | |
---|---|---|---|---|---|---|---
Product Series| Wattage| Input Voltage| CCT| Light
Distribution| Finish| Mounting Options| Power Cord Options
JFL-HAZ
| ****
30W
100W
185W
| ****
Blank
(100-277VAC)
H
(480VAC Driver)
| ****
30K (3000K)
40K (4000K)
50K (5000K)
| ****
Blank
(120° Beam Angle)
| ****
YW (Yellow) GR (Gray)
| UB
(U-Bracket Mount)
EH
(Eye-Hook Mount)
AWB
(Adjustable Wall Mount Bracket)
ST
(Stention Mount Bracket)
| ****
Blank
(6FT Power Cord Included)
**PWCx-C***
(Additional Power Cord Length)
- Specify Length ( x ) and Color ( C )
FIELD INSTALLED OPTIONS
JFL-HAZ-REC- 100W | Recessed Frame for 100W |
---|---|
JFL-HAZ-REC- 185W | Recessed Frame for 185W |
LUMEN PERFORMANCE AND ELECTRICAL DATA
Product Number| JFL-HAZ- 30W| JFL-HAZ- 100W| JFL-
HAZ- 185W
---|---|---|---
Maximum Dimensions| 7.87″ x 7.87 x 10.63″| 11.81″ x 11.81″ x 6.89″|
15.75″ x 15.75″ x 7.29″
Nominal watts| 30W| 100W| 185W
Average Nominal Efficacy (lm/W)| 115| 115| 115
Average Lumen Output (lm)| 3,450| 11,500| 20,700
Max Weight| 8.9 lbs.| 16.6 lbs.| 26.5 lbs.
Input Voltage| 100-277VAC
CCT| 2700K / 4000K / 5700K
CRI| >73
THD @ 120VAC| <10%
Power Factor| >0.98
Surge Protection| IEC/EN 61000-4-5
Construction| Die Cast Aluminum / Tempered Glass Lens
Rated Lifetime| Rated Life of 100,000+ Hrs
Ambient Working Temp| (-30 ºC to +50 ºC) -22°F to 122°F
Certifications & Compliance
| CLASS I DIVISION 2 GROUP A, B, C, D / UL844 ISO 14001 / ISO 9001/ UL 1598 &
ANSI/UL 8750
Limited Warranty| 10 Yrs
MOUNTING INSTALLATION OPTIONS
Miami, FL USA – info@jademar.com T: 305.640.0465 – F: 305.640.0468 WWW.JADEMAR.COM
Informa on contained herein is subject to change without no ce. Values are nominal. Revised 08/2022