profi-pumpe Trio-Basalt Garden Fountain with LED Light Instruction Manual
- July 14, 2024
- profi-Pumpe
Table of Contents
- profi-pumpe Trio-Basalt Garden Fountain with LED Light
- Product Usage Instructions
- INTRODUCTION
- IN GENERAL
- ASSEMBLY INSTRUCTIONS
- MAINTENANCE:
- SECURITY TIPS
- GUARANTEE REGULATIONS
- RECOGNISING AND REPAIRING OF MISTAKES
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
profi-pumpe Trio-Basalt Garden Fountain with LED Light
Specifications
- Product Name: Garden Fountain with LED Light
- Model: TRIO-BASALT
- Version: 24.04
- Website: www.profi-pumpe.de
Product Usage Instructions
Safety Instructions and Warnings
Please read the user manual before using the device. Ensure to pull the
power plug when not in use. Pay attention to warning signs and electrical
voltage.
Introduction
Congratulations on purchasing our garden fountain. Our priority is
functional security and operational safety.
Assembly Instructions
- Remove all parts from the packaging and place them on a flat surface.
- LEDs are pre-assembled in the fountain body.
- Connect each cable plug to an LED and tighten closing caps.
- Connect the power cable to the adapter.
- Fill the reservoir with clean water, preferably distilled water to reduce mineral deposits.
- Ensure all connections are properly connected without kinks in cables or water hose.
- Plug the power supply into the electrical outlet to start water flow and activate pump & LED lighting.
- Place the pump at the bottom of the fountain, ensuring it is completely submerged in water to avoid damage.
Adjust Valves for Water Flow
To achieve an even flow of water, open the valves on the distributor
accordingly.
FAQ
Q: What should I do if there is uneven water distribution or splashes in
the fountain area?
A: During the first start-up, check and adjust the level accuracy of the
fountain and adjust the water flow as needed.
GARDEN FOUNTAIN with LED light
Version 24.04
OPERATING INSTRUCTIONS
TRIO-BASALT
Technical changes, misprints and mistakes reserved! Newest information about
our products can be found online Technische Änderungen, Druckfehler und
Irrtümer vorbehalten! Aktuelle Informationen zu unseren Produkten finden Sie
auf: https://www.profi-pumpe.de
INTRODUCTION
We would like to congratulate you on the purchase of our garden fountain. We appreciate your trust. That‘s why functional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the pump. Failure to follow the instructions and safety precautions can
result in injury or property damage.
Please keep this manual with the instructions and safety instructions
carefully in order to at any time you can restore them. Please always download
the latest version of the user manual of www.profi-pumpe.de under „downloads“.
This shall always prevail.
IN GENERAL
The Garden fountains are high-quality fountain pump systems for outdoor or indoor use. The perfect eye-catcher.
- It‘s recommended NOT to conduct yourself technical modifications. First, it is not certain whether these changes are technically correct and, secondly, because no guarantee can be granted.
- Transport damages are immediately to be reported to the package distributor and to us in written form. Failure to give timely notice to the shipping company, and are therefore rejected your claims from the transport company, so we can not accept these claims as well. In your legal obligation to cooperate to minimize damage, we point out expressly herewith.
ASSEMBLY INSTRUCTIONS
- Remove all parts carefully from the packaging and place them on a flat surface.
- The LEDs are pre-assembled in the fountain body.
- Depending on the model, the connecting cable has one or more cable plugs for connecting the LEDs.
- Connect each cable plug to an LED.
- Tighten the closing caps on the LED connectors.
- Connect the power cable to the adapter.
- Fill clean water into the reservoir. Note: Distilled water is recommended to reduce mineral deposits and bacteria buildup.
- Before turning on the pump, make sure all connections are properly connected. There should be no kinks in the cables or waterhose.
- Now plug the power supply into the electrical outlet. If installed correctly, the water will begin to flow. Note: When connected to the power supply, the pump and LED lighting are switched on.
When the power is disconnected, the pump and LED lighting are switched off.
Please note that some water may splash out of the well when the pump starts up for the first time. If necessary, move the water quantity regulator on the pump in the “-” direction.
- When all connections are complete, place the pump at the bottom of the fountain. Route the power cable to the outside.
- Fill the fountain with water. The pump must be completely submerged in water, otherwise the pump will be damaged.
IMPORTANT!
Problem: Uneven water distribution or water splashes in the fountain
area.
Remedy: During the first start-up, uneven water distribution may occur.
In such cases, we recommend that you check and adjust the level accuracy of
the fountain and adjust the water flow (see page 12).
ADJUST VALVES FOR WATER FLOW
For an even flow of water, the valves on the distributor should be opened as
follows:
- Longest hose (left, see fig.) should be fully open
- Middle hose should have the valve 1/3 open
- Shortest hose should be 2/3 open
MAINTENANCE:
- Keep the fountain in good working condition by cleaning it and changing the water every 3 days. Using distilled or purified water will give the best performance.
- If debris is caught in the intake vents of the pump, disconnect the pump from any power sources and rinse the pump under clean running water.
- Before storing the pump in winter it is absolutely important to rinse it with clean water. Any dirt particles remaining in the pump will dry out on the the pump shaft during the time of storage and cause irreparable damage.
Frost
Frost can cause damage to the garden fountain and pump. If there is a risk of
frost, the garden fountain and the pump must be emptied, rinsed with clean
water and stored in a dry place. Then you will enjoy it for a very long time!
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Observe water temperature of max. 35°C
- The mains plug must be disconnected before carrying out any work on the garden foun-tain
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross section narrowing
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test the well for sufficient flowing water (danger of dry running)
- The pump must be protected by a residual current circuit breaker with a tripping current of 30 mA.
- The electrical connection must always be carried out by an authorized specialist.
- The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
- Cleaning and maintenance must not be carried out by children without supervision.
- Under certain circumstances, it is possible that contamination of the water may occur due to lubricants flowing out.
THE MANUFACTURER EXPLAINS
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this manual.
- To reject every responsibility for the damages which originate from the improper use of the device.
GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In
these cases we take the replacement or repair of the device. Shipping costs
shall be borne by our company, except as required by law. Please report the
warranty on our service platform https://www.profi-pumpe.de/information.php.
We will inform you how to proceed with case-related. Returns please sufficient
postage. Unfortunately not prepaid returns can not be accepted because they
are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by self fault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|---|---|
Pump does not start | No electricity | Check electrical connections |
Defective pump | Replace pump |
Pump runs but no water is en- couraged
| Hose connections systems have a leak| Check hose connection systems
Pump could have a leak| Check pump for moisture damage
Coarsening or fountain nozzles dirty| Disassemble and clean the tube and the
fountain nozzle
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability
Act, which are caused by our units if no changes were made to the equipment.
If repairs are carried out by our authorized service, we are only liable if
original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash
bin, are not permitted to be disposed in your household garbage. We are
registered at the
German registration department EAR under the WEEE-No. DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point
of electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies
that the product named overleaf, namely TRIO-BASALT as placed on the market,
complies with the relevant provisions listed below, the relevant EU harmonised
directives and the EU standard for safety. This declaration of conformity
applies insofar as no modifications are made to the product. The sole
responsibility for issuing this declaration of conformity lies with the
manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
- EN 55014-1:2006+A1+A2
- EN55014-2:2015
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 61558-1:2005+A1
- EN 61558-2:2009
- ZEK01.4-08/11.2011
- Signed for and on behalf of:
- Amur S.à r.l.
- Remich, 03.04.2024
References
- Amur
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>