Trudian Digital Intelligent Building Video Intercom System Linux System Outdoor Station User Manual
- July 16, 2024
- Trudian
Table of Contents
Trudian Digital Intelligent Building Video Intercom System Linux System Outdoor Station
Introduction
Welcome to choose Our Building Video Intercom Products!
Our product is designed using the most advanced electronic communication
technology available today and manufactured with superior SMT technology. It
has undergone rigorous testing and inspection under a strict quality assurance
system. It features high integration, high reliability, and high cost-
performance, making it a trustworthy security intercom product.
Requires 12V DC; do not exceed this voltage or reverse the polarity.
The device contains sensitive electronic components and should be protected
from moisture, water, and high temperatures.
The device includes an LCD display panel, which should not be pressed with
sharp objects or subjected to excessive force.
The appearance, functions, and interface of the product may differ from the
actual device. The actual product should be used as the reference.
Video Intercom
Calling the Indoor Monitor
When the device is on the main interface, visitors can enter the room number
to call.
For example, to call “Building 2, Unit 3, Room 0101 in Zone 1”, enter 101 or
0101 on the unit outdoor station, or 0102030101 or 102030101 on the community
outdoor station.
Calling the Mobile App (Optional)
When a call comes in from the outdoor station and the indoor monitor does not
answer within 25 seconds, the system forwards the call to the resident’s bound
mobile app. If there is no indoor monitor, the call goes directly to the
mobile app. Once one mobile device answers, other devices will be
disconnected. The mobile app shows the current caller’s image and allows
screenshot and door unlocking.
Calling the Management Center
Follow the on-screen prompts and press “#” + “4” on the keyboard to enter the
property management call interface. Use “2” and “8” to switch left and right,
select “Call Management Center” or “Call Security Extension”, and press “#” to
confirm.
Unlock
Indoor Monitor Unlock
When calling or speaking with the resident, the resident can remotely
unlock the door through the indoor unit. The outdoor station will display “The
door is opened” and provide a voice prompt.
Mobile App Unlock (Optional Feature)
When calling or speaking with the resident, the resident can remotely
unlock the door through the mobile app. The outdoor station will display “The
door is opened” and provide a voice prompt.
Management Center Unlock
When calling the management center or security extension, remote unlocking
can be performed. The outdoor station will display “The door is opened” and
provide a voice prompt.
Password Unlock
Password unlocking includes public and user passwords. Public (User) hijack
password and public (user) unlock password are auto-generated in reverse order
and do not require setting.
Public (User) Password Unlock
Default is disabled and needs to be enabled by property personnel via
engineering settings. If setting a user password, the resident must also
configure it on the indoor monitor for it to be used.
Usage: Follow on-screen instructions, press “#” + “2” to enter “Password
Unlocking” screen, navigate with “2” and “8” to select public password
unlocking, press “#” to confirm, and enter the public password (user password
unlocking, press “#” to confirm, enter room number, and enter user password) .
If correct, the door unlocks and a snapshot is taken and uploaded to the
management center. If incorrect, an error message is displayed and a snapshot
is taken.
Public (User) Hijack Password Unlock
The public (User) hijacking password is the reverse of the public (User)
unlock password. It is auto-generated when the public unlock password is set
(the user sets their unlock password) .
Note: The public (User) hijacking password must be different from the public
(user) unlock password and is only active when the public (user) unlock
password is enabled. For example, if the public (user) unlock password is
123456, the public (user) hijacking password will be 654321. Using the public
(user) hijacking password triggers an alarm to the management center and
security.
Face Recognition Unlock (Optional)
Face Registration
-
On Device: Property personnel need to enable “Face Recognition
Management” -> “Face Recognition Registration” in engineering settings.
Follow prompts to enter room number and bind a phone number. -
Mobile App: Open Trudian Cloud app, navigate to “More Services” -> “Face Management” -> “Register Face” and follow prompts.
-
Management Center – Photo Upload: Access “Face Management”, select room number, enter face details, upload three photos.
-
Management Center – Camera Capture: Access “Face Management”, select room number, enter face details, capture three photos.
Face Unlock
When face recognition is enabled, the door station uses infrared or
microwave sensors to wake up and recognize the face in sleep mode, or manually
enter the unlock screen and press “#” + “1” to start face recognition.
QR Code Unlock (Optional)
Obtaining QR Code
Open the app, click “Authorize Code to Open”, generate a QR code.
QR Code Authorization
Click “Authorize to Visitor” under the QR code, set visitor identity, code
validity, and rules, then share via WeChat, QQ, or SMS.
QR Code Unlock
Press “#” + “3” to enter the QR code recognition screen and present a valid
QR code to the door station.
IC Card Unlock
Place a valid access card near the reader area to unlock.
Fingerprint Unlock (Optional)
Fingerprint Registration
Property personnel need to enable “Fingerprint Management” -> “Fingerprint
Registration” in engineering settings. Follow prompts to enter room number and
complete registration.
Fingerprint Unlock
Press a registered finger on the fingerprint sensor. If recognized, the
door station displays “The door is opened” with a voice prompt.
System Settings
System settings include address setting, admin password setting, unlock
password setting, password permissions, volume setting, unlock setting, door
sensor setting, language setting, date and time setting, system information,
card management, restore setting, access control setting, device serial
number, and 24 other settings.
Note: These settings must be operated by professional engineering
personnel. Users should not change these settings lightly.
To enter system settings: On the main screen, press “#” + “2”. Then enter the
six-digit admin password (default is 666666) to access the system settings
menu.
Address Settings
- Click “Address Settings” to set the building information.
- For example, to set the address for Building 2, Unit 1, Door Station 3 in Zone 1.
- After setting the address, you can either assign an IP address to the door station based on the room number configuration table or manually enter the IP address. The device will automatically restart upon successful configuration.
User Password
Press the “#” to toggle the switch. When enabled by the administrator,
users can set the unlock password via the indoor monitor for unlocking.
Serial Number Settings
The device serial number is a unique identifier set at the factory and
should not be modified.
Admin Password Settings
Administrators can change the admin password by entering the current
password (6 digits) and the new password twice (6 digits each). This allows
for easier management.
Password Unlock
Press the “#” key to toggle the switch. Enter the correct old public unlock
password to set a new one. If successful, the interface and voice prompt will
indicate success; otherwise, it will indicate failure.
Note: The default public unlocking password is 012345, and the default
hijacking password is 543210. If the public unlocking password is set to
666666 or 121121, it will match the hijacking password, violating the rules
and causing the setting to fail.
Volume Settings
Set the advertisement volume and ring volume. Press “4” to decrease the
volume and “6” to increase the volume.
Door Lock Settings
Set the unlock delay for the electric lock. The default unlock method is
power-on unlock with a 10-second delay. Users can customize this setting as
needed.
Access Control Permission Settings
Each unit has a unique access control number matching the “Access Control
Permission Settings” in the management center.
Access Control Permission Value: Must match the settings in the property
management terminal.
Access Control Sector and Password Settings
Sector: Matches the sector number (01-16) set by property when issuing the
access card.
Password: Matches the 12-digit password set by property.
Note: For easier management, use a unified sector and password for the entire
community. Settings can be done manually, with a management card, or via
management center software. Refer to the PC terminal user manual for details.
Access Control Server Settings
Factory set; do not modify. Used for retrieving cloud intercom server
address, port, and SIP account info. Each unit has a unique access control
number matching the “Access Control Permission Settings” in the management
center.
Door Sensor Settings
Set the door sensor status & delay. Default is disabled. Customize as
needed.
Tamper Settings
Toggle tamper protection with “#”. When enabled, an alarm will notify the
management center and security if the device is tampered with.
Card Management
Add Card
To add a card, select “Add Card,” enter the room number, and place the card on
the reader. The screen will then indicate success.
Delete Card
To delete a card, select “Delete Card” and place the card on the reader.
The screen will then indicate success.
Note: Multiple cards can be added or deleted. It’s recommended to manage
cards via the management center PC terminal.
Facial Recognition Management
Automatic Facial Recognition
Toggle facial recognition activation via microwave sensor. Press “#” to
toggle.
Liveness Detection
Enable liveness detection to prevent unauthorized access using photos, face
swaps, masks, obstructions, and screen captures. Toggle with “#”.
Liveness Detection Threshold
Adjust liveness threshold to determine pass rates. Real humans score close
to 1, non-humans close to 0. Adjust with “4” to decrease, “6” to increase. RGB
range: 0.6-0.99.
Recognition Model Threshold
Recommended identification threshold is 80 points. Increasing it reduces
false positives but may slow recognition. Adjust with “4” to decrease, “6” to
increase. Model range: 80-90.
Facial Recognition Registration
Enter the facial registration interface.
Facial Authorization
Enter the facial recognition authorization code to enable the feature on
the device.
Facial Recognition Information
View information such as license number, authorization code, and
authentication status.
Cloud Video Intercom (Optional)
Cloud Video Intercom
The administrator enables this feature. If the indoor unit is not answered
within 25 seconds, the call is forwarded to the resident’s mobile app. The
first phone to answer disconnects the others, displays the caller’s image, and
allows screenshots and door unlocking.
QR Code Unlock
Admin enables this feature. Residents and visitors can unlock using a QR
code.
Elevator Settings
Requires elevator control module.
Call Elevator
Calls the elevator to the current floor when the door station is accessed.
Elevator Server Setting
Sets the IP address of the elevator controller server.
Elevator Controller Status
Checks the status of the elevator controller.
Elevator Controller Number Setting
Matches the elevator controller number.
Elevator Floor Number Setting
Sets the floor number the elevator will arrive at. The first floor is 0, B1
is 1, B2 is 2, and so on, with a maximum value of 15.
Language Settings
Set the system language (default is Chinese).
Advertisement Playback (Optional)
Enable or disable advertisement playback.
Date and Time Settings
Enable automatic date and time settings, or set manually if needed.
If the time setting is unreasonable, the system will prompt a failure. The
door phone will automatically sync time with the property center when turned
on or running. The format is YYYY-MM-DD HH, e.g., 2019-01-01 08:00.
Theme Switching
Select the application theme based on user preference.
Operation Settings
Enable or disable call hang-up after unlocking.
System Information
View system information such as device number, IP address, gateway, subnet
mask, program version, release date, network configuration version, and system
version.
Factory Reset
Select “Factory Reset,” select“ confirm” or“#” to reset the system,
“cancel” or“*”to return.
Test Mode
Click “Test Mode” to restart the system and enter test mode. This mode
includes tests for continuous flow, loop, camera, microphone, speaker, LCD
display, touchscreen, system card reading, wired network, SD card, human
presence, tamper detection, pressure test images, pressure test videos, door
sensor, unlocking, and door open button.
Click the “Hardware” button in the top right corner to test the camera,
microphone, speaker, LCD display, touchscreen, GPIO port, serial port, system
card reading, system buttons, wired network, and SD card. Click “Back” to exit
test mode.
One-Key Restart
Click “One-Key Restart” to reboot the device.
Installation method
The Notice
- Do not expose the device to wind and rain. If unavoidable, please install a rain cover.
- Do not aim the camera at direct sunlight or strong light.
- Ensure the camera has even lighting as much as possible.
- Do not install the device near strong magnetic fields.
- Do not install the device in locations where the background noise exceeds 70dB.
- Only qualified professionals should perform repairs. For technical issues, please call our national service hotline at 400-6116-328.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>