Trudian TD-12MWT Access Control Terminal User Manual

June 1, 2024
Trudian

Trudian-logo

Trudian TD-12MWT Access Control Terminal

Specifications

  • Operating voltage: 12V DC
  • Operating current: 200mA~380mA
  • Camera: 640 x 480 camera
  • Door opening method: QR code, swipe card, Bluetooth, mobile App remote, cloud platform remote
  • Card capacity: Unlimited (read/write sectors)
  • Card type: IC card
  • Card reading distance: 0~4cm
  • QR code reading distance: 4~18cm
  • Communication interface: 10/100Mbps adaptive Ethernet interface, 485 bus interface
  • External interface: Door lock control 1, door opening button 1, door magnetic detection *1
  • Operating humidity: 10%~93%
  • Operating temperature: -20~+70 degrees Celsius
  • Installation method: Wall mounting type
  • Device appearance dimension: 110*25mm
  • Material: ABS case + acrylic lens

Product Usage Instructions

Function Description

Select the boot mode
Follow the instructions provided in the user manual to select the desired boot mode for the device.

Unlocking method
After the access control device starts normally, it can be unlocked using the following methods:

  • Card Swipe Unlock: Insert and swipe a card to unlock.
  • Bluetooth Unlocking: Open the mobile app, tap the Unlock button. Upon successful unlocking, the buzzer will emit a single beep sound, and the indicator light will flash once with a green light. If the unlocking fails, the buzzer will emit three beep sounds, and the indicator light will flash three times with a red light.

Elevator Control
Additional information on elevator control can be found in the user manual provided.

Interface Description
Detailed information about different interface functions is provided in the user manual.

Wiring Diagram
Refer to the wiring diagram section in the user manual for guidance on wiring connections.

Notices

  1. Do not expose the device to rain or inclement weather. Consider using a rain cover if unavoidable.
  2. Avoid direct exposure of the camera to sunlight or strong light. Maintain uniform lighting for optimal camera performance.
  3. Avoid installation near strong magnetic fields.
  4. Avoid installation in areas with background noise exceeding 70dB.
  5. Non-professionals are not allowed to dismantle the device for repairs.

Frequently Asked Questions (FAQ)

  • Q: What should I do if I encounter issues with unlocking using Bluetooth?
    A: If you face difficulties with Bluetooth unlocking, ensure that your mobile app is properly connected to the device and try again. If problems persist, refer to the troubleshooting section in the user manual or contact customer support for assistance.

  • Q: Can I increase the card reading distance of the device?
    A: The card reading distance is fixed at 0~4cm for this device and cannot be increased. Ensure proper positioning of the card for successful reading.

Smart QR Code Cloud Access Control Device User Manual

Function Description

Select the boot mode
The dip switch SW1 on smart QR Code access control device circuit board can select the operating mode. When neither dip switch 1 nor dip switch 2 is toggled, the access control device operates in normal online cloud access control mode; when dip switch 1 is toggled to ON and dip switch 2 is not toggled, the access control device operates in online mode with 485 access control; when dip switch 1 is not toggled and dip switch 2 is toggled to ON, the access control device operates in normal offline mode; when both dip switch 1 and dip switch 2 are toggled to ON, the access control device operates in offline mode with 485 access control.

Unlocking method
After the access control device starts normally, it can be unlocked in the following ways:

  • Card Swipe Unlock:
    Place an authorized legitimate card near the card swipe area at the bottom of the access control device. The optimal distance for card readability is 0 to 6cm. Upon successful unlocking with a legitimate card, the buzzer will emit a “beep” sound, and the indicator light will flash once with a green light. If an unauthorized card is used for unlocking, the buzzer will emit three “beep” sounds, and the indicator light will flash thrice with a red light, indicating unlock failure.

  • Remote Unlocking:
    When the access control device is connected online, open the mobile app(Trudian cloud app), tap the “Unlock” button, or have the administrator on the cloud platform click “Unlock” to remotely unlock. Upon successful unlocking, the buzzer will emit a single “beep” sound, and the indicator light will flash once with a green light. If the unlocking fails, the buzzer will emit three “beep” sounds, and the indicator light will flash three times with a red light.

  • Bluetooth Unlocking:
    Open the mobile app, tap the “Unlock” button. Upon successful unlocking, the buzzer will emit a single “beep” sound, and the indicator light will flash once with a green light. If the unlocking fails, the buzzer will emit three “beep” sounds, and the indicator light will flash three times with a red light.

  • QR Code Unlocking:
    Open the mobile app(Trudian cloud APP), click on “Authorization Code Unlock” on the main interface to generate a QR code. Click on “Authorize to Visitor” below the QR code, set the visitor’s identity, authorization code validity, and rules. Click “Send to Visitor” to share it with the visitor via WeChat, Tencent QQ, or SMS. Present the QR code generated in the mobile app in front of the camera, ensuring it is within the recognizable range. This will complete the QR code unlocking process. After successful unlocking, the buzzer will emit a single “beep” sound, and the indicator light will flash once with a green light. In case of unlocking failure, the buzzer will emit three “beep” sounds and the indicator light will flash three times with a red light.

Elevator Control
The communication between the access control device and the elevator is achieved using the 485 bus. The 485A/B bus in the J3 interface of the device is correspondingly connected to the 485A/B bus on the elevator controller, allowing the synchronization of information between the two by swiping the elevator control management card. When the access control device is operating in the mode with 485 access control, users can achieve elevator interlock functionality by swiping an authorized legitimate IC card or scanning an authorized QR code after authorization in the card swipe area of the access control device.

Interface Description

Trudian-TD-12MWT-Access-Control-Terminal-fig- \(1\)

Loca;on Func;on Descrip;on
J6 LAN network cable port
J1 Power input interface
J3 485 Bus A/B port
J2 Door lock control and door opening buOon interface
J5 Linkage interface for door sensor detec;on and fire control
SW1 00: Normal TCP/IP network mode

10: Network mode with 485 access control 01: Normal offline mode
11: Offline mode with 485 access control
Interface Name| Function Description
---|---
12V| DC12V power input
GND| Ground connection
NC| Relay Normally Closed
COM| Relay Common terminal
NO| Relay Normally Open
EXIT| Door opening key signal detection
DSW| Door magnetic signal detection
485A/B| 485 bus A/B end
ALARM| Fire Linkage Interface

Wiring Diagram

Trudian-TD-12MWT-Access-Control-Terminal-fig- \(2\)

Notices

  1. Do not expose to rain or inclement weather; if unavoidable, consider installing a rain cover.
  2. Avoid direct exposure of the camera to sunlight or strong light; try to maintain uniform lighting for the camera.
  3. Do not install near strong magnetic fields.
  4. Do not install in areas with background noise exceeding 70dB.
  5. Non-professionals are not allowed to dismantle the device for repairs.

Specifications

Operating voltage DC12V±10%
Operating current 200mA~380mA
Camera 640 x 480     camera
Door opening method Qr code, swipe card, Bluetooth, mobile App remote, cloud

plaXorm remote
Card capacity| Unlimited (read/write sectors)
Card type| IC card
Card reading distance| 0~4cm
QR code reading distance| 4~18cm
Communication interface| 10/100Mbps adaptive Ethernet interface, 485 bus interface
External interface| Door lock control 1, door opening button 1, door magnetic detection 1
Operating humidity| 10%~93%
Operating temperature| -20℃~+70℃
Installation| wall mounting type
method|
---|---
Device appearance dimension| φ110
25mm
Material| ABS case + acrylic lens

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Trudian User Manuals

Related Manuals