Trudian TD-8701 Multi Door Access Controller User Guide
- June 12, 2024
- Trudian
Table of Contents
Trudian TD-8701 Multi Door Access Controller
Product Information
- Product Name: Multi-door Access Controller
- Applicable Models: TD-8701, TD-8702, TD-8704
- Version: 1.0
- Date: May 2023
Product Overview
- Input: DC12V/500MA
- Working mode: Networked, offline multi-mode selectable
- Issuing mode: Card management platform
- Card capacity: 40000
- Password capacity: 20000
- Working temperature: -20°C to 70°C
- Relative humidity: 20% to 93%
- Size: 16210538.5MM
Controller Interface Description
Interface Name | Function Description | Remarks |
---|---|---|
+12V | DV12V power input | |
GND | Ground |
System Wiring References
- Refer to the user manual for system wiring references.
Multi-door Control Function Description
- Offline working: Switch Setting 01
- TCP/IP LAN networking: Switch Setting 00
- The device can be unlocked through the door button, remote APP, cloud server platform remote, and management center platform remote. Various methods including card swipe, card and password combination can be used to lock and unlock the device.
Multi-door Control Configuration
- In the management center, add the controller and configure its permissions. Bind the controller to the corresponding regional access control.
- Add users and configure their permissions in the management center for the corresponding area.
Remote Control Controller
- Using the Trudian APP, you can remotely open doors and view access records. After logging in with the user added in the management center, you can control the controllers remotely through the APP.
Product Overview
Parameter:
Input
| ****
DC12V/500MA
---|---
Working mode
| ****
networked, offline multi-mode selectable Card
issuing mode
| ****
management platform card issuing
Card capacity
| ****
40000
Password capacity
| ****
20000
Working temperature
| ****
-20℃~70℃
Relative humidity
| ****
20% ~ 93%
size
| ****
16210538.5MM
Controller interface description
Interface description:
Interface Name
| Function Description| ****
Remarks
| ****
Interface Name
| Function Description| ****
Remarks
---|---|---|---|---|---
+12V| DV12V power input| | ****
GND
| ****
ground
|
12V
| Wegen Readhead Power Supply| | ****
ALARM
| Firefighting linkage signal|
GND| Wegen Reading Headland| ****
Total of 4 groups of signals for 4 readheads
| NO| Relays normally open| ****
Total of 4
signals for 4 locks
D1| Wegen Readhead D1| COM| Relay Common
D0
| Wegen Readhead D0| ****
NC
| Relay normally closed terminal
LED
| Indicator synchronization signal|
EXITx| Exit button signal| ****
Total of 4
signals for 4 gates
| DSWx| Door magnetic detection signal| ****
Total of 4
signals for 4 gates
GND
| Go out button ground| ****
GND
| Magnetic door detection ground
SW1 dip switch: (dip code does not dial means 0, dip code dial to ON means 1)
00: TCP/IP LAN networking 01: Offline
System wiring references
Multi-door Controll Function Description
Operating mode selection
Startup status
TCP/IP LAN networking : When the power is on, the blue LED flashes,
indicating that it is looking for the network. When normally connected to the
network, the buzzer “tick ~ tick” two short beeps, the LED red light is always
on, indicating that the cloud access control has started normally; when 20
seconds later is not normally connected to the network, the buzzer “tick tick
tick” three beeps, the LED red light is always on, indicating Connection
network failure, the controller forced to start. After the controller is
normally connected to the network, the LED green light will flash once every
20 seconds, indicating that there is data and the cloud platform interactive
communication.
Offline working: When the power is started, the buzzer “beep” a short
beep, the LED red light is always on, indicating that the cloud access control
has started normally.
Unlock status
When the lock is opened legally, the buzzer of the controller and the reading head will be “beep” at the same time, accompanied by a green LED flashing once, and the corresponding relay will be jumped, which means that the lock is opened successfully; when the lock is opened illegally, the buzzer of the controller and the reading head will be “beep beep beep” three times at the same time, accompanied by a red LED flashing three times, which means that the lock is opened and failed.
Unlock method
The device can be unlocked through the door button, remote APP, cloud server platform remote, and management center platform remote; after accessing the reading head, it can also be unlocked through various ways such as swipe card and password (optional).
Multi-door Controll Configuration
Management Center Add Controller
Connect the controller to the PC with a network cable, open the controller management software, and click Add Controller by Search. At this time, the management software can automatically search for the multi-door controllers connected to the LAN and assign them to the corresponding IP. Then configure the controller to the corresponding area. Click to confirm that the controller can be bound to the corresponding regional access control.
Add user and configure his permissions
In the management center, add users to configure the rights of the
corresponding area controllers for them. After the configuration is completed,
users can open the door in the room where these controllers are installed by
swipe card, APP, password, etc. More detailed controller management and
Add User:
Configuration Permissions:
Remote control controller
Remotely open doors and view access records
After you open Trudian APP and log in the user you have added in the
management center, the APP home page shows all the controllers that the
current user can control. You can open the door remotely in APP, and you can
also view all the door opening information recorded by the controller in APP.
View access records with APP
- www.trudian.com/en/
- HQ Add: Farbell Technology Park,Yixian Road, Nanlang, Cuiheng New District, Zhongshan City, Guangdong Province, China. Zip Code:528451
- Phone: +86 0760 – 23689666
- E-mail: sales@trudian.com
- If the problem is not solved properly,please send the mail to:support@trudian.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>