scheppach ASP20-ES Wet and Dry Vacuum Cleaner Instruction Manual
- June 5, 2024
- Scheppach
Table of Contents
scheppach ASP20-ES Wet and Dry Vacuum Cleaner
Introduction
Manufacturer:
D-89335 Ichenhausen
Dear Customer,
We hope your new tool brings you much enjoyment and success.
Note:
According to the applicable product liability laws, the manufacturer of the
device does not assume liability for damages to the product or damages caused
by the product that occurs due to:
- Improper handling,
- Non-compliance of the operating instructions,
- Repairs by third parties, not by authorized service technicians,
- Installation and replacement of non-original spare parts,
- Application other than specified,
- A breakdown of the electrical system that occurs due to the non-compliance of the electric regu-lations and VDE regulations 0100, DIN 57113 /VDE0113.
We recommend:
Read through the complete text in the operating instructions before installing
and commissioning the device. The operating instructions are intended to help
the user to become familiar with the machine and take advantage of its
application possibilities in accordance with the recommendations. The
operating instructions contain important information on how to operate the
machine safely, professionally and economically, how to avoid danger, costly
repairs, re-duce downtimes and how to increase reliability and service life of
the machine.
In addition to the safety regulations in the operating instructions, you have to meet the applicable regula-tions that apply for the operation of the machine in your country. Keep the operating instructions pack-age with the machine at all times and store it in a plastic cover to protect it from dirt and moisture. Read the instruction manual each time before operating the machine and carefully follow its information. The machine can only be operated by persons who were instructed concerning the operation of the machine and who are informed about the associated dangers. The minimum age requirement must be complied with. In addition to the safety requirements in these operating instructions and your country’s applicable regulations, you should observe the generally rec-ognized technical rules concerning the operation of woodworking machines.
Device description
- Handle
- Machine head
- Connection cable
- Locking hooks
- Castor mounts (4x)
- Castors (4x)
- Castor mounting base
- Stainless steel container
- Suction connection
- On/off switch
- Top cable holder
- Connection for blower function
- Filter basket with safety float valve
- 2 m suction hose
- Foam filter
- Paper filter bag
- Folded filter (optional)
- Floor nozzle
- Joint nozzle
- Plastic extension tube (3x)
- Screw (2x)
- Bottom cable holder
Scope of delivery
- Open the packaging and remove the device care-fully.
- Remove the packaging material as well as the packaging and transport bracing (if available).
- Check that the delivery is complete.
- Check the device and accessory parts for trans-port damage.
- If possible, store the packaging until the warranty period has expired.
ATTENTION!
The device and packaging materials are not toys! Children must not be allowed
to play with plastic bags, film and small parts! There is a risk of swal-
lowing and suffocation!
- 20L wet/dry vacuum cleaner (1x)
- 2m suction hose (1x)
- Foam filter (1x)
- Paper filter bag (1x)
- Castor mount (4x)
- Castors (4x)
- Handle (1x)
- Screw (6x)
- Floor nozzle (1x)
- Joint nozzle (1x)
- Plastic extension tube (3x)
- Cable holder (1x)
- Operating manual (1x)
Proper use
The wet and dry vacuum cleaner is designed for wet and dry vacuuming using the
appropriate filter. The appliance is not suitable for the vacuuming of
combustible, explosive or harmful substances.
The equipment is to be used only for its prescribed purpose. Any other use is
deemed to be a case of misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind caused as a result of
this.
Please note that our equipment has not been de-signed for use in commercial,
trade or industrial applications. Our warranty will be voided if the equipment
is used in commercial, trade or industrial businesses or for equivalent
purposes.
Safety instructions
DANGER!
- The appliance may only be connected to alternating current. The voltage must correspond with the type plate on the appliance.
- Never touch the mains plug and the socket with wet hands.
- Do not pull the plug from the socket by pulling on the connecting cable.
- Check the power cord with mains plug for damage before every use. To avoid risks, arrange immediately the exchange by an authorized customer service or a skilled electrician, if the power cord is damaged.
- To avoid accidents due to electrical faults we recommend the use of sockets with a line-side cur-rent-limiting circuit breaker (max. 30 mA nominal tripping current).
- Turn off the appliance and remove the mains plug prior to any care and maintenance work.
- Repair works may only be performed by the authorised customer service.
- Keep packaging film away from children – risk of suffocation!
- Switch the appliance off after every use and prior to every cleaning/maintenance procedure.
- Risk of fire. Do not vacuum up any burning or glow-ing objects.
- The appliance may not be used in areas where a risk of explosion is present.
- Immediately switch the appliance off or pull the power plug if foam forms or liquids escape!
- Do not use abrasives, glass or universal cleaners!Never immerse the appliance in water.
- Explosive or combustible gases, liquids and dust particles (reactive dust particles)
- Reactive metal dust particles (such as aluminium, magnesium, zinc) in combination with highly alka-line or acidic detergents
- Undiluted, strong acids and alkalies
- Organic solvents (such as petrol, paint thinners, acetone, heating oil).
In addition, these substances may cause the appli-ance materials to corrode.
WARNING!
This electric tool generates an electromagnetic field during operation. This
field can impair active or pas-sive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries, we recommend that
persons with medical implants consult with their physician and the
manufacturer of the medical implant prior to operating the elec-tric tool.
Technical Data
Mains voltage | 220-240V~ 50/60Hz |
---|---|
Power | 1200W |
Water tank capacity | 20L |
Suction performance | 18 Kpa |
Protection category | IPX4 |
Protection class | II |
Installation
IMPORTANT!
Prior to use, ensure that the device has been correctly and fully assembled.
Unpacking (Fig. 1+2+3)
Release the locking hooks (4) and remove the machine head (2). The accessories are located inside the stainless steel container (8). Only the plastic extension tubes (3x) (8) are located outside the stainless steel container, in the packaging. Remove all of the accessories from the stainless steel container (8).
Installing the castor mounts (fig. 4+5)
- Turn the stainless steel container (9) upside-down (the machine head (2) must be removed).
- Push the castor mounts (5) into the cut-outs provi- ded on the wheel mounting base (7). (4x)
- Fasten the castor mounts (5) with a screwdriver (not included in the delivery) and one screw each (20). (4x)
Installing the castors (fig. 6)
- Press the four castors (6) into the holes in the castor mounts (5).
Installing the machine head (2) and the handle (1)
(Fig. 7)
- Place the machine head (2) on the stainless steel container (8). Secure the machine head (2) with the locking hooks (4). When installing the machine head (2), ensure that the locking hooks (4) latch into place
- Place the handle (1) on the machine head (2) and fasten it with two screws (21) with a screwdriver (not included in the delivery).
Installing the foam filter (15) (fig. 3+8)
Never use the device without filter! Always ensure that the filters are correctly fitted!
Installing the foam filter (15): For wet vacuuming, slide the foam filter (15) provided over the filter basket with safety float valve (13).
Installing the folded filter (17) (fig. 3+9)
For dry vacuuming, slide the folded filter (17) provided over the filter basket with safety float valve (13). The folded filter (17) is only suitable for dry vacuuming!
Installing the paper filter bag (16) (fig. 3+10)
It is recommended to use an additional paper filter bag (16) when vacuuming fine, dry dirt. Slide the paper filter bag (16) over the suction opening in the stainless steel container (9). The paper filter bag (16) is only suitable for dry vacuuming. The paper filter bag (16) makes it easier to dispose of the dust collected.
Installing the suction hose (fig. 11 + 12)
Connect the suction hose (14) to the corresponding port, depending on the desired use, on the wet and dry vacuum.
Vacuuming:
Connect the suction hose (14) to the suction hose port (9). To do so, slide the end of the suction hose
(14) with the two nipples into the suction hose port (9) (A). Insert the two nipples into the recesses. Once the suction hose is fully inserted, turn it clockwise (B).
Blowing:
Connect the suction hose (14) to the suction hose port (12). Slide the end of the suction hose (14) with the two nipples into the blowing function connection port (12). Insert the two nipples into the recesses. It is not necessary to turn it here
Installing the plastic extension tubes, suction hose and floor nozzle (fig. 13)
Assemble the plastic extension tubes (20) by pushing them together. Connect the assembled plastic exten- sion tubes with the bent end of the suction hose (14). Fit the floor nozzle (18) or joint nozzle (19) to the other end of the assembled plastic extension tubes.
Installing the bottom cable holder (fig. 2+14)
Clip the bottom cable holder (20) onto the wheel mounting base at the rear of the device. The top ca- ble holder (7) is on the connection port for the blower function (12).
Operation
WARNING!
Switch the device off if liquid or foam emerges with the exhaust air during wet vacuuming.
Switching on/off (fig. 15)
The on/off switch (11) has two settings
- Switch setting 0: Off
- Switch setting I: On
Press the on/off switch (11) to switch on. Switch set- ting I: On
Press the on/off switch (11) again to switch the device off. Switch setting 0: Off
Dry vacuuming (fig. 3+9)
Use the folded filter (18) for dry vacuuming. The pa- per filter bag (17) can be used in addition. This en- sures that the folded filter (18) remains free of dust for longer and maintains the vacuum power for longer. In addition, the disposal of the dust is also easier.
Always ensure that the filters are correctly fitted.
Wet vacuuming (fig. 3+8)
Use the foam filter (16) for wet vacuuming. Ensure that the foam filter (16) is correctly fitted.
If the stainless steel container (9) is full, the safety float valve (14) closes the suction port and suction operation is interrupted.
IMPORTANT!
The device is not suitable for vacuuming flammable liquids. For wet vacuuming, use the only the foam filter (16) provided. To remove the liquid vacuumed up from the stainless steel container, take off the machine head by releasing the locking hooks (4) from the stainless steel container (9). Pour out the liquid residue
Maintenance and cleaning
WARNING!
Prior to any adjustment, maintenance or service work disconnect the mains
power plug!
Cleaning
It is recommended to clean the device after each use. Do not spray the device
with water or clean it under running water. This can result in electric shocks
and can damage the device.
Residual liquid remains in the stainless steel contain-er (9). To remove
residual liquid, take off the machine head (2) by releasing the locking hooks
(4) from the stainless steel container (7). Pour out the liquid resi-due.
Clean the container with a damp cloth.
- Replace paper filter bag when full
- Always keep the device clean. Do not use cleaning agents or solvents.
- Keep the ventilation slots clean and free of dirt and dust.
- Clean the device only with a soft brush or a damp cloth.
- Clean the foam filter (13) with a little soap and run-ning water and then leave it to air dry.
Maintenance
The device is maintenance-free.
Service information
Please note that the following parts of this product are subject to normal or
natural wear and that the fol-lowing parts are therefore also required for use
as consumables.
Wear parts*:
-
Not necessarily included in the scope of delivery!
- Foam filter
- Paper filter bag
- Folded filter for dry vacuuming
Storage
Store the device and its accessories in a dark, dry and frost-proof place that
is inaccessible to children. The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging. Cover the electrical tool
in order to protect it from dust and moisture.
Store the operating manual with the electrical tool.
-
Wind the mains cable around the top cable holder
(12) at the connection port for the blower function
(13) and the bottom cable holder (23). (Fig. 18) -
There are four recesses on the top side of the ma-chine head (2) for storing the floor nozzle (19) and the joint nozzle (20). There are also recesses on the wheel mounting base (5) for attaching the met-al extension tube. (Fig. 19)
-
The remaining accessories can be stored in the stainless steel container (9).
Electrical connection
The electrical motor installed is connected and ready for operation. The
connection complies with the ap-plicable VDE and DIN provisions.
The customer‘s mains connection as well as the extension cable used must also
comply with these regulations.
Important information
In the event of an overloading the motor will switch itself off. After a cool-
down period (time varies) the motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-ten damaged.
This may have the following causes:
- Passage points, where connection cables are passed through windows or doors.
- Kinks where the connection cable has been im-properly fastened or routed.
- Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used and are life- threatening due to the insula-tion damage.
Check the electrical connection cables for damage regularly. Make sure that the connection cable does not hang on the power network during the inspection. Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use con-nection cables with the marking „H05VV-F“.
The printing of the type designation on the connection cable is mandatory.
AC motor
- The mains voltage must be 230 V~
- Extension cables up to 25 m long must have a cross-section of 1.5 mm2.
Connections and repairs of electrical equipment may only be carried out by an
electrician.
Please provide the following information in the event of any enquiries:
Disposal and recycling
The equipment is supplied in packaging to prevent it from being damaged in
transit. The raw materials in this packaging can be reused or recycled. The
equipment and its accessories are made of various types of material, such as
metal and plastic. Defective components must be disposed of as special waste.
Ask your dealer or your local council.
troubleshooting
Fault
| ****
Possible cause
| ****
Remedy
---|---|---
Motor does not run
| ****
Check whether the plug is plugged in.
| ****
Plug the mains plug back in to the socket.
Check whether there is power to the socket.
| ****
Call an electrician.
Check whether the vacuum cleaner on/off switch is switched on.
| ****
Switch the on/off switch on.
Reduced vacuuming power
| ****
Is the brush blocked?
| ****
Switch the vacuum cleaner off to remove the blockages.
Is the dust bag full of dust?
| ****
Remove and empty the dust bag.
Is the filter full of dust?
| ****
Remove and empty the filter.
scheppach Fabrikation von Holzbearbeitungsmaschinen GmbH | Günzburger Str. 69 | D-89335 Ichenhause n |www.scheppach.com