Acuity Brands LFRM Series LED Frame with Emergency Battery Instructions
- July 3, 2024
- Acuity Brands
Table of Contents
INSTALLATION INSTRUCTIONS
LED Frame with Emergency Batte
SAVE THESE INSTRUCTIONS
Model Number
MODELS:
LFRM 1X4 ALO3 SWW7 MVOLT IE10WCP
LFRM 2X2 ALO3 SWW7 MVOLT IE10WCP
LFRM 2X4 ALO8 SWW7 MVOLT IE10WCP
Protect yourself. Before installing, read these instructions carefully and
save them for future reference.
Date Installed: ____
TOOLS REQUIRED FOR INSTALLATION
- Safety glasses
- Ladder
- Phillips head screwdriver
- Pencil
- Plier
- Ruler
- Wire Strippers
- Flat blade screwdriver
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the luminaire label
information.
Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
All wiring connections should be capped with UL approved recognized wire
connectors.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn, away from lamp/lens.
Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the
outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire
that are not factory-wired to the luminaire must be checked for compatibility
with the luminaire prior to installation. LED fixtures must be powered
directly off a switched circuit.
Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal
grounding equipment must be worn during all installation or servicing of the
unit.
Do not touch individual electrical components as this can cause ESD,
shorten lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the
unlikely event your unit may require service, stop using the unit immediately
and contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Always ensure that the electrical distribution system is up to NEC (and
any applicable local code) requirements.
**** Verify that power distribution system has proper grounding. Lack of
proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions
under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference
that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts| Indoor Lighting
Aculux
Gotham
Indy
Juno
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen| Controls
DARK TO LIGHT
L&D
ROAM
Sensor Switch
Synergy| Daylighting
SunOptics
---|---|---|---|---|---
Acuity Brands Lighting, Inc. assumes no responsiy for claims arising out of
improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203 ©2010, 2016 Acuity Brands Lighting,
Inc. All rights reserved. 12/01/10
T-BAR CEILING GRID INSTALLATION INSTRUCTIONS
Note: Turn off power at circuit breaker box!
Remove original ceiling tile from the T-Grid ceiling.
Remove 4 Frame pieces from package and connect them together via male and
female side adapter. Connect “A” side from the male to “A” side of the female,
and “B” side from the male to “B” side of the female.
Remove driver box with battery bracket from package and use switch to select
appropriate light color (CCT) and light output (lumen). 40K at high lumen is
factory default setting.
Secure driver box to T-Grid by pushing into grid via clips on the driver box.
Access plate must be facing opening in the ceiling. Secure battery bracket on
top of the T-Grid located adjacent to the ceiling tile the luminaire is to be
installed. Push it down until it is secured. Mount battery test switch as
desired.
For wiring method, see wiring diagram in the battery instruction manual (included).
Optional step for aesthetic improvement only – Attach corner trims (included)
on 4 corners of the fixture.
Install luminaire to the opening in the T-Grid by raising the luminaire above
the grid, then lower it until it rests between the T-Grid and the tile
opening. Cable side of the luminaire must align with cable side of the driver
box.
Connect driver box cable to the luminaire cable by tightening nut connector by hand. Arrow on the male and female parts of the connector between the driver box and luminaire cable should match.
Secure luminaire to driver box by attaching tether cable from luminaire to opening on the driver box using clip.
Optional: Cut out one corner of the ceiling tile using the provided template.
Insert ceiling tile through the opening making sure the cutout portion is
facing corner where the cable is connected between driver box and luminaire.
Turn ON power at circuit breaker and test successful installation.
5-YEAR LIMITED PRODUCT WARRANTY
Vit acuitybrands.com to view the terms ard
conditions of your Acuity Brands Lighting, nc. imited warrany.
ACUITY BRANDS LIGHTING, INC.
ONE LITHONIA WAY, CONYERS, GA 30012
www.AcuityBrands.com
1-800-705-SERV (7378)
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>