BEGA 51 264.4 Indoor Pendant Luminaire Instruction Manual

June 21, 2024
BEGA

BEGA 51 264.4 Indoor Pendant Luminaire

Product Information

Specifications:

  • Lamp Module connected wattage: 27 W
  • Luminaire connected wattage: 31 W
  • Rated temperature: 25 – 60°C
  • Ambient temperature: 25 – 60°C
  • Color temperature: 3000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 4200 lm
  • Luminaire luminous flux: 1122 lm
  • Luminaire luminous efficiency: 36.2 lm/W

Product Usage Instructions

Safety Instructions:
The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning to avoid damage due to improper use or installation.

Overvoltage Protection:
The luminaire’s electronic components are protected against overvoltage per DIN EN 61547. For additional protection against transients, consider using separate overvoltage protection components available on the manufacturer’s website.

Trimming the Cable Pendant:

  1. Ensure the pendant luminaire is securely held in place when adjusting the suspension height.
  2. Lift the luminaire by the cables and attach the strain relievers to the hangers.
  3. Establish an earth conductor connection between the hanger and mounting plate.
  4. Connect the red wire to + and the black wire to – on the marked terminals.

Replacing the LED Module:

  1. Identify the LED module designation on the label inside the luminaire.
  2. Disconnect the system, open the luminaire, and follow the installation instructions for replacing the LED module.
  3. Qualified individuals can replace the module using standard tools.
  4. If the luminaire cover is defective, it must be replaced before closing the luminaire.

FAQ:

  • Q: Can I replace the LED module myself?
    A: Qualified persons can replace the LED module using standard tools. Ensure to disconnect the system and follow the installation instructions provided.

  • Q: What should I do if the luminaire cover is damaged?
    A: If the luminaire cover is defective, it must be replaced before closing the luminaire to maintain proper functionality.

Application

  • Pendant luminaire · Indoor luminaire with metal housing and diffuser for glare-free, shielded light directed upward and downward.
  • A luminaire with uniform light distribution for linear indoor illumination.

Product Description

  • Luminaire housing and canopy made of metal, finish Colour velvet brass
  • Silicone light diffuser 3 elongated fixing holes
  • Width 4.5 mm · 345 mm spacing
  • Mounting plate with several openings for cable entry and through-wiring for mains cable
  • Synthetic 2-piece line connector (clamp part with screw cap) for braided coaxial cables
  • With internal pressure spring and contact wire
  • Cable pendant · Sheath cable white 2 x 0,75@
  • The overall length of the luminaire is approx. 2000 mm
  • Connecting terminals 2.5@
  • Earth conductor connection
  • Complies with flicker requirements under IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit inside the canopy
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic isolation exists between the power cable and control line BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • – Conformity mark
  • This product contains light sources of energy efficiency class(es) D
  • Weight: 2.9 kg

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

  • The electronic components installed in the luminaire are protected against overvoltage per DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 27 W
  • Luminaire connected wattage 31 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 60 °C

51 264.4 K3

  • Module designation LED-1319/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 4200 lm
  • Luminaire luminous flux 1122 lm
  • Luminaire luminous efficiency 36,2 lm/W

Before installation, please note:

  • To ensure correct mounting and installation of the luminaire, the mounting plate must be installed on an even ceiling surface.
  • When mounting the luminaires, it must be ensured that the ceiling surface has sufficient load-bearing capacity.
  • The fixing material provided must be checked for compatibility with the specific mounting surface. If necessary, replace it with suitable fixing material.
  • Please check the secure mounting of the luminaires after installation.
  • IMPORTANT: The pendant luminaire must only be mounted in a horizontal burning position.

Installation

LEDs are high-quality electronic components!

  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove the canopy and luminaire from the packaging and position them on a soft surface.
  • Detach the canopy downwards from the mounting plate against the magnetic resistance.
  • Disconnect the earth conductor connection between the canopy and the mounting plate (plug contact).
  • Unclip the snap hooks on both sides of the mounting plate.
  • Disconnect the wires (red/black) of the luminaire cables from the power supply unit terminals near the magnets on both sides.
  • Unclip the strain relievers from the hanger eyelets on both sides.
  • Lead the power connecting cable through the mounting plate.
  • Attach the mounting plate to the ceiling using the fastening material supplied or other suitable fixing material.
  • Make sure to use the gaskets supplied.
  • Shorten mains supply cable as required and dismantle max. 80 mm.
  • Make the electrical connection to the terminals.
  • Please ensure the correct wire assignment for the connecting cable.
  • Connect the earth conductor to the green-yellow wire (1). Connect the live conductor to the brown wire ( ) and the neutral conductor to the blue wire (N).
  • Use the terminals marked DA, DA for digital control.
  • If these terminals are not used, the luminaire will operate at full light output.
  • Lift the pendant luminaire by the luminaire cables and clip both strain relievers into the eyelets on the luminaire hanger.BEGA-51-264.4-Indoor-Pendant-Luminaire-Fig-3

Trimming the cable pendant

  • IMPORTANT: Ensure the pendant luminaire is held firmly in place when setting the desired suspension height!
  • To fine-tune the suspension height, loosen the knurled nut, adjust the cable length, and tighten the knurled nut again.
  • Once the correct suspension height is adjusted, unhook the luminaire hanger from the mounting plate and carefully place the pendant luminaire onto a safe surface.
  • Remove the strain reliever from the luminaire hanger.
  • Shorten the excess luminaire cable so that a projection of 120-130 mm remains above the strain reliever.
  • Strip 60 mm to max. 80 mm of the insulation from the luminaire cable at the top end.BEGA-51-264.4-Indoor-Pendant-Luminaire-Fig-4

Installing the coaxial cable connector

  • Unscrew the line connector.
  • Guide the stripped cable end (A) into the lower part of the connector (clamp part) (B) until it stops.
  • Hold the luminaire cable below the lower part of the connector.
  • Carefully push together the coaxial mesh of the stripped section with two fingers of your other hand bit by bit directly above the connector thread, until the black wire is laid bare.
  • Make sure that the coaxial mesh is inserted into the recess on the lower part of the connector – see diagram (C).
  • Guide the black wire through the opening in the middle of the screw cap.
  • Make sure that the red wire is correctly positioned in the cap with the internal pressure spring. Screw the closing cap (top part of the connector) in a clockwise direction onto the clamp part (lower part of the connector) until it stops (D).
  • Strip back 7–8 mm of the black wire (E).
  • Lift the pendant luminaire by the luminaire cables and clip the strain relievers into the recesses on the luminaire hangers.
  • Establish the earth conductor connection between the luminaire hanger and the mounting plate (plug connector).
  • Make a connection between the red wire to “+” and a connection between the black wire to “-” to the marked terminals.
  • Guide the canopy evenly upward along the luminaire cables and hook the safety steel wire into the mounting plate on both sides using the snap hooks.
  • NOTE: Using two knurled nuts over the strain relievers of the luminaire cables, an additional fine adjustment can be carried out on the horizontal orientation of the pendant luminaire.
  • By turning the knurled nuts to the left/right, a maximum height adjustment of 5 mm (± 2.5 mm) is possible in either direction.
  • Establish the earth conductor connection between the canopy and the mounting plate (plug contact).
  • IMPORTANT: Make sure that none of the luminaire wires are pinched in when installing the canopy.
  • Guide the canopy to the ceiling until the magnets on the mounting plate secure it in its final position.

Dimension

BEGA-51-264.4-Indoor-Pendant-Luminaire-Fig-1

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • The defective luminaire cover must be replaced.
  • Close the luminaire.

Spares Parts

  • LED power supply unit DEV-0388/700i
  • LED module 3000 K LED-1319/930
  • Strain relief 75 004 118
  • Cable connector 75 004 119

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals