Unbranded Q5RD Single Package Heat Pump Owner’s Manual

June 15, 2024
UNBRANDED

Unbranded Q5RD Single Package Heat Pump

Product Information

Specifications

  • Product Type: Q5 Series Single Packaged Heat Pump
  • Installation: Slab
  • Listing: ETL and ETLc listed
  • Compressor Type: Scroll Compressor
  • Refrigerant: Earth-friendly non-ozone depleting refrigerant
  • Coil Design: Indoor and outdoor coils designed to optimize heat transfer, minimize size and cost, increase durability and reliability
  • Finish: Polyester urethane coat finish with 950 hour salt spray finish
  • Installation Features: Easy to install and transport, can be installed in tight areas
  • Coil Protection: Rust-proof guard to protect the unit’s coil from damage
  • Drainage: Water drainage system to ensure water drains away from the unit
  • Serviceability: Access panels provided for easy servicing of controls, compressor, evaporator coil, and fan motor
  • Control: Reliable industry-standard control with various time settings
  • Delay System: Five-minute delay system to prevent compressor failure
  • Refrigeration System: Factory installed for easy servicing
  • Protection System: Provides protection from liquid flood back and future compressor failures
  • Fan Motor: Heavy-duty PSC motor for long-lasting reliability and quiet operation
  • Fuse: Includes 3 Amp fuse to protect low voltage circuit
  • Drainage Design: Optimized drainage capabilities
  • Installation Cost: Design to reduce installation costs

Product Usage Instructions

Installation
To install the Q5 Series single packaged heat pump, follow these steps:

  1. Choose a suitable location on a slab for installation.
  2. Ensure the unit is ETL and ETLc listed.
  3. Make sure the installation area is well-ventilated and has proper clearance for airflow.
  4. Connect the necessary electrical power supply according to the specifications provided.
  5. Securely mount the unit on the slab.
  6. Connect the necessary ductwork for proper airflow.
  7. Ensure all connections are tight and secure.

Service and Maintenance
To service and maintain the Q5 Series single packaged heat pump, follow these steps:

  1. Make sure the unit is powered off and disconnected from the electrical supply.
  2. Remove the access panels provided on the side of the unit to access controls, compressor, evaporator coil, and fan motor.
  3. Clean the evaporator coil regularly to ensure optimal performance.
  4. Inspect and clean the fan motor for any debris or dust buildup.
  5. Check for any signs of damage or corrosion on the unit’s coil and guard. Replace if necessary.
  6. Ensure proper drainage by checking the water drainage system and clearing any blockages.
  7. Inspect all electrical connections and wiring for any signs of damage or loose connections. Tighten or replace as needed.

FAQ

  • What is the refrigerant used in the Q5 Series single packaged heat pump?
    The Q5 Series uses an earth-friendly non-ozone depleting refrigerant.

  • What is the purpose of the delay system in the Q5 Series?
    The delay system prevents compressor failure by keeping the unit from restarting immediately after shutdown.

  • Can the Q5 Series be installed in tight areas?
    Yes, the Q5 Series has a compact design and can be installed in tight areas thanks to its clearance requirements and installation features.

  • How often should I clean the evaporator coil?
    The evaporator coil should be cleaned regularly to maintain optimal performance. We recommend cleaning it at least once every six months.

WARRANTY

  • This product offers a 10-year All-Parts Warranty.
  • This product offers a 10 year Quality Pledge to replace the entire unit, if the unit’s major component (compressor) fails within the first 10 years of operation, to the original owner.
  • Consumer product registration required for both 10 year All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web site listed on the back of this document for warranty details.

FEATURES AND BENEFITS

  • Quality Compressor: State of the art scroll compressor is standard equipment.
  • R-410A Refrigerant: Earth friendly non-ozone depleting refrigerant.
  • Hi/Low Pressure Switches: Ensure long compressor life.
  • Copper Tube / Aluminum Fin Coils: Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability.
  • Designed using Galvanized Steel: with a polyester urethane coat finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units.
  • Compact Footprint and Profile: make the Q5 Series easy to install and transport.
  • 0″ Clearance: to combustibles on duct side of the unit allows for installations in tight areas.
  • Wire guard coated with Earth Friendly Epoxy and plastic mesh hail guard: A guard that will never rust and protects the units coil from being damaged.
  • Raised Base Pan: allows water to drain away from away from the unit.
  • Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
  • Easy access: to the evaporator coil for cleaning and general maintenance.
  • Removable Top Grille Assembly: Allows ease of service to the fan motor.
  • Time/Temperature Defrost: a reliable, industry standard control offers various time settings to meet any type climate.
  • Five Minute Restart Time Delay: when the units shuts down, a five minute delay keeps the unit from restarting, eliminating the highest cause of compressor failure.
  • Liquid Line Filter Driers: Factory installed at a convenient location for service.
  • Accessible Service Valves: simplify servicing of the refrigeration system.
  • Suction Accumulator: provides protection from liquid flood back and future compressor failures.
  • Permanently Lubricated Condenser Motor: A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow.
  • Low voltage Transformer: Includes 3 Amp fuse to protect low voltage circuit.
  • Drain Trap Included: design optimizes drainage capabilities.
  • Duct Collars: reduce installation costs.
  • Outdoor thermostat: is standard equipment.
  • Optional Electric Heat: Field installed 5 – 20 KW.

MODEL IDENTIFICATION CODE

DIMENSION

PHYSICAL SPECIFICATIONS

Q5RD Models

  • Amperage and wire size based on refrigeration system only with 60° C wire, 50 ft. length. See Electrical Data tables for supplemental electric heaters. Refer to National Electric Code for additional derating factors for field installed conductors.
  • Use time delay fuse or “HACR” type circuit breaker.

SYSTEM HEATING AND COOLING CAPACITIES

Q5RD SERIES SMALL PACK

NOTES:
Temperature rises shaded gray are for reference only. These conditions are not recommended. Heat rise valves calculated with 10KW Heater Kit.

  • Denotes factory set cooling speed
  • Denotes factory set electric heating speed
  • Denotes Factory cooling and electric heating speed

ACCESSORIES

Q5RD SERIES – 208/230V – SINGLE PHASE MODELS

Q5RD SERIES – 208/230V – SINGLE PHASE MODELS

MODEL IDENTIFICATION CODE

Q5RD Heater Kit Application Matrix

HEAT PUMP COOLING EXPANDED RATINGS

Q5RD-024K

Q5RD-030K

Q5RD-036KA

Q5RD-042K

Q5RD-048KA

Q5RD-060K

HEAT PUMP HEATING EXPANDED RATINGS

Q5RD-024K

Q5RD-030K

Q5RD-036KA

Q5RD-042K

Q5RD-048KA

Q5RD-060K

GENERAL TERMS OF LIMITED WARRANTY

  • NORDYNE will furnish a replacement for any part of this product which fails in normal use and service within the first ten years of installation, in accordance with the terms of the warranty.
  • For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.

ABOUT COMPANY

  • 8000 Phoenix Parkway
  • O’Fallon, MO 63368-3827
  • Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (09/2010)
  • 205D-0910 (Replaces 205D-0809)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

UNBRANDED User Manuals