IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and AS/NZS Standards, which require installation in accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance guarantee unless expressly confirmed in writing by SAL at the time of order.
SALRAY 1500 & SALRAY 3000 SOLAR LED FLOODLIGHT electrical and installation specification effective 8/1/2024.
General product application requirements (if applicable) :
1. CCT or POWER selections (where supplied) – IMPORTANT, where CCT colour
temperature or POWER selection switching is provided, it is important to
switch OFF the power before the selection is made, otherwise equipment damage
may occur.
2. Recycling – SAL encourages recycling, please consider the environment when
disposing of packaging, batteries & components.
3. Switching or test intervals – For optimum product performance, good design
practice does not encourage 24/7 operation of lighting products without the
provision of a routine switching or regulatory test cycle. As a guide for
continual operation installations, a twelve (12) hour duration for Industrial
and Commercial applications and a six (6) hour duration for Residential
applications should be considered.
4. Product maintenance – In line with the relevant design standards and to
protect your investment, it is important to have in place a routine cleaning
program that reflects the installation environment and maintains the product
in a clean and functional condition.
IMPORTANT – The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable cannot be replaced and the luminaire must be destroyed.
5. Adverse, corrosive and coastal installation environments – Unless the
product is specifically designated for such applications in these installation
instructions, which is supported by a professional maintenance program;
installation of equipment in such environments is not recommended.
6. Dimming products – Dimming circuits and product compatibility must be
validated by the installer before installation; SAL cannot be responsible for
third party changes in dimmer compatibility.
7. Suspended products – For installation safety, any suspended products must
NOT be installed in high air movement spaces or locations subject to impact.
8. Light source replacements – (Non-replaceable light sources) – The light
source of the product is deemed not replaceable, when the product reaches its
end life, it must be replaced by a qualified installer. (Non-user replaceable
light sources) – The light source of the product must only be replaced by the
manufacturer or qualified installer.
9. Interior downlights and sensors with remote drivers and electrical
accessories – The mounting facilities provided for the transformer/driver (if
any), need only be utilized if in the application of the product is required
by AS3000. Drivers are not designed for installation environments that
restrict conventional airflow.
10. Ripple injection, induced flicker (QLD & NSW regions) – Installations
subject to off-peak ripple induced flicker, (which are beyond the manufactures
control), should strongly consider the use of circuit filtering products, or
for interior downlight installations, the use of products designed to block
the signal interferences, such as the SAL SFI series.
11. Floodlight products – Unless nominated aiming restrictions or
installation parameters apply, products are designed for installation
environments between ground and 15 metres in height, subject to the desired
optical performance being achieved. For floodlight installation environments
that have restricted access (eg: columns and roof-lines) which are subject to
unstable electrical supply or electrical surges (which void warranty),
consideration of the installation of an independent surge protector is
strongly recommended.
12. Emergency enabled products – In the interest of transport and safety,
emergency products are supplied with the battery disconnected. In addition to
specific emergency commissioning instructions, this battery MUST be connected
at the time of installation. Continual use in emergency mode greater than 240
hours without recharge, will result in battery failure and void battery
warranty.
13. Specific installation procedures (if any) – this device must be installed
by a licensed electrician.
PIR Sensor
Optional to order:
Remote control function TRADE USE ONLY – WARNING; the controller device contains a button battery, keep out of reach of children
14. Warranty – In accordance with SAL’s standard terms and conditions of
sale, SAL warrant this product to be free from defects in materials and or
workmanship for a period as stated below for goods not subject to incorrect
installation, maintenance, operation, mishandling, environmental, unauthorised
modifications or electrical operating conditions outside the nominated product
specification as detailed in these installation instructions.
The benefits to you given by this warranty are in addition to other rights and
remedies you have under law. Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure.
Warranty term – Residential usage (24) months, Commercial usage (24) months, Replaceable Lamps (where supplied) (12) months and Lithium batteries where supplied (24) months from date of purchase. For New Zealand, please refer to www.sal.co.nz for warranty conditions and service.
How to make a claim?
Step # 1 – Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.
Step # 2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;
NSW | ACT| – SAL National Pty Ltd, 40 Biloela Street Villawood NSW 2163| | P #
02 9723 3099
---|---|---
QLD| – SAL National Pty Ltd, 36 Whitelaw Place Richlands QLD 4077| | P # 07
3879 5999
VICT | TAS| – SAL National Pty Ltd, 46-48 Keys Road Moorabbin Victoria 3189| |
P # 03 9532 3168
SA | NT| – SAL National Pty Ltd, Unit 1, 9 Alfred Avenue, Beverley SA 5009| |
P # 08 7084 1958
WA| – SAL National Pty Ltd, 29 Beringarra Av Malaga WA 6090| | P # 08 9248
7458
NZ| – Hamer, 130 Bush Road, Albany, Auckland, 0632| | P # 0800 239 239
Step # 3 – Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be returned to SAL as per the above nominated locations.
Step # 4 – Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of installation, product removal, return freight and or testing fees are not the responsibility of SAL.
SAL National Pty Ltd.
40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474
Copyright SAL V17 APR 2023
www.sal.net.au
FAQ
Q: Can the LED be replaced by the user?
A: No, the LED is not user-replaceable. Please refer to clause 8 for more information.
Q: Is the product dimmable?
A: No, the product is not dimmable. Refer to specifications for more details.
Q: What is the IP rating of the product?
A: The product has an IP65 rating, suitable for exterior residential and commercial spaces.