electriQ CD12P Compressor Dehumidifier With Digital Humidistat User Manual

June 6, 2024
ElectriQ

electriQ logo

electriQ CD12P Compressor Dehumidifier With Digital Humidistat User Manual

electriQ CD12P Compressor Dehumidifier With Digital
Humidistat

CD12P – 12 Litres per day
Thank you for choosing electriQ.
Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals

SAFETY INSTRUCTIONS

  • Carefully read the instructions before operating the unit.
  • This appliance is for indoor use only and is only intended for use in a domestic environment or similar. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property.
  • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
  • Installation must be in accordance with regulations of the country where the unit is used.
  • If you are in any doubt about the suitability of your electrical supply have it checked and if necessary, modified by a qualified electrician.
  • This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – use it with care.
  • Disconnect the power before dismantling, assembling or cleaning.
  • Avoid touching any moving parts of the appliance.
  • Never insert fingers, pencils or any other objects though the guard.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Do not leave children unsupervised with this appliance.
  • Do not clean the unit by spraying it or immersing it in water.
  • Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician.
  • Never operate this appliance if the power cord or plug is damaged.
  • Ensure the power cord is not stretched or exposed to sharp objects/edges.
  • A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
  • Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty.
  • Do not use the appliance for any purpose other than its intended use.
  • Do not tilt the unit while in use. The unit is design to work only in a vertical position.
  • This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit following transportation.
  • Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor.
  • Never use the plug as a switch to start or stop the dehumidifier. Use the provided ON/OFF button located on the control panel.
  • Always place the unit on a dry and stable surface.
  • The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH.
  • Do not dry laundry above the unit to prevent water entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier.
  • Before moving the appliance the water tank should be emptied.
  • The handle on the appliance is designed to aid in its movement and should not be used to support the full weight of the dehumidifier. When carrying the unit, it should be kept upright and suifficiently supported from its base.
  • The handle should not be used if there are any signs of damage to its fixings.
  • The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
  • R290 refrigerant gas complies with European environmental directives.
  • R290 has a low GWP (Global Warming Potential) of 3.
  • The CD12P contains about 50g of R290 refrigerant gas.
  • Do not use or store the appliance in an unventilated space with an area smaller than 4m2 per unit.
  • If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
  • Refrigerant gas may be odourless.
  • Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
  • Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
  • The refrigerant system should not be perforated or punctured.
  • Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
  • Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it.
  • Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance.
  • This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable.

ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS

  • Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power on.
  • For maximum performance the minimum distance from a wall or objects should be 20 cm
  • Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately).
  • Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. Vacuum both mesh and optional HEPA filter and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.

VISUAL SAFETY GUIDE
WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER

FIG 1 VISUAL SAFETY GUIDE

INFORMATION ON INDOOR POLLUTANTS

VOC (Volatile Organic Compound): VOCs come from motor vehicle exhausts, gasoline vapour, pollutants such as formaldehyde, ammonia and many other common and chemical solvents such as paints and glues, or can be a by-product of mould growth. VOCs cause irritation to the eyes and or nose as well as causing headaches, nausea and even potential damage to the central nervous system. Pressed wood furniture, newly decorated rooms, paint and cleaning solvents are common sources of VOCs.

Mould / Fungus: These can affect our respiratory system and cause allergic reactions, like a runny nose, eye and throat irritation, headaches, fatigue and aggravation of asthma.
Other indoor pollutants include bacteria, viruses, dust mites and pollen.

Emissions from electronic office equipment: Many studies, including those from EPA and the University of California Berkley, have reported that emissions from office equipment such as computers and printers, include VOCs, ultra-fine particles and ozone. These emissions have been proven to have a negative effect on the health of many people which can be reduced by using an air purifier.

Using HEPA and Carbon filters: An effective HEPA filter is absolutely necessary to remove particles, even at a microscopic level; it ensures that the particles are not spread.
The carbon filter will absorb unpleasant odours and reduce the VOC content in the air.

APPLIANCE DIAGRAM

FIG 2 APPLIANCE DIAGRAM

FIG 3 APPLIANCE DIAGRAM

OPTIONAL FILTERS

FIG 4 OPTIONAL FILTERS

Note: Diagrams are for illustrative purposes only. The design of the parts may vary from what is shown.

FEATURES

Your dehumidifier belongs to the electriQ dehumidifier range featuring power saving logic.

  1. Easy to use controls
  2. Cost effective way to combat mould, condensation and damp
  3. Optional HEPA and Carbon filters for air purification
  4. Dries laundry more efficiently than a tumble dryer
  5. Designed to complement any modern space
  6. Castors for improved mobility
  7. Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display
  8. 24 hours start / stop timer
  9. Tank operation or permanent drainage option with splash proof tank
  10. Tank full alarm & auto-stop function

The CD12P dehumidifier uses compressor technology to extract water from the environment. Compressor dehumidifiers are ideal for normal domestic or office environments which are heated during the winter months and maintain a temperature above 12-15⁰C.

This dehumidifier is easy to move around on castors and is designed to extract unwanted humidity while saving money due to it’s power saving logic. It features an intelligent humidistat where the desired relative humidity can be adjusted in increments of 5% between 35 and 80% ensuring the air in your room is not too dry and that power is not wasted.

INSTALLATION

Remove any water from within the water tank before starting the unit. In order to save energy do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs.

TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running.

FITTING THE OPTIONAL FILTERS

The optional filters can be placed in the appliance before use. The optional HEPA filter is fitted into the rear of the filter housing. The optional Carbon filter is placed between the unit and the filter housing.

FIG 5 FITTING THE OPTIONAL FILTERS

CONTROL PANEL

FIG 6 CONTROL PANEL

FIG 7 CONTROL PANEL

FIG 8 CONTROL PANEL

FIG 9 CONTROL PANEL

FIG 10 CONTROL PANEL

HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY

The led indicator performs the following functions:

  1. When the unit is plugged in, it will indicate the humidity level of the room.
  2. When the UP and DOWN buttons are pressed, it will indicate the desired humidity currently set.
  3. When the timer is programmed will show the duration.

Notes: When humidity level is outside the normal operational parameters will show LO/HI. If ambient humidity is lower than 20%, it will show “LO” If ambient humidity is higher than 90%, it will show “HI”.

QUICK REFERENCE GUIDE

FIG 12 QUICK REFERENCE GUIDE

FIG 13 QUICK REFERENCE GUIDE

During operation the compressor will operate until the desired humidity is reached and then will stop. The fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured.

To achieve drier air, or while drying laundry use the DOWN button to select a lower desired humidity (e.g. 35-45%).

LAUNDRY MODE: When drying clothes it is advised for the dehumidifier to operate continuously with maximum water extraction until the water tank is full. Set the unit to the Smart mode, and set the desired humidity level between 35%-50%. 35% is very dry and is hardly achievable in a UK domestic environment. As such the unit will work until the water tank is full when set to 35%. Do not place clothes directly over any of the vents on the dehumidifier. Make sure that there is nothing blocking the hot air exhaust air flow and for best results place the laundry within 1.5 meters of the dehumidifier.

NOTES:

  • If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended for long normal operation in a domestic or office environment.
  • To allow more moisture in the air, press the up button and set to a higher desired humidity (e.g. 60-70%).
  • We recommend setting the Humidity to 50-55%. This is great for domestic operation and dry storage.
  • Setting the humidity to 60% is great for personal comfort and applications where 50% RH is considered too dry.
  • Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed without the need to reduce the humidity further.

OTHER FEATURES AND INDICATORS

TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation.

AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings.

  • When the unit is running in a room with a temperature between 5oC and 12oC, it will enter defrost mode roughly every 30 minutes.
  • When the unit is running in a room with a temperature between 12⁰C and 20⁰C, it will enter the defrost mode roughly every 45 minutes.

HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION

  • When the humidity of the room is 2% lower than the desired humidity the compressor will turn off automatically but the fan will continue to operate to ensure that the air within the room is not stale. The unit will use only a minimal amount of energy in fan mode.
  • When the humidity of the room is equal to or higher than the desired humidity the compressor will restart after a 3 minutes delay to protect the compressor.

AUTO-RESTART
If the unit stops unexpectedly due to the power cut, it will restart with the previous function selected automatically when the power resumes, and the 3 minute compressor protection has elapsed.

POWER
After the unit has stopped, to protect the compressor it is not recommended to resume operation for at least 10 minutes. Operation can resume after this period lapses. When the unit is restarted there is a 3 minute delay before compressor will start.

LIGHTWEIGHT PORTABLE DESIGN ON CASTORS
The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit make it easy to move from room to room.

Your dehumidifier contains an advanced micro-CPU controlled device which is capable of self-diagnostics. The LCD display may also show the error and protections codes.

POSITIONING THE DEHUMIDIFIER

A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit.

Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small office applications and any commercial or industrial use will invalidate the warranty.

FIG 14 POSITIONING THE DEHUMIDIFIER

Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment. Do not use outdoors.

Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior doors ajar to allow air circulation.

Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date. For the most effective use, run your dehumidifier with external doors and windows kept closed. Please note the unit should not be placed directly against a radiator or other heat source.

Before moving the appliance the water tank should be emptied. The handle on the appliance is designed to aid in its movement and should not be used to support the full weight of the dehumidifier. When carrying the unit, it should be kept upright and suifficiently supported from its base. The handle should not be used if there is any signs of damage to its fixings.

When positioning your electriQ dehumidifier, ensure that it is placed clear of any obstacle that may limit the air movement. Place the dehumidifier on a flat dry surface.

Note: Do not force castors to move over carpet or uneven surfaces, nor move the unit with water in the tank as it may tip over and spill water.

WATER DRAINAGE

When the water tank is full, the unit will stop automatically. When this happens the TANK FULL light will illuminate on the control panel.

NOTE: Only empty the water tank when it is full or before moving or storing the unit.
There are two ways to dispense collected water.

1. USE THE TANK
When the tank is full, the unit will automatically stop running, and the Tank Full indicator will flash. Slowly pull out the tank. Grip the tank by its handle securely, and carefully pull it out. Empty the water tank and reinsert it into the dehumidifier. The tank must be in place and securely seated for the dehumidifier to operate again. The dehumidifier will re-start when the tank is restored to its correct position.

FIG 15 USE THE TANK

NOTES:
When you remove the water tank, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate.

Do not remove any parts from the water tank or tank enclosure. The water full sensor will no longer be able to detect the water level correctly and water may leak from the water tank.

2. CONTINUOUS DRAINAGE
Water can be automatically plumbed in or drained into a sink, a larger container or through the wall into an outside drain by attaching a pipe to the unit (10 mm internal diameter) (not included). Insert the pipe into the drain outlet at the back of the unit as shown here.

FIG 16 CONTINUOUS DRAINAGE

Make sure the connection between pipe and the drain outlet is tight and does not leak. Then direct the pipe to a suitable drainage point. This unit uses gravity to dispose of water hence the drain should be lower than the water outlet on the unit. Put the tank back. Be sure to run the water pipe downward and to let the water flow out smoothly. Do not kink or bend the pipe.

The permanent drain can be used in conjunction with a water pump (e.g. when draining from a cellar) to lift the water upwards.

CARE AND MAINTENANCE

Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.

1. CLEAN THE GRILLE AND CASE
Use water and a mild detergent to clean the washable mesh filter. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel.

Remove the filter housing. If the optional filters are fitted, remove them from the frame and hoover gently approximately every 2-3 weeks.

If the mesh filter is dirty hoover it, if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit. When filter cleaning is finished and filters are dry placed them back into the unit. The optional filters should be replaced every 3 – 6 months.

NOTE: While the HEPA and Carbon filters are optional, never run the unit without the mesh filter housing correctly inserted.

2. CLEAN THE WATER TANK
Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially fill the tank with clean water and add a little mild detergent. Swish it around and than empty the tank and rinse.

NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted securely into dehumidifier in order to restart operation.

END OF SEASON MAINTENANCE

  1. Empty and clean the water tank.
  2. Clean the unit and the filters as per cleaning procedure above.
  3. Coil the power cord on the special cord storage rest at the back of the unit.
  4. Cover the unit and keep it in a dry place.

TROUBLESHOOTING

FIG 19 TROUBLESHOOTING

FIG 20 TROUBLESHOOTING

FIG 21 TROUBLESHOOTING

FREQUENTLY ASKED QUESTIONS

Why doesn’t the dehumidifier seem to extract much water if the temperature is low?
This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range.

Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To rectify: empty the tank and carefully place the tank back in the unit. Also the unit may be running in dehumidifying mode with a low room temperature. Please check if the room temperature is lower than 5⁰C. If so, the unit will stop working while in dehumidifying mode. (unit may be defrosting).
The ambient operating range is between 5⁰C and 35⁰C with a relative humidity ranging from 30% to 80%. For maximum efficiency use the unit between 15⁰C and 32⁰C.

Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity.
During the cold cycle there should be cold air coming out of the unit.
During the hot cycle hot dry air should be coming out of the outlet grill.

TECHNICAL DATA

FIG 22 TECHNICAL DATA

FIG 23 TECHNICAL DATA

electriQ UK SUPPORT

www.electriQ.co.uk/support

Please, for your own convenience, make these simple checks before calling the service line.

  1. Has the unit been standing upright for at least 2 hours?

  2. Is the unit plugged into the mains?

  3. Is the fuse OK?

  4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
    Check if the water tank is full.

  5. Was the troubleshooting guide followed?

If the unit still fails to operate call: 0330 390 3061 or complete the online form
Office hours: 9AM – 5PM Monday to Friday
Unit J6, Lowfields Business Park,
Lowfields Way, Elland
West Yorkshire, HX5 9DA

Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ElectriQ User Manuals

Related Manuals