ROSIERES HOBS Instructions
- June 7, 2024
- ROSIERES
Table of Contents
- SAFETY INSTURUCTIONS
- INSTRUCTIONS FOR THE INSTALLER
- ELECTRICAL CONNECTION (FOR U.K. ONLY)
- USE OF HOB – USER INSTRUCTIONS
- AFTERCARE
- PROTECTION OF THE ENVIRONMENT
- DECLARATION OF COMPLIANCE
- HOBS GAS TYPE
- Efficiency Declaration 2016/426
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ROSIERES HOBS
SAFETY INSTURUCTIONS
We recommend you keep the instructions for installation and use for later
reference, and before installing the hob, note its serial number in case you
need to get help from the after sales service.
WARNING: the appliance and its accessible parts become hot during use.
Care should be taken to avoid touching heating elements. Children under 8
years of age must be kept away from the appliance unless they are continuously
supervised.
WARNING: use only hob guards designed by the Manufacturer of the cooking
appliance or indicated by the Manufacturer of the appliance in the
instructions for use as suitable or hob guards incorporated in the appliance.
The use of inappropriate guards can cause accidents.
WARNING: unattended cooking on a hob with fat or oil can be dangerous and
may result in fire.
NEVER try to extinguish a fire with water, but switch off the appliance
and then cover flame e.g. with a lid or a fire blanket.
WARNING: danger of fire: do not store items on the cooking surfaces.
WARNING: if the surface is cracked, do not touch the glass and switch off
the appliance to avoid the possibility of electric shock.
This appliance can be used by children aged from 8 years and above and people
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children should be supervised to ensure that they do not play with the
appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
CAUTION: the cooking process must be supervised. A short term cooking
process has to be supervised continuously.
It is strongly recommended to keep children away from the cooking zones while
they are in operation or when they are switched off, so long as the residual
heat indicator is on, in order to prevent the risks of serious burns.
This appliance is not intended to be operated by means of an external timer or
separate remote control system.
If present do not to stare into halogen lamp hob elements.
Connect a plug to the supply cable that is able to bear the voltage, current
and load indicated on the tag and having the earth contact. The socket must be
suitable for the load indicated on the tag and must be having the earth
contact connected and in operation. The earth conductor is yellow-green in
color. This operation should be carried out by a suitably qualified
professional. In case of incompatibility between the socket and the appliance
plug, ask a qualified electrician to substitute the socket with another
suitable type.
The plug and the socket must be conformed to the current norms of the
installation country.
Connection to the power source can also be made by placing an omnipolar
breaker between the appliance and the power source that can bear the maximum
connected load and that is in line with current legislation.
The yellow-green earth cable should not be interrupted by the breaker. The
socket or omni polar breaker used for the connection should be easily
accessible when the appliance is installed.
The disconnection may be achieved by having the plug accessible or by
incorporating a switch in the fixed wiring in accordance with the wiring
rules.
If the supply cord is damaged, it must be replaced by Manufacturer, its
service agent or similarly qualified people in order to avoid a hazard. The
earth conductor (yellow-green) must be longer than 10 mm on the terminal block
side. The internal conductors section should be appropriate to the power
absorbed by the hob (indicated on the tag). The type of power cable must be
H05 GG-F for 60-75cm hobs or H05- V2V2-F for 75cm hobs
Do not put metallic objects such as knives, forks, spoons or lids on the hob.
They could heat up.
Aluminum foil and plastic pans must not be placed on heating zones.
After every use, some cleaning of the hob is necessary to prevent the build-up
of dirt and grease. If left, this is recooked when the hob is used and burns
giving off smoke and unpleasant smells, not to mention the risks of fire
propagation.
Never use a steam or high pressure spray to clean the appliance.
Do not touch the heat zones during operation or for a while after use.
Never cook food directly on the glass ceramic hob.
Always use the appropriate cookware. Always place the pan in the center of the
unit that you are cooking on.
Do not place anything on control panel.
Do not use the hob as a working surface.
Do not use the surface as a cutting board.
Do not store heavy items above the hob. If they
drop onto the hob, they may cause damage.
Do not use the hob for storage of any items.
Do not slide cookware across the hob.
No additional operation/setting is required in order to operate the appliance
at the rated frequencies.
In case of hotplate glass breakage:
Shut immediately off all burners and electrical heating element and isolate
the appliance from the power supply.
Do not touch the appliance surface.
Do not use the appliance.
INSTRUCTIONS FOR THE INSTALLER
INSTALLING A DOMESTIC APPLIANCE CAN BE A COMPLICATED OPERATION WHICH IF NOT CARRIED OUT CORRECTLY, CAN SERIOUSLY AFFECT CONSUMER SAFETY. IT IS FOR THIS REASON THAT THE TASK SHOULD BE UNDERTAKEN BY A PROFESSIONALLY QUALIFIED PERSON WHO WILL CARRY IT OUT IN ACCORDANCE WITH THE TECHNICAL REGULATIONS IN FORCE. IN THE EVENT THAT THIS ADVICE IS IGNORED AND THE INSTALLATION IS CARRIED OUT BY AN UNQUALIFIED PERSON, THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR ANY TECHNICAL FAILURE OF THE PRODUCT WHETHER OR NOT IT RESULTS IN DAMAGE TO GOODS OR INJURY TO INDIVIDUALS.
BUILDING IN
The hob may be installed in any worktop which is heat resistant to a
temperature of 100°C, and has a thickness of 25-45 mm. The dimensions of the
insert to be cut out of the worktop are in shown in Figure 2.
When there is an accessible space between the built-in hob and the cavity
below, a dividing wall made of insulating material should be inserted (wood or
a similar material) (Figure 2).
If the Hob is fitted next to a cabinet on either side, the distance between
the Hob and the cabinet must be at least 17 cm (60cm) or 25 cm (75cm) ; while
the distance between the hob and the rear (see Figure 2) wall must be at
least . 70 mm.
The distance between the hob and any other unit or appliance above it (e.g. An
extractor hood) must be no less than 70 cm.
(Figure 4) Metal objects in the drawer may reach high temperatures due to
air recirculation. It is therefore recommended to use an intermediate wood
panel.
Important – The diagram in figure 1 shows how the sealant should be
applied.
The Hob unit is fitted by attaching the Fixing Clamps supplied, using the
holes at the base of the unit.
When a 60 cm hob or a 75 cm hob is fitted over a built in oven, the latter
must be fan cooled.
SUITABLE LOCATION
This appliance must be installed in accordance with the regulations in force
and only used in a well ventilated space. Read the instructions before
installing or using this appliance.
A gas-powered cooking appliance produces heat and humidity in the area in
which it is installed. For this reason you should ensure good ventilation
either by keeping all natural air passages open or by installing an extractor
hood with an exhaust flue. Intensive and prolonged use of the appliance may
require extra ventilation, such as the opening of a window or an increase in
speed of the electric fan, if you have one.
If a hood can not be installed, an electric fan should be fitted to an outside
wall or window to ensure that there is adequate ventilation.
The electric fan should be able to carry out a complete change of air in the
kitchen 3-5 times every hour. The installer should follow the relevant
national standards.
ELECTRICAL CONNECTION (FOR U.K. ONLY)
Warning – this appliance must be earthed
This appliance is designed for domestic use only. Connection to the main
supply must be made by a competent electrician, ensuring that all current
regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a 3 pin
13 amp plug/socket is not suitable. A double pole switch must be provided and
the circuit must have appropriate fuse protection.
Further details of the power requirement of the individual product will be
found in the users’ instruction and on the appliance rating plate. In the case
of built-in product you are advised, should you wish to use a longer cable
than the one supplied, that a suitably rated heat resistant type must be used.
The wiring must be connected to the mains supply as follows:
CONNECT TO SPUR TERMINAL
Green & Yellow Wire Earth Connection
Blue Wire Neutral Connection
Brown Wire Live Connection
Note: We do not advocate the use of earth leakage devices with electric
cooking appliances installed to spur points because of the «nuisance tripping»
which may occur. You are again reminded that the appliance must be correctly
earthed, the manufacturer declines any responsibility for any event occurring
as a result of incorrect electrical installation.
ELECTRICAL CONNECTION
Check the data on the rating plate, located on the outside of the unit, to
ensure that the supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not complied
with, the Manufacturer will not be responsible for any damage caused to
persons or property. If a plug is not already attached, fit a plug appropriate
to the load indicated on the rating plate. The earth wire is coloured
yellow/green. The plug should always be accessible.
Where the Hob is connected direct to the electricity supply, a circuit breaker
must be fitted.
If the power supply cord is damaged this is to be replaced by a qualified
engineer so as to prevent any potential risk.
The earth wire ( green and yellow coloured ) must be at least 10 mm longer
than the live and neutral wires.
The section of the cable used must be of the correct size in relation to the
absorbed power of the hob.
Please check rating plate for the power details and ensure that the power
supply cord is of the type 3×0.75 mm² H05 GG-F for 60-75cm hobs or H05-V2V2-F
for 75cm hobs.
If an appliance is not fitted with a supply cord and a plug, or with other means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, the instructions shall state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
GAS CONNECTION
These instructions are for qualified personnel, installation of equipment must
be in line with the relevant national standard. (For U.K. only: by law the gas
installation\commissioning must be carried out by a “Gas Safe” installer)
All work must be carried out with the electricity supply disconnected.
The rating plate on the hob shows the type of gas with which it is designed to
be used. Connection to the mains gas supply or gas cylinder should be carried
out after having checked that it is regulated for the type of gas with which
it will be supplied. If it is not correctly regulated see the instructions in
the following paragraphs to change gas setting.
For liquid gas (cylinder gas) use pressure regulators which comply with the
relevant national standards.
Use only pipes, washers and sealing washers which comply with the relevant
national standards.
For some models a conic link is furnished to outfit for the installation in
the countries where this type of link is obligatory; in picture 8 it is
pointed out how to recognize the different types of links (CY = cylindrical,
CO = conic). In every case the cylindrical part of the link has to be
connected to the hob.
When connecting the hob to the gas supply via use of flexible hoses please
ensure that the maximum distance covered by the hose does not exceed 2 metres.
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit (e.g. a drawer) and does not
pass through any space where it may become crushed/ kinked or damaged in any
way.
To prevent any potential damage to the hob please carry out the installation
following this sequence (picture 6):
-
As illustrated, assemble parts in sequence:
A: 1/2 Male Adaptor Cylindrical
B: 1/2 Seal
C: 1/2 Female Gas Adaptor Conical-Cylindrical or Cylindirical-Cylindirical -
Tighten the joints with the spanner, remembering to twist the pipes into position.
-
Attach fitting C to mains gas supply using rigid copper pipe or flexible steel pipe.
IMPORTANT: carry out a final check for leaks on the pipe connections using
a soapy solution. NEVER USE A FLAME.
Also, make sure that the flexible pipe cannot come into contact with a
moving part of the cabinet (eg.adrawer) and that it is not situated where it
could be damaged.
Warning: If gas can be smelt in the vicinity of this appliance turn off
the gas supply to the appliance and call the engineer directly. Do not search
for a leak with a naked flame.
ADAPTING THE HOB TO DIFFERENT TYPES OF GAS
To adapt the Hob for use with different types of gas, carry out the following instructions:
- Remove the grids and burners
- Insert on hexagonal spanner (7 mm) into the burner suppor t (Figure7)
- Unscrew the injector and replace it with one suitable for the gas to be used (see gas type table)
REGULATING THE MINIMUM FLAME
After lighting the burners, turn the control knob to the minimum setting and
then remove the knob (this can easily be removed by applying gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw can be adjusted
as in Figure 8. Turning the screw clockwise reduces the gas flow, whilst
turning it anticlockwise increases the flow – Use this adjustment to obtain a
flame of approximately 3 to 4 mm in length and then replace the control knob.
When the gas supply available is LPG – the screw to set the idle flame must be
turned (clockwise) to the end stop.
When you have carried out the new gas regulation, replace the old gas rating
plate on your appliance with one (supplied with hob) suitable for the type of
gas for which it has been regulated.
USE OF HOB – USER INSTRUCTIONS
This appliance must only be used for the purpose for which it is intended,
domestic cooking, and any other use will be considered improper and could
therefore be dangerous. The Manufacturer will not be responsible for any
damage or loss resulting from improper use.
Before using burner, be sure, grid perimeters center the burner as below
figure.
If you are using Cast Iron Grids; underneath the grid, position of it is
stated. Be sure for the exact grid is used in correct position.
USING THE GAS BURNER
Prior to switching on the gas hob ensure that the burners and burner caps are correctly placed within their position.
This hob is fitted with electronic ignition to ignite the burner.
To ignite the burners carry out the following:
° push in and turn the knob anticlockwise to the larger flame symbol and keep
pushed 5 s after ignition.
The ignition system will continue to generate sparks as long as the control
knob is being pressed
Warning: If there is no electricity on appliance to ignite the burner a
match or a lighter should be used caring out the following:
°place a lighted match or lighter close to the burner °push in and turn the
knob anticlockwise to the larger flame symbol and keep pushed 5 s after
ignition.
Warning: In any case If after 5 s the burner has not lit, stop operating the device and wait at least 1 min before attempting a further ignition of the burner.
GENERAL ADVISE
For best results, use cooking vessels with a flat surface. The size of the surface should match the gas burner side as follows. Table A.
Burner Type
| Ø pan/pot (cm)| Power (kW)| G20 20 mbar (methane)|
G30 28-30 mbar (LPG)
---|---|---|---|---
AUX Auxiliary
| 10 – 18| 1,00| 95 l/h| 73 g/h
SR Semi Rapid| 12 – 22| 1,75| 167 l/h|
127 g/h
R Rapid
| 16 – 26| 2,70| 257 l/h| 196 g/h
DC 4 kW Mono| 16 – 26| 4,00| 381 l/h|
291 g/h
DC 4,2 kW Mono
| 16 – 26| 4,20 NG
4,00 LPG| 400 l/h| 291 g/h
DC 4,5 kW Mono| 16 – 26| 4,50| 429 l/h|
327 g/h
The gas burner should be regulated so that the flame does not overlap the base
of the pan. Vessels with a concave or convex base should not be used.
WARNING: If a flame is accidentally extinguished, turn the knob to the
off position and do not attempt to re-ignite if for at least 1 minute.
If over the years the gas taps become stiff to turn it is necessary to
lubricate them.
Such operation must be carried out only by qualified Service Engineers.
MAINTENANCE AND CLEANING
Before cleaning the hob, ensure the appliance has cooled down.
Remove the plug from the socket or (if connected directly) switch off the
electricity supply.
Cleaning and user maintenance shall not be made by children without supervision
Never use abrasives, corrosive detergents, bleaching agents or acids. Avoid any acid or alkaline substances (lemon, juice, vinegar etc.) on the enamelled, varnished or stainless steel sections.
When cleaning the enamelled, varnished or chrome sections, use warm soapy water or a non caustic detergent. For stainless steel use an appropriate cleaning solution.
The burners can be cleaned with soapy water. To restore their original shine,
use a household stainless steel cleaner. After cleaning, dry the burners and
replace.
It is important the Burners are replaced correctly.
Chromed grids and burners
Chromed grids and burners have a tendency to discolour with use.
This does not jeopardize the functionality of the hob.
Our After Sales Service Centre can provide spare parts if required.
AFTERCARE
Before calling out a Service Engineer please check the following:
- that the plug is correctly inserted and fused;
- that the gas supply is not faulty.
If the fault cannot be detected:
Switch off the appliance and call the After Service Centre. DO NOT TAMPER WITH
THE APPLIANCE.
PROTECTION OF THE ENVIRONMENT
This appliance is labelled in accordance with European Directive 2012/19/EU
regarding electric and electronic appliances (WEEE). The WEEE contain both
polluting substances (that can have a negative effect on the environment) and
base elements (that can be reused). It is important that the WEEE undergo
specific treatments to correctly remove and dispose of the pollutants and
recover all the materials. Individuals can play an important role in ensuring
that the WEEE do not become an environmental problem; it is essential to
follow a few basic rules:
– The WEEE should not be treated as domestic waste;
– The WEEE should be taken to dedicated collection areas managed by the town
council or a registered company.
In many countries, domestic collections may be available for large WEEEs. When
you buy a new appliance, the old one can be returned to the vendor who must
accept it free of charge as a one-off, as long as the appliance is of an
equivalent type and has the same functions as the purchased appliance.
SAVING AND RESPECTING THE ENVIRONMENT
Where possible use lid to cover the pan. Regulate the flame to not overlap the
diameter of the pan.
DECLARATION OF COMPLIANCE
The appliance complies with European Directive 2009/142/EC (GAD) and starting from 21/04/2018 with Gas Appliances Regulation 2016/426 (GAR).
By placing the mark on the product, we are confirming compliance to all relevant European safety, health and environmental requirements which are applicable in legislation for this product.
Table 1
Burner Plate|
4Gas – L1 – STD
| 4Gas – L2 – 3 GAS| 4Gas – L3 – Big Rear|
5Gas – L4 – Central
---|---|---|---|---
Burner|
AUX/SR/2R
| SR/R/DC| AUX/SR/R/DC|
AUX/SR/2R/DC
Type|
PVUH60MF
| PVUH60MF| PVUH60MF|
PVUH75MF
FFD|
YES
| YES| YES|
YES
AUX 1kW|
1
| 1| 1|
1
SR 1,75 kW|
2
| –| 1|
1
R 2,7 kW|
1
| 1| 1|
2
DC 4 kW Mono|
–
| –| 1|
–
DC 4,2 kW Mono|
–
| –| –|
–
DC 4,5 kW Mono|
–
| 1| –|
1
Nominal Heat Input|
7,2kW
| 8,2kW| 9,45kW|
12,65kW
G20/20 mbar|
686 l/h
| 781 l/h| 900 l/h|
1204 l/h
G30/28-30 mbar|
524 g/h
| 596 g/h| 688 g/h|
920 g/h
Installation Class|
3
| 3| 3|
3
Voltage V/Frequency Hz|
220-240V 50/60Hz
| 220-240V 50/60Hz| 220-240V 50/60Hz|
220-240V 50/60Hz
Electrical Input Power|
1
| 1| 1|
1
Electric Ignition|
YES
| YES| YES|
YES
Product Dimension|
595x505x42
| 595x505x42| 595x505x42|
745x505x42
HOBS GAS TYPE
|
Gas Type
| G20| G20| G25.1| G25.3| G30/G31| G30/G31| G30/G31
---|---|---|---|---|---|---|---|---
Gas Pressure| 20 mbar| 25 mbar| 25 mbar| 25 mbar| 28-30 mbar|
37 mbar
| 50 mbar
Burners
| Max (kW)| Min (kW)| Injector NG| Injector NG| Injector NG| Injector NG|
Injector LPG| Injector LPG| Injector LPG
Max – Min| Max – Min| Max – Min| Max – Min| Max – Min|
Max – Min
| Max – Min
AUX
| 1| 0,3| 72X
(1kW-0.3kW)| 70X
(1kW-0.3kW)| 74F1
(1kW-0.3kW)| 72F1
(1kW-0.3kW)| 50
(73g/h-22g/h)| 46
(73g/h-25g/h)
| 46H2
(73g/h-29g/h)
SR| 1,75| 0,5| 97Z (1.75kW-0.5kW)| 91Z (1.75kW-0.5kW)| 98Y (1.75kW-0.5kW)|
102F3 (1.75kW-0.5kW)| 65
(127g/h-36g/h)|
61
(127g/h-40g/h)
| 58M
(127g/h-44g/h)
R
| 2,7| 0,8| 112Y
(2.7kW-0.8kW)| 110F3
(2.7kW-0.8kW)| 120F2
(2.7kW-0.8kW)| 115F2
(2.7kW-0.8kW)
| 80
(196g/h-58g/h)| 78
(196g/h-62g/h)| 73S
(196g/h-69g/h)
DC 4 kW MONO| 4| 1,8| 151H3
(4kW-1.8kW)| 145H3
(4kW-1.8kW)| 150F3
(4kW-1.8kW)| 146F3
(4kW-1.8kW)| 100
(286g/h-131g/h)|
94
(286g/h-138g/h)
| 78 F4
(286g/h-145g/h)
DC 4,2 kW MONO
| NG 4,2 – LPG 4| 2,3| 153H3
(4,2kW-2.3kW)| 148H3
(4,2kW-2.3kW)| 154F3
(4,2kW-2.3kW)| 148F3
(4,2kW-2.3kW)| 100
(286g/h-167g/h)| 94
(286g/h-175g/h)| 78 F4
(286g/h-189g/h)
DC 4,5 kW MONO| 4,5| 2,3| 155H3
(4,5kW-2.3kW)| 150H3
(4,5kW-2.3kW)| 157F3
(4,5kW-2.3kW)| 150F3
(4,5kW-2.3kW)| 107
(327g/h-167g/h)|
100
(327g/h-175g/h)
| 95 – 6
(327g/h-189g/h)
Gas Categories
| II2E+3+| II2H3+| II2H3B/P
---|---|---|---
G20/G25 20/25mbar 2E+
| G20 20mbar 2H|
G20 20mbar 2H
G30/G31 28-30/37mbar 3+| G30/G31 28-30/37mbar 3+|
G30/G31 30/30mbar 3B/P
Countries
| BE,FR| CY,CZ,GB,GR,IE,IT,PT,SI,ES,TR,CH|
BG,HR,DK,EE,FI,LV,LT,NO,RO,SK,SE,CZ,SI,TR
Gas Categories
|
II2H3B/P
| II2EK3B/P| II2HS3B/P| II2E3B/P| II2E3B/P
---|---|---|---|---|---
G20 20mbar 2H| G20 20mbar 2E| G20 20mbar 2H| G20 20mbar 2E|
G20 20mbar 2E
G30/G31 50/50mbar 3B/P
| G25.3 25mbar 2K| G25.1 25mbar 2S| G30/G31 37/37mbar 3B/P| G30/G31 50/50mbar
3B/P
G30/G31 30/30mbar 3B/P|
G30/G31 30/30mbar 3B/P
Countries
| AT,CH| NL| HU| PL|
DE
Efficiency Declaration 2016/426
PVUH60MF – STANDARD (L1)
SINGLE BURNER EFFICIENCY
AUX| SR| SR|
R
–
| 60%| 60%| 54,3%
MEDIUM %58
PVUH60MF – 3 GAS (L2)
SINGLE BURNER EFFICIENCY
AUX| R|
DC 4,5 kW
–
| 56%| 55,8%
MEDIUM %55.9
PVUH60MF – BIG REAR (L3)
SINGLE BURNER EFFICIENCY
AUX| SR| R|
DC 4 kW
–
| 60%| 54,3%| 57,6%
MEDIUM %57.3
PVUH75MF – Central (L4)
SINGLE BURNER EFFICIENCY
AUX| SR| R (Left)| R (Right)|
DC 4,5 kW
–
| 60%| 53%| 55,9%| 56,6%
MEDIUM %56.3
The manufacturer will not be responsible for any inaccuracy resulting from printing or transcript errors contained in this brochure. We reserve the right to carry out modifications to products as required, including the interests of consumption, without prejudice to the characteristics relating to safety or function.