ekomia Levi Height Adjustable Table Frame Instruction Manual

June 17, 2024
ekomia

ekomia logo Levi Height Adjustable Table Frame
Instruction Manual

Levi Height Adjustable Table Frame

ekomia Levi Height Adjustable Table Frameekomia
Levi Height Adjustable Table Frame - iconekomia Levi Height Adjustable Table Frame -
feager

Safety Information

  1. Assembly and operation of the Levi must be in accordance with these assembly instructions otherwise there is a risk of injury!
  2.  The table support is solely intended to serve the purpose of ergonomic adjustments for your desk in accordance with the weights and measurements given in these instructions. Any usage other than that mentioned above is inappropriate; the manufacturer  disclaims liability for any resulting damages. In such cases all risk is carried by the user.
  3. Please also take into account the general legal and other regulations and legal provisions that are applicable including those that apply in the operator‘s country as well as the applicable environmental protection regulations. The regulations of trade  associations or other supervisory authorities that are in force locally must always be observed!
  4. The manufacturer cannot be held responsible for any losses or damage resulting from unauthorized modifications of the Levi. The power supply is to be used exclusively for Kesseböhmer guide columns!
  5. Store the Assembly and Operation Instructions close to the device.
  6. This appliance can be used by children aged from 14 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a  safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not leave children unattended with the table support. Children cannot estimate  the danger of the force that the table support has.
  7. To avoid any danger of jamming or crushing it is necessary to keep a minimum distance of 25mm to the moving parts.
  8. The assembly site should be dry, dust-free and without direct sunlight. Make sure that no liquid enters the column unit or power supply as this could cause electrical shock or short circuit!
  9. The duty cycle of the system is set to 2 minutes “ON” and 18 minutes “OFF” or 0.5 minutes “ON” and 9 minutes “OFF”. Power cables must not be pinched, bent, stretched or mechanically stressed!
  10. The socket for connection with the mains must be installed by a licensed electrician in order to avoid any hazard to persons or objects.
  11. Load limits must not be exceeded.
  12. Never open the housing of the power supply! Danger to the user can arise and the guarantee claim will expire as a result of unauthorized opening of the housing and improper repairs. Only the manufacturer’s service technicians are authorized to open or  repair the electrical equipment!
  13. In the event of a malfunction for example smoke, odors, unusual noises, or visible external damage switch off the system. Disconnect at the mains!

ekomia Levi Height Adjustable Table Frame - feager1

No pre-drilling required, screw directly into the tabletop. Position the frame centred as desired.

ekomia Levi Height Adjustable Table Frame - feager2| ekomia Levi Height Adjustable Table Frame -
feager3
---|---
ekomia Levi Height Adjustable Table Frame - feager4| ekomia Levi Height Adjustable Table Frame -
feager5
ekomia Levi Height Adjustable Table Frame - feager 6| ekomia Levi Height Adjustable Table Frame -
feager7
ekomia Levi Height Adjustable Table Frame - feager8| ekomia Levi Height Adjustable Table Frame -
feager9

ekomia Levi Height Adjustable Table Frame - feager 10ekomia Levi Height Adjustable Table Frame - feager
11

Reset: Crushing and shearing hazard!
When restoring the control system to the factory settings and when resetting, the collision protection ISP [Intelligent System Protection] is inactive.
Make sure that no objects or persons are in the danger zone (safety distance > 25 mm) and that they do not reach into the danger zone.
Initial Startup
When starting up the operating system for the first time, a reset is required. Through the reset, e.g. with a table, all columns are brought to the same level in the middle table position. This ensures that the table top moves parallel to the  ground.
Before using the Levi desk a Position Reset Procedure must be carried out. You do this as follows:
Reset:

  1. Exit the energy-saving mode of the control system by briefly pressing the UP or DOWN button.
  2. Hold down the UP and DOWN buttons at the same time. After approx. 3 seconds, the reset starts. Keep the buttons pressed until reaching the reset position is confirmed by a triple clicking sound from the control system.
  3. Now release the buttons.

ekomia Levi Height Adjustable Table Frame - feager 12

Controller functions

| Move table: Hold button, the table moves up or down.
---|---
1 2 3 4| Preset height: Press and hold the key, the desk will move to the saved position.
M| Menu / Memory: Hold for one second activates the save height function. Hold 3 seconds opens menu, then press briefly confirms functions in menu.
E| Escape: Press this key to return to the menu.
| Save height : Press and hold M until the Save symbol appears. Then press 1, 2, 3 or 4 within 3 seconds. The table confirms the saved position by double-click sound.
| Change the maximum height: Move the table to the wanted position then press M and hold it for 3 seconds. Select the Stop Shelf menu with the  arrow. Confirm with the M key and select on or off with the arrow keys and confirm with M.
| Change maximum depth: Move the table to the wanted position then press M and hold it for 3 seconds. Select the Stop Container menu with the  arrow. Confirm with the M key and select on or off with the arrow keys and confirm with M.
| Change the displayed height: Press M and hold for 3 seconds. Select the Offset menu with the arrow. Confirm with the M key, then set the value  with the arrow keys. Confirm with the M key.
| Change length unit: Press M and hold for 3 seconds. Select the Unit menu with the arrow keys. Confirm with the M key, then set the unit with  the arrow. Confirm with the M key.
| Lock controller: Press M and hold for 3 seconds. Use the arrow to select the Keylock menu. Confirm with the M key and select on or off with the arrow and confirm with M.
| Factory Reset: Press M and hold for 3 seconds. Select the Hard Reset menu with the arrow. Confirm with the M key, then select YES with the  arrow keys and confirm with M. Data Erase? confirm again with the M key and then perform a normal reset.
Reset| Reset:
1. Disconnect the desk from the power supply for 30 seconds, then reconnect it.
2. Press and hold both arrows at the same time. After approx. 3 seconds, the reset will begin. Keep the keys pressed until the table has completely reached the end position and the reset is confirmed by a triple click sound from the control unit.

Chic!

ekomia Levi Height Adjustable Table Frame - feager 13

[email protected]

Error messages on the control display

The display reads HOT

Cause Remedy

The control unit is fitted with overheating protection. Overheating has caused it to stop the control unit.| The control unit is fitted with overheating protection. Overheating has caused it to  stop the control unit.

The display reads E + an error code

Code / Description Behuing

00 Internal Error Channel 1
01 Internal Error Channel 2
02 Internal Error Channel 3| Perform a rest.
12 – 14 Short circuit in the system| Disconnect the motor control unit. Remedy the external short circuit.
Or
Connect the correct motor to the affected socket. Put the motor control unit back
into operation.
24 – 25 – 26 Overcurrent in motor| Replace control
48 – 49 – 62 Table overloaded| Remove load from the table
36 Plug Detection in M1
37 Plug Detection in M2| Plug the correct motor into the affected socket.
55 – 56 Sync of the Columns lost| Remove load from the table. Perform a reset.

60 Collision protection| Remove objects from the driving area
61 -70 -71 -72 – 73 – 81 Changing the Configuration| 1. Unplug the power cord for 30 seconds.
2. Check the control motor cable, the column motor cables and the cascading cables. 3. Perform a reset.
93 Cascading cable damaged or not plugged incorrectly| 1. unplug the power cord.
2. check the cables, especially the cascading cable.
3. perform a reset

*Note: If the problem still exists, perform a factory reset. If the problem still exists, contact customer service.

Additional Information

  1. The Levi adjustable base is designed to carry up to 130 kg in weight. The weight of the top used needs to be included in this.
  2. Intelligent System Protection (ISP) is an electronic state-of-the-art protection system. It also substantially reduces the risk of fingers being trapped or pinched. In spite of ISP being in place, there may still be a risk of pinching in  exceptional cases, as it is not only the control unit, but also the interaction between the mechanical and electronic systems that is responsible for cutting out the motor. In addition, the mechanical components, motor and ambient conditions all affect cut-out sensitivity.

Disposal

Information on the disposal of electrical and electronic equipment in the European Union:
Within the European Union, the disposal of electrically operated equipment is governed by national regulations based on the EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). In accordance with this, the device must no longer be disposed of with municipal waste or household waste. The device is accepted free of charge at municipal collection points or recycling centers. Product packing consists largely of recyclable materials. Dispose of it  in an environmentally friendly manner and bring it in for recycling.

ekomia logo

+49 (0) 30 41 76 19 72
ekomia.de
 [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ekomia User Manuals

Related Manuals