RENOGY RCM-BT1-G1 Bluetooth Module User Manual

June 6, 2024
Renogy

RENOGY logo

BT-1 BLUETOOTH MODULE
Bluetooth Module for Solar Charge Controllers
Version 2.1

RENOGY RCM-BT1-G1 Bluetooth Module -fig7

General Information

The Renogy BT-1 is a great addition to any compatible Renogy solar charge controller. Powered by its RJ12 communication port, the BT-1 provides wireless monitoring of system data and allows users to change parameters through the Renogy DC Home smartphone App.

Key Features

  • Wirelessly monitor and control compatible solar charge controllers via Bluetooth
  • Connects to our user-friendly smartphone App, Renogy DC Home, to keep track of your system
  • Embedded exclusive Bluetooth chip with high efficiency and low energy consumption
  • Bluetooth 4.2 and BLE technology provides fast and uninterrupted communication
  • Powered directly through the RJ12 communication port
  • Signal range up to 82ft(25m)
  • Two LED lights indicate the power and Bluetooth connection condition

Identification of Parts

RENOGY RCM-BT1-G1 Bluetooth Module -fig6

RENOGY RCM-BT1-G1 Bluetooth Module -fig5

To Download App

  1. The Android version of the Renogy DC Home APP is available to download on
    Renogy.com and the Google Play Store.
    In the Google Play Store, simply search “Renogy DC Home” in the App Store to download.

  2. For the IOS version, simply search “Renogy DC Home” in the App Store to download.

Operation

  • Connection
    Connect the BT-1 Bluetooth module to any Renogy solar charge controller with an RJ12 port and RS232 communication protocol.

RENOGY RCM-BT1-G1 Bluetooth Module -fig4

  • Communication status indicator

Green Power Indicator:

Power Indicator|

Status

|

Note

---|---|---
Solid (Green)| Power On
Off| Power Off

Blue Communication Indicator:

Link Indicator|

Status

|

Note

---|---|---
Flashing (Blue)| Communicating
Off| Stand by

  • Compatible Models

Compatible Models

| All Renogy Controllers with RJ12 port
---|---
RNG-CTRL-ADV30
RNG-CTRL-WND10
RNG-CTRL-WND30LI
RNG-CTRL-WNDPG10| RNG-CTRL-RVR20
RNG-CTRL-RVR30
RNG-CTRL-RVR40
RNG-CTRL-RVR60
RNG-CTRL-RVR100

Communication Protocol

|

RS232

Port Type

|

RJ12

How to Connect Via Renogy DC Home App:

  1. First-time users of the Renogy DC Home App will need to create an account. If you have an existing Renogy.com account, you can use those same credentials. Otherwise, you will need to register a new account.
    RENOGY RCM-BT1-G1 Bluetooth Module -fig3

  2. After logging in successfully, you need to add your device. You can do this by clicking the blue plus button located in the upper right corner or by tapping the blue “+Add devices” link at the bottom of the screen.
    RENOGY RCM-BT1-G1 Bluetooth Module -fig2

  3. An Operation Guide will pop up. Follow the directions by turning on your device’s Bluetooth and then selecting “Next”. After confirming your connection, tap the checkbox and then select “Next”. The App will now look for the device.
    RENOGY RCM-BT1-G1 Bluetooth Module -fig1

  4. When a device is found, select the Bluetooth device, then name the device if you wish. Afterward, press “Next” and then select the type of device you are connecting. In this example, we will select Charge Controller. When successful, the App will confirm the product SKU. If the SKU is correct, click“OK” to start communicating with your Rover 30Amp.
    RENOGY RCM-BT1-G1 Bluetooth Module -fig

  5. In the main interface, you can see the general parameters of the charge controller under the “my devices” section.

RENOGY RCM-BT1-G1 Bluetooth Module -moble

Technical Specifications

Description Parameter
Model BT-1
Standby Power Consumption 0.04W
Operating Power Consumption 0.05W
Communication Range ≤82ft (25m )
Serial Baud Rate Fixed Baud Rate 9600bps
Communication Protocol RS232
Port Type RJ12
Cable Length 5.00m (16.4ft)
Dimensions 67.3 X 35 X 14mm

2.65 X 1.38 X 0.55in
Installation Dimensions| 67.3   φ3.5mm (2.66 φ 0.14in )
Operation Temperature| -20 ℃~85 ℃(-4°F to 185°F )
Protection Grade| IP54
Weight| 130g(4.58oz)

FCC Compliance Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
(3)FCC 20cm Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2)This device must accept any interference, including interference that may cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain
Canadian information on RF exposure and compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.

RENOGY logo RENOGY.COM
Renogy reserves the right to change the contents of this manual without notice.

2775 E Philadelphia St, Ontario, CA 91761, USA
909-287-7111
www.renogy.com
 support@renogy.com| https://ca.renogy.com
supportca@renogy.com
---|---
https://au.renogy.com
supportau@renogy.com| https://uk.renogy.com
supportuk@renogy.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Renogy User Manuals

Related Manuals