The RENOGY 1000 Portable Power Station (RPS100150AA-PCS) is a portable power source that can be used to charge and power various electronic devices. It is designed for outdoor activities, emergencies, and power outages, and can be recharged with solar panels or AC power.

Product Before Getting Started

It is important to read the user manual carefully before operating the Portable Power Station. Failure to follow the instructions or precautions in the user manual can result in electrical shock, serious injury, or damage to the product.

Product Features

  • LED display that shows battery level, voltage, and current
  • Multiple charging options: AC power and solar panels
  • Multiple output ports: USB-A, USB-C, CIG, and AC outlets
  • Overload protection, voltage protection, current protection, battery protection, low-temperature protection, and high-temperature protection
  • Operating status ring that indicates charging and discharging status

Product Usage Instructions

  1. Charge the Portable Power Station using either AC power or solar panels. The LED display will show the battery level and charging status.
  2. Connect your electronic device to the desired output port (USB-A, USB-C, CIG, or AC outlets). The LED display will show the voltage and current.
  3. Press the corresponding on/off button to turn on/off the desired output port (USB-A, USB-C, CIG, or AC outlets).
  4. Press the power on/off button to turn on/off the Portable Power Station.
  5. The operating status ring will indicate the charging and discharging status of the Portable Power Station. When all ring segments are on, the Portable Power Station is fully charged. When the ring is rotating counterclockwise, the Portable Power Station is discharging. When one ring segment is flashing slowly, the battery level is less than 10%.

Before Getting Started

The user manual provides important operation and maintenance instructions for RENOGY 1000 Portable Power Station (hereinafter referred to as Portable Power Station).
Read the user manual carefully before operation and save it for future reference. Failure to observe the instructions or precautions in the user manual can result in electrical shock, serious injury, or death, or can damage the portable power station, potentially rendering it inoperable.

  • Renogy ensures the accuracy, sufficiency, and the applicability of information in the user manual at the time of printing due to continual product improvements that may occur.
  • Renogy assumes no responsibility or liability for personal and property losses, whether directly and indirectly, caused by the user’s failure to install and use the product in compliance with the user manual.
  • Renogy is not responsible or liable for failures, damages, or injuries resulting from repair attempted by unqualified personnel, improper installation and operation.
  • The illustrations in the user manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
  • Renogy reserves the right to change the information in the user manual without notice. For the latest user manual, visit renogy.com.

Disclaimer

RENOGY 1000 Portable Power Station User Manual © 2023 Renogy. All rights reserved. RENOGY and renogy are registered trademarks of Renogy.

  • All information in the user manual is subject to copyright and other intellectual property rights of Renogy and its licensors. The user manual may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.
  • The registered trademarks in the user manual are the property of Renogy. The unauthorized use of the trademarks is strictly prohibited.

Online Manual

DC Home App

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-2

Symbols Used

The following symbols are used throughout the user manual to highlight important information.

  • WARNING: Indicates a potentially dangerous condition which could result in injury or death.
  • CAUTION: Indicates a critical procedure for safe and proper installation and operation.
  • NOTE: Indicates an important step or tip for optimal performance.

What’s In the Box?

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-3

  • Make sure that all accessories are complete and free of any signs of damage.

Optional Accessories

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-4

  • The optional accessories are available on renogy.com.

Get to Know RENOGY 1000 Portable Power Station

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-5

LCD Display

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-6

  • Pay attention if the [High-Temperature Protection], [Low-Temperature Protection], [Battery Protection], [Current Protection], or [Voltage Protection] icon appears. Please refer to the “Troubleshooting” section for detailed instructions.
  • When no operation is made for 5 minutes, the LCD Display will go out automatically to save energy. Short press the Power On/Off Button to light up the LCD Display.

Environmental Conditions

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-7

Turning On/Off

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-8

Communication with DC Home

Bluetooth Connection

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-9

How to Customize Parameters

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-10

  • The portable power station only connects to the 2.4GHz Wi-Fi network.

How to Charge by Solar Panels

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-11

How to Charge by AC Power

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-12

  • The iTurbo technology enables the portable power station to be charged up to 80% within 1 hour. When the charging current exceeds the current rating of the AC Inlet, the Overload Protector will pop up automatically and the AC charging stops. Please disconnect the AC power cable first and press down the Overload Protector to reset it. Contact us for help if the Overload Protector pops up again: renogy.com/contact-us/.RENOGY-RPS100150AA-PCS-Portable-Power-Station-1000-FIG-13

How to Charge by Car

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-14

How to Power Your Devices

The portable power station can provide a total output power of up to 2100W. When the portable power station is overloaded, it will turn off the USB-A Ports, USB-A Fast Charge Port, and USB-C Ports, CIG Port, and AC Outlets in sequence until the total output power drops below 2100W.

  • The portable power station might not be able to deliver exact 998.4Wh energy when powering high-power devices.

USB-A/USB-C Devices

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-15

  • When both the USB-C Ports are in use, each USB-C Port can only deliver up to 60W output power.
  • To get up to 18W output power from the USB-A Fast Charge Port, the USB-A device must support the Quick Charge (QC) standard.
  • To get up to 100W output power from the USB-C Input/Output Port, the USB-C device must support the Power Delivery (PD) standard.
  • When the device draws low or no power from the USB-A Ports, USB-A Fast Charge Port, and USB-C Ports for 1 hour, the USB-A Ports, USB-A Fast Charge Port, and
  • USB-C Ports will turn off automatically to save energy.

Car-Powered Devices via CIG

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-16

  • When the device draws low or no power from the CIG Port for 1 hour, the CIG Port will turn off automatically to save energy.

AC Devices
The iBoost mode allows the AC Outlets to power most resistive AC devices rated between 1500W and 3000W, The iBoost mode is enabled by default. The iBoost mode is not applicable for the inductive and capacitive AC devices with strict voltage limits.RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-17

  • Please select the output frequency of the portable power station in accordance with the AC device specifications.
  • The portable power station might not be able to power the AC devices that require high starting currents even though they are rated under 1500W.
  • When the device draws low or no power from the AC Outlets for 1 hour, the AC Outlets will turn off automatically to save energy.

Automatic Power-Off

When the Portable Power Station is not being charged and the USB-A Ports, USB-A Fast Charge Port, USB-C Ports, CIG Port, and AC Outlets are off for 1 hour, the portable power station will turn off automatically to save energy.

Standby Power Supply (SPS)

The portable power station can work as a SPS to deliver emergency AC power to devices during a power outage.RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-18

  • DO NOT connect AC devices that require a transfer time less than 20ms (such as data servers and workstations) to the portable power station for uninterrupted AC power. Please check the holdup time of the power supply units (PSU) in the AC devices to confirm compatibility.
  • The iBoost mode will be automatically disabled when the SPS mode is turned on.

Parallel Connection

The iStack technology allows two RENOGY 1000 portable power stations to be connected in parallel to deliver 1996.8Wh capacity and 2700W AC output .RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-19

  • Please ensure that the AC Outlets of the two portable power stations have the same output voltage and output frequency.
  • Please ensure that the two RENOGY 1000 portable power stations have AC Outlets turned on.
  • The AC Inlet will be disabled with AC charging and SPS mode off when the single-phase parallel kit is connected to the portable power station.
  • The AC Outlets will be turned off temporarily when connecting the two portable power stations in parallel.

Strip Lights Operation

  • When the LED Strip Lights are on, short press the Light On/Off Button to switch the lighting modes, and the LED Strip Lights light off. The LED Strip Lights offer three lighting modes – solid, breath, and flow.
  • When the portable power station is being charged, the LED Strip Lights will automatically turn on in breath mode by default.

Troubleshooting

If the portable power station does not operate properly, refer to the table below for possible causes and corrective steps. If the corrective steps do not work, contact our customer service through renogy.com/contact- us/.

RENOGY-RPS100150AA-PCS-Portable-Power-
Station-1000-FIG-21 RENOGY-RPS100150AA-
PCS-Portable-Power-Station-1000-FIG-22

Specifications

General

Dimension 18.27 x 10.79 x 11.57 inch / 464 x 274 x 294 mm
Weight 41.0 lbs / 18.6 kg
Charge Temperature 32°F~104°F / 0°C~40°C (Recommended) 32°F~131°F /

0°C~55°C (Extreme)
Discharge Temperature| -4°F~104°F / -20°C~40°C (Recommended)

-4°F~131°F / -20°C~55°C (Extreme)

Storage Temperature| -4°F~95°F / -20°C~35°C

Battery

Type Lithium Iron Phosphate
Capacity 41.6V, 24000mAh / 998.4Wh
Cycle Life 3000 Cycles (80% DOD, 80% EOL)

Input

AC Input| 85V~120V (JP)/90V~140V (US & CA)/200V~240V (EU, UK, AU, KR & CN)

About 45Hz~55Hz/57Hz~65Hz, 998W Max

---|---
DC Input| 10V~100V 10A, 400W Max

Output

USB-A Output (x2) 5V    2.4A, 12W Max
USB-A Fast Charge Output (x1) 5V 3A, 9V 2A, 12V 1.5A, 18W Max
USB-C Output (x2) 5V 3A, 9V 3A, 12V 3A, 15V 3A, 20V 5A, 100W Max
CIG Output (x1) 13.6V    10A, 136W Max
--- ---
AC Output (x3/x6) 100V (JP)/120V (US & CA)/220V~240V (EU, UK, AU, KR &

CN)

About 50Hz/60Hz, 1500W Rated, 3000W Surge

Total Output| 2100W Max

Maintenance & Storage

Inspection
For optimum performance, it is recommended to perform these tasks regularly.

  • Check the appearance of the portable power station to make sure it is clean and dry.
  • Ensure the portable power station is used or stored in a clean, dry, and ventilated area.
  • Make sure that the LCD Display is in normal state.
  • Ensure there is no corrosion, insulation damage, or discoloration marks of overheating or burning.
  • Risk of electric shock! Make sure that all power is turned off before touching the terminals on the portable power station.
  • The portable power station may release toxic gases when burning. Be sure to wear a gas mask when approaching. Put out the fire with a FM-200 or CO2 fire extinguisher. If pungent gases are inhaled, leave the contaminated area immediately and seek medical attention.

Cleaning
Follow the steps below to clean the portable power station regularly.

  • Remove all the connections from the portable power station and turn off the portable power station.
  • Clean the casing of the portable power station with a soft dry cloth.
  • Turn the portable power station back on and reconnect the devices to the portable power station.

Storage

  • Charge the portable power station to 50%.
  • Remove all the connections from the portable power station and turn off the portable power station.
  • Store the portable power station in a well-ventilated, dry, clean area with temperatures between -4°F (-20°C) and 95°F (35°C) and humidity between 10% and 90%.
  • For long-term storage, discharge the portable power station to 30% and charge it to 50% every 6 months.
    • Fully charge the portable power station when it is taken out of storage. Handle the portable power station carefully to avoid sharp impacts or extreme pressure on the casing of the

Important Safety Instructions

General Safety Information

  • Keep the portable power station out of the reach of children.
  • Do not dispose of the portable power station as household waste. Comply with local, state, and federal laws and regulations and use recycling channels as required.
  • In the event of fire, use fire extinguishers suitable for electrical equipment. Acceptable fire extinguishers include an FM-200 or CO2 fire extinguisher.
  • Do not expose the portable power station to flammable or harsh chemicals or vapors.

Portable Power Station Safety

  • Do not puncture, drop, crush, penetrate, shake, strike, or step on the portable power station.
  • Do not open, dismantle, repair, tamper with, or modify the portable power station.
  • Do not insert foreign objects into the portable power station.
  • Do not immerse the portable power station in water or leave it out in the rain.
  • Do not expose the portable power station to direct flame.
  • Keep the portable power station away from flammable or combustible materials.
  • Keep the portable power station away from heating equipment.
  • Ensure that there is no water source including downspouts, sprinklers, or faucets above or near the portable power station.
  • Ensure that snow does not accumulate around the portable power station.
  • Risk of explosion! When being charged, the portable power station may give off noxious or explosive gas. Make sure there is good ventilation.
  • Do not expose the portable power station to strong electrostatic fields, strong magnetic fields, or radiation.
  • Do not lean on, stack anything on top of, or hang anything from the portable power station or from cables leading to the portable power station.
  • Do not touch the exposed electrolyte or powder if the portable power station is damaged.
  • Please inspect the portable power station before each use. Stop using the portable power station if any visible damages including cracks, dents, and deformation or abnormalities including unusual smells and heating are observed.

Charging Safety

  • Only use Renogy-approved accessories to charge the portable power station.
  • Do not use damaged accessories to charge the portable power station as it might cause electric shock.
  • Do not charge the portable power station immediately after a long heavy run.
  • The portable power station turns on automatically once it detects the charging source(s).
  • To prevent car battery overdischarge, charge the portable power station while the car enginer is started.
  • Do not charge the portable power station at high temperatures above 131°F (55°C) or low temperatures below 32°F (0°C). The recommended charge temperature range is between 32°F (0°C) and 104°F (40°C).

Discharging Safety

  • Please charge the portable power station immediately when the battery level drops below 10% to prevent overdischarge.
  • Do not discharge the portable power station at high temperatures above 131°F (55°C) or low temperatures below
    • 4°F (-20°C). The recommended discharge temperature range is between -4°F (-20°C) and 104°F (40°C).
  • To extend the cycle life, please fully charge the portable power station before each use.
  • Do not use the portable power station with life support equipment or other medical equipment.

Solar Charging Safety

  • Do not use damaged solar panels.
  • Place a solar panel (sold separately) under direct sunlight. Steer clear of objects that can shade the solar panel and slow down the charging process.
  • For optimal charging performance, it is recommended to charge the portable power station with the solar panel array on bright sunny days free of clouds.

Renogy Support

To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at:

For technical questions about your product in the U.S., contact the Renogy technical support team through:

For technical support outside the U.S., visit the local website below:

Warranty

Check out the warranty policies for the product from your local Renogy website. For customers in the U.S., register your product and get your e-warranty at https://renogy.force.com/helpcenter/s/warrantyregister.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2ANPB-RPS100150AA

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Orient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Renogy Empowered

Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable energy solutions. We intend to be a driving force for sustainable living and energy independence. In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power.

Live Sustainably with Renogy

Did you know? In a given month, a 1KW solar energy system will…

  • Save 170 pounds of coal from being burned
  • Save 300 pounds of CO⁄ from being released into the atmosphere
  • Save 105 gallons of water from being consumed

Renogy Power PLUS
Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.

  • @Renogy Solar
  • @renogyo‘icial
  • @Renogy

Renogy reserves the right to change the contents of this manual without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Renogy User Manuals

Related Manuals