RENOGY E.FLEX 80-120-220 Portable Solar Panel User Manual
- June 3, 2024
- Renogy
Table of Contents
RENOGY E.FLEX 80-120-220 Portable Solar Panel
APPLICABILITY
The User Manual applies to the following products:
- E.FLEX 80 Portable Solar Panel (RSP80EF)
- E.FLEX 120 Portable Solar Panel (RSP120EF)
- E.FLEX 220 Portable Solar Panel (RSP220EF)
DISCLAIMER
- Renogy makes no warranty as to the accuracy, sufficiency, or suitability of the information in the User Manual because continuous product improvements are going to be made.
- Renogy assumes no responsibility or liability for losses or damages, whether direct, indirect, consequential, or incidental, which might arise out of the use of information in the User Manual.
- Renogy is not responsible or liable for the failures, damages, or injuries resulting from repair attempted by unqualified personnel or improper installation and operation.
- The illustrations in the User Manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
- Renogy reserves the right to change the information in the User Manual without notice.
COPYRIGHT
E.FLEX Series Portable Solar Panel User Manual © 2022 Renogy. All rights
reserved. All information in the User Manual is subject to copyright and other
intellectual property rights of Renogy and its licensors. The User Manual may
not be modified, reproduced, or copied, in whole or in part, without the prior
written permissions of Renogy and its licensors.
TRADEMARKS
The following are trademarks or registered trademarks of Renogy in the
United States and other countries:
All other trademarks in the User Manual are the property of their respective owners and their use herein does not imply sponsorship or endorsement of their products or services. The unauthorized use of any trademark displayed in the User Manual or on the product is strictly prohibited.
Important Safety Instructions
Please save these instructions.
The User Manual provides important operation and maintenance instructions for
E.FLEX Series Portable Solar Panel. Please read the User Manual carefully
before operation and save it for future reference. Failure to observe the
instructions or precautions in the User Manual can result in electrical shock,
serious injury, or death, or can damage E.FLEX, potentially rendering it
inoperable.
Symbols Used
The following symbols are used throughout the User Manual to highlight
important information.
- Indicates a potentially dangerous condition that could result in injury or death.
- Indicates a critical procedure for safe and proper installation and operation.
- Indicates an important step or tip for optimal performance.
General Safety Information
- DO NOT disassemble the unit or remove any attached components.
- DO NOT puncture, drop, crush, penetrate, shake, strike, or step on E.FLEX.
- DO NOT open, dismantle, repair, tamper with, or modify E.FLEX.
- DO NOT place the unit on a surface constructed from combustible material.
- DO NOT expose E.FLEX to direct flame or heat sources.
- Please keep the unit out of reach of children unless supervised by an adult.
- Please keep the unit away from explosives and corrosive substance
- DO NOT step, walk, stands or jump on the unit. Localized heavy loads may cause damage to the solar cell, which will ultimately compromise the performance of the unit
- DO NOT band the unit, or the panel will be broken
- DO NOT immerse the unit in water.
- Dispose of the unit according to the local recycling and environmental regulations
Package Contents
- 1 x Renogy E.FLEX Portable Solar Panel
- 1 x Case
- 1 x User Manual
Specifications
Model: E.FLEX 80 (RSP80EF)
Dimensions (fold) | 24.8 x 17.1 x 1.0 in / 631 x 435 x 25 mm |
---|---|
Dimensions (unfold) | 24.8 x 34.2 x 0.2 in / 631 x 870 x 4 mm |
Weight | 7.3 lbs. / 3.3 kg (Approximately) |
Operation Temperature | -4°F to 149°F / -20°C to 65°C |
Max Power at STC | 80W |
Open-Circuit Voltage | 20.7 V |
Short-Circuit Current | 4.9 A |
Optimum Operating Voltage | 17.2 V |
Optimum Operating Current | 4.7 A |
Cell Type | Monocrystalline Silicon |
Connector | MC4 |
Dimensions (fold) | 26.4 x 21.7 x 1.0 in / 671 x 551 x 25 mm |
--- | --- |
Dimensions (unfold) | 26.4 x 43.5 x 0.2 in / 671 x 1102 x 4 mm |
Weight | 11.0 lbs. / 4.8 kg (Approximately) |
Operation Temperature | -4°F to 149°F / -20°C to 65°C |
Max Power at STC | 120W |
Open-Circuit Voltage | 23.8 V |
Short-Circuit Current | 6.4 A |
Optimum Operating Voltage | 19.8 V |
Optimum Operating Current | 6.1 A |
Cell Type | Monocrystalline Silicon |
Connector | MC4 |
Dimensions (fold) | 29.1 x 22.9x 1.6 inch / 738 x 581 x 40 mm |
--- | --- |
Dimensions (unfold) | 29.1 x 84.1 x 0.2 inch / 738 x 2135 x 4 mm |
Weight | 20.4 lbs. / 9.23 kg (Approximately) |
Operation Temperature | -4°F to 149°F / -20°C to 65°C |
Max Power at STC | 220W |
Open-Circuit Voltage | 26.8 V |
Short-Circuit Current | 10.2 A |
Optimum Operating Voltage | 22.7 V |
Optimum Operating Current | 9.1 A |
Cell Type | Monocrystalline Silicon |
Connector | MC4 |
Operation
How to charge a power station
- Place a solar panel under direct sunlight. Steer clear of objects that can shade the solar panel and slow down the charging process.
- Connect the solar connectors of the solar panel with the solar charge cable (sold separately), then Connect the DC input port of the power station.
- The solar charge time is highly dependent on solar irradiance and ambient temperature.
- The operating voltage of the solar panel shall exceed the minimum DC-input voltage of the power station, and the open circuit voltage shall NOT exceed the maximum DC-input voltage of the power station.
How to charge the battery
- Connect E.FLEX connector to PV Terminals of charge controller (sold separately).
- Connect the BATT Terminals of the charge controller to battery terminals using tray cables (sold separately)
- Set the charging parameter on the charge controller, and the E.FLEX is ready to charge the battery.
How to connect E.FLEX in series/parallel
- To expand the power output, E.FLEX can be connected either in series or parallel.
- Connect E.FLEX in series.
- Connect E.FLEX in parallel.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
RENOGY.COM Renogy reserves the right to change the contents of this manual without notice.
Archibald Ave, Ontario, CA 91762
909-287-7111
www.renogy.com
support@renogy.com
References
- Renogy® Official- offer all off grid solar system products
- Renogy® Official- offer all off grid solar system products
- Solar Power Kits & Equipment for Sale | Renogy Australia
- Renogy® Canada solar off-grid items, Canadian solar panels
- Renogy bietet alle Produkte für netzunabhängige Solarsysteme anRenogy DE
- Top off-grid solar kits, lithium batteries supplies | Renogy UK
- RENOGY如果新能源 | 让每个人拥有独立清洁的能源