Sunco Lighting VT Series LED Selectable Vapor Tight Fixture User Manual

August 27, 2024
Sunco Lighting

VT_DU-WH-3550K
VT2_25SW-GR-3550K
VT8_90SW-GR-3550K
User Manual
LED Selectable Vapor
Tight Fixture

What’s in the Box?

Before You Start

Safety Information
To reduce the risk of fire, electric shock, or physical injury:

  • Turn off power before changing fixture.
  • Suitable for use in damp environments at temperatures ranging from 40°F to 122°F. Not for use where directly exposed to water.
  • Not intended for use with emergency fixtures.
  • Not compatible with photo controls.
  • Not compatible with occupancy sensors.
  • Not compatible with 3rd party sensors.
  • Not compatible with timing devices.
  • Not compatible with all dimmers. For more dimming information, please visit www.sunco.com.
  • All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards.
  • Please review installation manual carefully before  proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.
    WARNING:
    Cancer & Reproductive Harm- www.P65Warnings.ca.gov

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

Product size

Installation Guide (Surface Mount)

STEP 1
a. Turn off circuit breaker. STEP 2
a. Locate area to hang light fixture, then position to on ceiling.
b. Determine proper spacing for vapor tight size (approximate):
• 2FT: 10.5 – 16.25” apart
• 4FT: 30 – 35.75” apart
• 8FT: 75.25 – 80.75” apart
c. Mark each side, drill pilot hole to marked areas, then insert plastic anchors (C).

STEP 3
a. Attach mounting brackets (B) to the ceiling surface with mounting screws (D) and gaskets (E + F).
b. Screw mounting screws (D) until mounting bracket is firmly in place. STEP 4
Press fixture housing to the mounting brackets (B) until both sides of the housing recesses are secured. STEP 5
a. Release latches by pulling metal latches away from housing.
b. Select desired wattage (1) and CCT (2) using the switches inside fixture. STEP 6
a. Install waterproof cable gland (G) on opening of fixture, feed supply wires through it, then connect wires together:

  • Black to Black (Live)

  • White to White (Live)

  • Green to Bare Copper (Ground).
    b. Optional: To use dimming features, connect dimming wires together:

  • Pink to Pink • Purple to Purple

STEP 7
a. Reattach LED tray and lens back to the fixture.
b. Secure lens to housing with lens latches.
c. Turn on circuit breaker and test light.
Installation Guide (Hanging Mount) STEP 1
a. Turn off circuit breaker. STEP 2
a. Locate area to hang light fixture, then position to on ceiling.
b. Determine proper spacing for vapor tight size (approximate):
• 2FT: 10.5 – 16.25” apart
• 4FT: 30 – 35.75” apart
• 8FT: 75.25 – 80.75” apart
c. Mark each side, drill pilot hole to marked areas, then insert plastic anchors (C). STEP 3
a. Attach V-Hooks (A) to each mounting bracket (B) by spreading ends of V-Hooks (A), then insert legs nto holes of mounting bracket (B).
b. Press fixture housing to mounting brackets (B) until both sides of housing recesses are secured.
c. Hang fixture from ceiling with hanging equipment (not included) using V-Hooks installed on mounting brackets (B). STEP 4
a. Release latches by pulling metal latches away from housing.
b. Select desired wattage (1) and CCT (2) using the switches inside fixture. STEP 5
a. Install waterproof cable gland (G) on opening of fixture, feed supply wires through it, then connect wires together:
• Black to Black (Live) • White to White (Live)
• Green to Bare Copper (Ground).
b. Optional: To use dimming features, connect dimming wires together:
• Pink to Pink • Purple to Purple STEP 6
a. Reattach LED tray and lens back to the fixture.
b. Secure lens to housing with lens latches.
c. Turn on circuit breaker and test light.

Product Details

Recommended Dimmers

Brand Model
LUTRON DIVADVSTV
LUTRON Maestro MS-Z101
LUTRON Nova T NTSTV
LEVITON Sunrise SR1200ZTUNV
PHILIPS ILLUMATECH IP710-LFZ

Scan for the full compatible dimmer list!

https://qrco.de/beLmyG

VT_DU-WH-3550K Specifications

Voltage 120V-277V
Wattage 38W/46W/54W
Power Factor >0.9
Beam Angle 110°
Efficacy 130 lm/w
Housing Material PC+Steel
Dimmable 0-10V
Average Lifetime 50,000 hrs
Lumens 5000/6000/7000lm
Moisture Rating Wet
CRI 80
Usage Indoor
Amps 0.45A
Warranty 7 Years

VT2_25SW-GR-3550K Specifications

Voltage 120V-277V
Wattage 15W/20W/25W
Power Factor >0.9
Beam Angle 110°
Efficacy 130 lm/w
Housing Material PC+Steel
Dimmable 0-10V
Average Lifetime 50,000 hrs
Lumens 1950/2600/3250lm
Moisture Rating Wet
CRI 80
Usage Indoor
Amps 0.21A
Warranty 7 Years

VT8_90SW-GR-3550K Specifications

Voltage 120V-277V
Wattage 16W/75W/90W
Power Factor >0.9
Beam Angle 110°
Efficacy 130 lm/w
Housing Material Polycarbonate
Dimmable 0-10V
Average Lifetime 50,000 hrs
Lumens 8450/9750/11700lm
Moisture Rating Wet
CRI 80
Usage Indoor
Amps 0.19-0.75A
Warranty 7 Years

Common Troubleshooting

We’ve got you covered! Our troubleshooting section is here to shed some light and provide you with easy-to-follow solutions for any problem.
If you still need some assistance, feel free to contact us. Our team of lighting experts are happy to help brighten your day.

Installation
Light isn’t turning on.| Double check if fixture is properly connected and circuit breaker hasn’t been tripped.
---|---
Light isn’t bright enough.| Check proper wattage & for unobstructed fixture.
Dimming
Light not dimming to lowest setting.| Ensure minimum dimmer load requirement is met.
Light not dimming smoothly.| Verify dimmer compatibility with fixture.
Light not compatible with dimmer switch.| Check light-dimmer compatibility. Consider purchasing compatible switch if necessary.
Flickering
Light is flickering when turning on.| Verify dimmer switch compatibility.
Light flickering with lights on the same circuit.| Verify fixture compatibility and that it is grounded.
Light flickering when turned on.| Check that fixture wiring connections are secure.
Light flickering when dimmed.| Prevent circuit overload from lights.
Buzzing
Fixture buzzing with power outages.| Confirm secure surge protector link for light.
Fixture buzzing with appliances.| Look for nearby interferences that can cause buzzing. Such as televisions, radios, etc.
Fixture buzzing when dimmed.| Verify dimmer switch compatibility.

Light Distribution Angle

VT_DU-WH-3550K&VT8_90SW-GR-3550K
Not a lighting nerd?
No worries, you can skip this page AVERAGE BEAM ANGLE (50%): 110.8 DEG

| C0/180| 120.0°
---|---|---
| C90/270| 101.6°

UNIT: cd Luminous Intensity Distribution 1
VT2_25SW-GR-3550K Not a lighting nerd?
No worries, you can skip this page
AVERAGE BEAM ANGLE (50%): 107.3 DEG

| C0/180| 115.8°
---|---|---
| C90/270| 98.9°

UNIT:cd Luminous Intensity Distribution 1
The lighting distribution angle determines how light spreads from a source and impacts its illumination.
Two main types exist:
symmetric and asymmetric.
Symmetric Lighting: This emits light evenly in all directions, forming a cone- shaped pattern. Great for general lighting in large areas, it’s used for tasks like area illumination, security, and perimeter lighting. Also applied in up- lighting.
Asymmetric Lighting (Beam Angle): This directs light in a specific direction, reducin glare and spill. Ideal for task lighting, it’s common in settings like landscapes, retail stores, and museums. ote: Reflectors, lenses, and source to surface distance can affect the lighting distribution angle.

support@sunco.com
844-334-9938

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Sunco Lighting User Manuals

Related Manuals