RENOGY PHOENIX 200 B09WR8C6VB 222Wh Portable Power Station User Manual
- June 3, 2024
- Renogy
Table of Contents
PHOENIX 200 B09WR8C6VB 222Wh Portable Power Station
User Manual
PHOENIX 200
Portable Power Station
Version A0
PHOENIX 200 B09WR8C6VB 222Wh Portable Power Station
APPLICABILITY
The User Manual applies to the following product:
- PHOENIX 200 Portable Power Station (RPS2220AA)
DISCLAIMER
- Renogy makes no warranty as to the accuracy, sufficiency, or suitability of information in the User Manual because continuous product improvements are going to be made.
- Renogy assumes no responsibility or liability for losses or damages, whether direct, indirect, consequential, or incidental, which might arise out of the use of information in the User Manual.
- Renogy is not responsible or liable for the failures, damages, or injuries resulting from repair attempted by unqualified personnel or improper installation and operation.
- The illustrations in the User Manual are for demonstration purposes only. Details may appear slightly different depending on product revision and market region.
- Renogy reserves the right to change the information in the User Manual without notice.
COPYRIGHT
- PHOENIX 200 Portable Power Station User Manual © 2022 Renogy. All rights reserved. · All information in the User Manual is subject to copyright and other intellectual property rights of Renogy and its licensors. The User Manual may not be modified, reproduced, or copied, in whole or in part, without the prior written permissions of Renogy and its licensors.
TRADEMARKS
The following are trademarks or registered trademarks of Renogy in the United
States and other countries:
RENOGY
All other trademarks in the User Manual are the property of their respective
owners and their use herein does not imply sponsorship or endorsement of their
products or services. The unauthorized use of any trademark displayed in the
User Manual or on the product is strictly prohibited.
Important Safety Instructions
Please save these instructions.
The User Manual provides important operation and maintenance instructions for
PHOENIX 200 Portable Power Station. Please read the User Manual carefully
before operation and save it for future reference. Failure to observe the
instructions or precautions in the User Manual can result in electrical shock,
serious injury, or death, or can damage PHOENIX, potentially rendering it
inoperable.
Symbols
Used The following symbols are used throughout the User Manual to highlight
important information.
WARNING Indicates a potentially dangerous condition which could result in
injury or death.
CAUTION Indicates a critical procedure for safe and proper installation
and operation.
NOTE Indicates an important step or tip for optimal performance.
General Safety Information
WARNING
- DO NOT immerse PHOENIX in water or leave it out in the rain.
- DO NOT puncture, drop, crush, penetrate, shake, strike, or step on PHOENIX.
- DO NOT open, dismantle, repair, tamper with, or modify PHOENIX.
- DO NO insert foreign objects into the casing or outlets of PHOENIX.
- Please remove all connections and turn PHOENIX off before cleaning it.
- DO NOT expose PHOENIX to direct flame.
- Please keep PHOENIX away from flammable or combustible materials.
- Please keep PHOENIX away from heating equipment
- DO NOT touch the exposed electrolyte or powder if PHOENIX is damaged.
- DO NOT use PHOENIX with life support equipment or other medical equipment.
- DO NOT touch the exposed electrolyte or powder if PHOENIX is damaged.
- DO NOT use PHOENIX with life support equipment or other medical equipment.
- Please keep PHOENIX out of the reach of young children.
- DO NOT dispose of PHOENIX as household waste. Please recycle PHOENIX in accordance with local, state, and federal regulations.
CAUTION
- Please inspect PHOENIX before each use. Stop using PHOENIX if any visible damages including cracks, dents, and deformation or abnormalities including unusual smells and heating are observed.
- Please use PHOENIX in accordance with its input and output specifications.
- DO NOT expose PHOENIX to flammable or harsh chemicals or vapors.
- DO NOT expose PHOENIX to strong electrostatic fields, strong magnetic fields, or radiation.
- Please ensure that no water sources including downspouts, sprinklers, or faucets are above or near PHOENIX.
- Please ensure that snow does not accumulate around PHOENIX.
- DO NOT lean on, stack anything on top of, or hang anything from PHOENIX or from cables leading to PHOENIX.
- Please ensure that PHOENIX is securely fastened during transportation.
Product Overview
Identification of Parts
- LCD Display
- Power On/Off Button
- AC On/Off Button
- CIG On/Off Button
- DC Input Port
- USB-C Input/Output Port
- CIG Port
- USB-A Fast Charge Ports
- AC Outlet(s)
Package Content
LCD Display
Icon| Name|
Description
---|---|---
| Battery Level| Indicates the current battery level. As the PHOENIX charges,
the ring will light up clockwise with the increasing percentage, and the
endmost ring segment will fast flash. Once PHOENIX is fully charged, all the
ring segments will light up and remain solid. As the PHOENIX discharges, the
ring will go out counter- clockwise. When the battery level drops below 10%,
the last ring segment will slow flash.
| Input Power| Indicates the amount of power going into PHOENIX.
| Output Power| Indicates the amount of power going out of PHOENIX.
| Remaining Time| Indicates the amount of time before PHOENIX is completely
charged or discharged. When PHOENIX idles, the remaining time will show 99
hours.
| AC Outlet Status| Indicates the on/off status and output frequency of the AC
Outlet(s).
| USB-C Port Status| Indicates the usage status of the USB-C Port.
| USB-A Port Status| Indicates the usage status of the USB-A Fast Charge
Ports.
| CIG Port Status| Indicates the on/off status of the CIG Port.
---|---|---
| High Temperature Protection| Indicates the protection related to high
temperatures.
| Low Temperature Protection| Indicates the protection related to low
temperatures.
| Battery Protection| Indicates the protection related to the internal
battery.
| Current Protection| Indicates the protection related to current.
| Voltage Protection| Indicates the protection related to voltage.
CAUTION
· PHOENIX might need special attention if the [High Temperature Protection],
[Low Temperature tection], [Battery Protection], [Current Protection], or
[Voltage Protection] icon appears. Please refer to the Troubleshooting section
for detailed instructions.
Operation
Turning On/Off
- Short press the Power On/Off Button to turn on PHOENIX. The LCD Display will light up to display the operating status of PHOENIX.
- Long press the Power On/Off Button for 3 seconds to turn off PHOENIX. The LCD Display will go out.
Charging
WARNING
- DO NOT charge PHOENIX at high temperatures above 131°F (55°C) or low temperatures below 32°F (0°C). The recommended charge temperature range is between 32°F (0°C) and 104°F (40°C).
- DO NOT use damaged accessories to charge PHOENIX as it might cause electric shock.
CAUTION
- ONLY use Renogy approved accessories to charge PHOENIX.
- DO NOT charge PHOENIX immediately after a long heavy run.
- Please charge PHOENIX immediately when the battery level drops below 10% to prevent overdischarge.
NOTE
- To extent the cycle life, please fully charge PHOENIX before each use.
- It is not required to turn on PHOENIX manually before charging. PHOENIX turns on automatically once it detects the charging source(s).
PHOENIX features 4 charging methods solar, AC, car, and USB-C. AC charging and USB-C charging can be combined for a faster charging speed. Solar Charging
- Place a solar panel (sold separately) under direct sunlight. Steer clear of objects that can shade the solar panel and slow down the charging process.
- Connect the DC Input Port of PHOENIX to the solar connectors of the solar panel with a solar charge cable (sold separately). PHOENIX will start charging automatically.
CAUTION
- The operating voltage of the solar panel shall exceed 10V, and the open circuit voltage shall NOT exceed 25V.
- DO NOT connect multiple solar panels in series.
NOTE
- PHOENIX automatically limits the input power. It is allowed and recommended to charge PHOENIX with a solar panel rated above 60W to account for the energy conversion loss.
- For optimal charging performance, it is recommended to charge PHOENIX with the solar panel on bright sunny days free of clouds.
- The solar charge time is highly dependent on the solar irradiance and the ambient temperature.
AC Charging
- Plug the included AC Power Cable into the included AC Adapter.
- Connect the DC Input Port of PHOENIX to a wall outlet with the AC Power Cable and AC Adapter. PHOENIX will start charging automatically.
Car Charging
- Start the car engine. · Connect the DC Input Port of PHOENIX to the CIG port in the car with the included Car Charge Cable. PHOENIX will start charging automatically.
- Please ensure that the car battery is 12V. The 24V car battery might damage PHOENIX.
USB-C Charging
- Plug a USB-C cable (not included) into a USB-C charger (not included). · Connect the USB-C Input/Output Port of PHOENIX to a wall outlet with the USB-C cable and USB-C charger. PHOENIX will start charging automatically.
NOTE
- For optimal charging performance, it is recommended to charge PHOENIX with a high power USB-C charger that supports the Power Delivery (PD) standard.
Powering Devices
WARNING
- DO NOT discharge PHOENIX at high temperatures above 140°F (60°C) or low temperatures below -4°F (-20°C). The recommended discharge temperature range is between 23°F (-5°C) and 113°F (45°C).
CAUTION
- PHOENIX can provide a total output power of up to 278W. Please allocate the output power rationally. DO NOT overload PHOENIX.
DO NOT connect high power devices to PHOENIX when it is running low.
NOTE
- It is required to turn on PHOENIX manually before powering devices. ·
- When the PHOENIX is overloaded, it will reduce the output power of the USB-C Input/Output Port and turn off the USB-C Input/Output Port, USB-A Fast Charge Ports, CIG Port and AC Outlets in sequence until the total output power drops below 278W.
- PHOENIX might not be able to deliver exact 222Wh energy when powering high power devices
PHOENIX provides 4 kinds of output ports for the devices USB-A fast charge, USB-C, CIG, and AC.
USB-A/USB-C Devices
- Connect the device(s) directly to the USB-A Fast Charge Ports or USB-C Input/Output Port with PHOENIX on. The USB-A Fast Charge Ports or USB-C Input/Output Port will automatically turn on to power the device.
- Disconnect the device(s) from the USB-A Fast Charge Ports or USB-C Input/Output Port. The USB-A Fast Charge Ports or USB-C Input/Output Port will turn off automatically.
- The USB-A Fast Charge Ports can power most USB-A devices including smart watch, electronic book, smartphone, tablet, action camera, digital camera, Bluetooth speaker, wireless headphone, and drone.
- The USB-C Input/Output Port can power most USB-C devices including smartphone, tablet, laptop, handheld game console and DSLR camera.
NOTE
- When both the USB-A Fast Charge Ports are in use, the fast charge function will be disabled.
- To get up to 18W output power from the USB-A Fast Charge Port, the connected device must support the Quick Charge (QC) standard.
- To get up to 60W output power from the USB-C Input/Output Port, the connected device must support the Power Delivery (PD) standard.
Car Powered Devices
- Short press the CIG On/Off Button with PHOENIX on to turn on the CIG Port. Connect the device to the CIG Port. The CIG Port will start powering the device.
- Long press the CIG On/Off Button for 3 seconds to turn off the CIG Port. The CIG Port will stop powering the device.
- The CIG Port can power most car powered devices including portable refrigerator, car vacuum, car air fan, and CPAP machine.
AC Devices
- Short press the AC On/Off Button with PHOENIX on to turn on the AC Outlets. Connect the devices to the AC Outlets. The AC Outlets will start powering the devices.
- Long press the CIG On/Off Button and AC On/Off Button at the same time for 3 seconds with the AC Outlets on to switch the output frequency of the AC Outlets between 50Hz and 60Hz.
- Long press the AC On/Off Button for 3 seconds to turn off the AC Outlets. The AC Outlets will stop powering the devices.
- The AC Outlets can power most AC devices rated under 200W including laptop, monitor, TV, game console, inkjet printer, portable projector, and light bulb.
CAUTION
- Please select the output frequency of the AC Outlets in accordance with the device specifications. Inappropriate output frequency might damage the device.
- Please allow at least 4 inches (101.6 mm) of space on both sides of PHOENIX for efficient heat dissipation when the AC Outlets are in use.
NOTE
- PHOENIX might not be able to power AC devices that require high starting currents even though they are rated under 200W.
Timeout Settings
LCD Display Timeout
- When no operation is made for 5 minutes, the LCD Display will go out automatically to save energy.
- Short press the Power Button with PHOENIX on to light up or dim the LCD Display manually.
CIG Port Timeout
- When the device draws low or no power from the CIG Port for 1 hour, the CIG Port will turn off automatically to save energy.
- Long press the Power On/Off Button and CIG On/Off Button at the same time for 3 seconds with the CIG Port on to disable the CIG Port timeout.
- Turn off the CIG Port and turn it on again to re-enable the CIG Port timeout.
AC Outlets Timeout
- When the devices draws low or no power from the AC Outlets for 1 hour, the AC Outlets will turn off automatically to save energy.
- Long press the Power On/Off Button and AC On/Off Button at the same time for 3 seconds with the AC Outlets on to disable the AC Outlets timeout.
- Turn off the AC Outlets and turn them on again to re-enable the AC Outlets timeout.
Unit Timeout
- When PHOENIX is not charging, the USB-A Fast Charge Ports and the USB-C Input/Output Ports are not in use, and the CIG Port and AC Outlets are off for 1 hour, PHOENIX will turn off automatically to save energy.
Maintenance
Cleaning
- Remove all the connections from PHOENIX.
- Turn off PHOENIX.
- Clear the leaves, debris, and dust from the fans of PHOENIX.
- Clean the casing of PHOENIX with a soft dry cloth.
- Keep the area around PHOENIX clean and dry.
- Turn PHOENIX back on.
- Reconnect the devices to PHOENIX.
Storage
- Charge PHOENIX to 50%.
- Remove all the connections from PHOENIX.
- Turn off PHOENIX.
- Handle PHOENIX carefully to avoid sharp impacts or extreme pressure on the casing of PHOENIX.
- Store PHOENIX in a well ventilated, dry, clean area with temperatures between 32°F(0°C) and 113°F (45°C) and humidity lower than 75%.
- For long term storage, discharge PHOENIX to 30% and charge it to 50% every 6 months.
- Fully charge PHOENIX when it is taken out of the storage.
WARNNNG
- DO NOT expose PHOENIX to extreme temperatures above 140°F (60°F).
- DO NOT expose PHOENIX to direct sunlight, moisture, or precipitation.
- Please keep PHOENIX away from water, heat, dust, dirt, corrosives, and metal objects.
- Please ensure that no metal objects can fall on or around PHOENIX.
Troubleshooting
· If PHOENIX does not operate properly, refer to the table below for possible
causes and correc-tive steps.
· If the corrective steps do not work, contact our customer service through
renogy.com/contact-us/.
Icon| Pattern| Possible Causes|
Corrective Steps
---|---|---|---
INPUT
| Slow Flash| DC Input Overvoltage/ Undervoltage| • Disconnect the charging
source from the DC Input Port.
• Check the voltage rating of the charging source. Stop using the charging
source if its output voltage is rated lower than 10V or higher than 25V.
• Connect the charging source with the appropriate voltage rating to the DC
Input Port. Charging can be resumed.
INPUT
| Fast Flash| DC Input Reverse Polarity| • Disconnect the charging source from
the DC Input Port.
• Check the polarity of the charging source.
• Connect the charging source with the correct polarity to the DC Input Port.
Charging can be resumed.
| Slow Flash| USB-A Fast Charge Output Overvoltage/ Undervoltage| •
Disconnect the devices from the USB-A Fast Charge Ports.
• Reconnect the devices to the USB-A Fast Charge Ports.
• Contact us for help if the icons persist.
| Slow Flash| USB-A Fast Charge Output Overcurrent/ Short Circuit| •
Disconnect the devices from the USB-A Fast Charge Ports.
• Remove the short circuits if the USB-A Fast Charge Ports are shorted.
• Check the current ratings of the devices. Stop using the devices if they
draw currents that exceed the specifica- tions of the USB-A Fast Charge Ports.
• Connect the devices with the appropriate current ratings to the USB-A Fast
Charge Ports. Power can be resumed.
| Slow Flash| USB-C Output Overvoltage/ Undervoltage| • Disconnect the
device from the USB-C Input/Output Port.
• Reconnect the device to the USB-C Input/Output Port.
• Contact us for help if the icons persist.
---|---|---|---
| Slow Flash| USB-C Output Overcurrent/ Short Circuit| • Disconnect the
device from the USB-C Input/Output Port.
• Remove the short circuit if the USB-C Input/Output Port is shorted.
• Check the current rating of the device. Stop using the device if it draws
current that exceeds the specification of the USB-C Input/Output Port.
• Connect the device with the appropriate current rating to the USB-C
Input/Output Port. Power can be resumed.
| Slow Flash| CIG Output Overcurrent / Short Circuit| • Disconnect the
device from the CIG Port.
• Remove the short circuit if the CIG Port is shorted.\
• Check the current rating of the device. Stop using the device if it draws
current that exceeds the specification of the CIG Port.
• Short press the CIG On/Off Button with the LCD Display lit up to release
the protection.
• Connect the device with the appropriate current rating to the CIG Port.
Power can be resumed.
| Slow Flash| AC Output Overload/ Short Circuit| • Disconnect the devices from
the AC Outlets.
• Remove the short circuit if the AC Outlets are shorted.
• Check the power ratings of the devices. Stop using the devices if their
power ratings are higher than 200W.
• Short press the AC On/Off Button with the LCD Display lit up to release the
protection.
• Connect the devices with the appropriate power ratings to the AC Outlets.
Power can be resumed.
| Slow Flash| Inverter High Temperature| • Check if the fan inlet and outlet
are blocked.
• Cool down PHOENIX to the room temperature.
• Short press the AC On/Off Button with the LCD Display lit up to release the
protection. Power can be resumed.
---|---|---|---
OUTPUT
| Slow Flash| Total Output Overload| • Reallocate the output power to ensure
that the total output power is under 278W.
• Short press the Power On/Off Button with the LCD Display lit up to release
the protection.
• Disconnect and reconnect the device(s) to turn on the USB-A Fast Charge
Ports or USB-C Input/Output Port again. Short press the CIG On/Off Button or
AC On/Off Button to turn on the CIG Port or AC Outlets again. Power can be
resumed.
| Slow Flash| Battery High Temperature| • Disconnect all the connections from
PHOENIX.
• Check if the fan inlet and outlet are blocked.
• Cool down PHOENIX to the room temperature.
• Reconnect the charging source(s) to PHOENIX. Charging can be resumed.
• Reconnect the device(s) to turn on the USB-A Fast Charge Ports or USB-C
Input/Output Port again. Short press the CIG On/Off Button or AC On/Off Button
to turn on the CIG Port or AC Outlets again. Power can be resumed.
| Slow Flash| Battery Low Temperature| • Warm up PHOENIX.
• Charging can be resumed automatically.
• Disconnect and reconnect the device(s) to turn on the USB-A Fast Charge
Ports or USB-C Input/Output Port again. Short press the CIG On/Off Button or
AC On/Off Button to turn on the CIG Port or AC Outlets again. Power can be
resumed.
Specifications
General
Dimension| 7.48 x 6.10 x 6.99 inch / 190 x 155 x 170 mm
Weight| 5.29 lbs. / 2.4 kg
Charge Temperature| 32°F~104°F / 0°C~40°C (Recommended) 32°F~131°F / 0°C~55°C
(Extreme)
Discharge Temperature| 23°F~113°F / -5°C~45°C (Recommended)
-4°F~140°F / -20°C~60°C (Extreme)
Storage Temperature| 32°F~113°F / 0°C~45°C
Battery
Type| Lithium Ion
Capacity| 14.8V, 15000mAh / 222Wh
Cycle Life| 500 Cycles (80% DOD, 80% EOL)
Input
DC Input| 10V~25V 4A, 60W Max
USB-C Input| 5V 3A, 9V 3A, 12V 3A, 15V 3A, 20V 3A, 60W Max
Total Input| 120W Max
Output
USB-A Fast Charge Output (x2)| 5V 3A, 9V 2A, 12V 1.5A, 18W Max
USB-C Output (x1)| 5V 3A, 9V 3A, 12V 3A, 15V 3A, 20V
3A,60W Max
CIG Output (x1)| 11V~17V ****10A, 120W Max
AC Output (x1/x2)| 100V (JP)/120V (US, CA)/220V~240V (EU, UK, AU, KR,CN)
50Hz/60Hz, 200W Rated, 400W Surge
Total Output| 278W Max
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Orient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC RADIATION EXPOSURE STATEMENT
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
RENOGY.COM
Renogy reserves the right to change the contents of this manual without
notice.
US
5050 S Archibald Ave, Ontario, CA 91762
909-287-7111
www.renogy.com
support@renogy.com
CN
400-6636-695
https://www.renogy.cn
support@renogy.cn
JP
https://www.renogy.jp
supportjp@renogy.com
CA
https://ca.renogy.com
supportca@renogy.com
AU
https://au.renogy.com
supportau@renogy.com
UK
https://uk.renogy.com
supportuk@renogy.com
DE
https://de.renogy.com
supportde@renogy.com
eVatmaster Consulting GmbH
Battinastr. 30 60325
Frankfurt am Main, Germany
contact@evatmaster.com
EVATOST CONSULTING LTD
Suite 11, First Floor, Moy Road Business Centre, Taffs WelL
Cardiff, Wales, CF15 7QR
contact@evatmaster.com
References
- Renogy® Official- offer all off grid solar system products
- Renogy® Official- offer all off grid solar system products
- Solar Power Kits & Equipment for Sale | Renogy Australia
- Renogy® Canada solar off-grid items, Canadian solar panels
- Renogy bietet alle Produkte für netzunabhängige Solarsysteme anRenogy DE
- Top off-grid solar kits, lithium batteries supplies | Renogy UK
- RENOGY如果新能源 | 让每个人拥有独立清洁的能源
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>