UBIQUITI US-8-60W UniFi Switch User Guide
- June 6, 2024
- UBIQUITI
Table of Contents
- Package Contents
- System Requirements
- Hardware Overview
- Hardware Installation
- Connecting Power
- Connecting Ethernet
- Software Installation
- Adopting the UniFi Switch
- Specications
- Safety Notices
- Electrical Safety Information
- Limited Warranty
- Compliance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
US-8-60W Quick Start Guide
Click for
Table of Contents
Package Contents
System Requirements
- Linux, Mac OS X, or Microsoft Windows 7/8/10
- Java Runtime Environment 1.8 or above recommended
- Web Browser: Google Chrome (Other browsers may have limited functionality)
- UniFi Controller software v5.3.x (or newer), available at: ui.com/download/uni
IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.
Hardware Overview
Front Panel
https://dl.ubnt.com/qsg/US-8-60W/Link to https://help.ubnt.com/hc/en-
us/articles/204910134
Click for
RJ45 (Ports 1 – 4)
Table of Contents
RJ45 ports support 10/100/1000 Ethernet connections.
3. RJ45 (Ports 5 – 8)
RJ45 ports support 10/100/1000 Ethernet connections and auto-sensing 802.3af
PoE.
Top Panel
4. PoE LED (Ports 5 – 8)
Off| PoE Off
Amber| PoE On (IEEE 802.3af )
5. RJ45 Speed/Link/Act LED (Ports 1 – 8)
Off| No Link
Amber| Link Established at 10/100 Mbps
Flashing Indicates Activity
Green| Link Established at 1 Gbps
Flashing Indicates Activity
6. Ground
Optional ancillary grounding point.
7. Power
Connect the included Power Adapter to the Power port.
8. Reset Button
This button serves two functions for the UniFi Switch:
- Restart Press and release the Reset button quickly.
- Restore to Factory Default Settings Press and hold the Reset button for more than ve seconds.
Hardware Installation
Wall Mounting (Optional)
Grounding (Recommended)
The UniFi Switch is grounded through the Power Adapter; however, you can
enhance ESD protection by connecting the ancillary ground.
×Click for
Table of Contents
-
Loosen the ground screw and secure a ground wire (not included) to the grounding point.
-
Secure the other end of the ground wire to a grounding block or other grounded structure.
Connecting Power
Connecting Ethernet
Software Installation
Download and install the latest version of the UniFi Controller software at
ui.com/download/uni and follow the on-screen
instructions.
Note : If you already have UniFi Controller v5.3.x or higher installed,
go to the section, Adopting the UniFi Switch.
After you have installed the software and run the UniFi Installation Wizard, a
login screen will appear for the UniFi Controller management interface. Enter
the username and password that you created and click Sign In.
You can manage your network and view network statistics using the UniFi
Controller management interface.
To adopt the UniFi Switch, proceed to the section, Adopting the UniFi Switch.
For information on conjuring and using the UniFi Controller software, refer to
the User Guide on the website:
ui.com/download/uni
Adopting the UniFi Switch
-
From the UniFi Controller dashboard, click Devices in the left menu bar.
-
Locate the UniFi Switch in the list of devices under the Model column. Click Adopt.
-
The System LED on the UniFi Switch will turn blue to confirm that it has been successfully adopted.
Specications
US-8-60W
Dimensions| 148 x 99.5 x 30.7 mm (5.83 x 3.92 x 1.21″)
Weight| 432 g (15.24 oz)
Networking Interfaces| (8) 10/100/1000 Mbps RJ45 Ports
PoE Interfaces| (4) Ports 5, 6, 7, 8: IEEE 802.3af
Power Method| 48VDC, Max. 2A
Power Supply| External AC/DC Adapter: 100-240VAC, 50/60 Hz; 48V,
1.25A
Max. Power Consumption| 12W (Excluding PoE Output)
Max. PoE Wattage per Port| 15.4W
PoE Output (Ports 5 to 8)| IEEE 802.3af 2-Pair (Pins 1, 2+; 3,
6-)
Line Rate| 8 Gbps, Non-Blocking
LEDs
System
RJ45 Data Ports| Status
PoE; Link/Speed/Activity
ESD/EMP Protection| ± 24kV Air, ± 24kV Contact
Operating Temperature| -5 to 45° C (23 to 113° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC
Safety Notices
3. Only use attachments/accessories specified by the manufacturer.
× Click for
Table of Contents
WARNING: Failure to provide proper ventilation may cause re hazard. Keep at
least 20 mm of clearance next to the ventilation holes for the adequate arrow.
WARNING: To reduce the risk of re or electric shock, do not expose this
product to rain or moisture.
WARNING: Do not use this product in a location that can be submerged by
water.
WARNING: Avoid using this product during an electrical storm. There may
be a remote risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those species may result in improper operation, damage to the equipment, or pose is a hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification
or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
×
Click for
Table of Contents
to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operations of this equipment in a residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
| Warning: This equipment is compliant with Class A of CISPR 32. In a
residential environment, this equipment may cause radio interference.
---|---
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.
WEEE Compliance Statement
(ui.com)
Ubiquiti – Compliance
Online Resources
© 2020 Ubiquiti Inc. All rights reserved.
References
- Ubiquiti - Downloads
- Ubiquiti - Warranty
- community.ubnt.com/
- WEEE Compliance Statement
- Software Downloads - Ubiquiti
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>