SHOWVEN uFlamer Gasboom is the Safest Sas Flamer Ever User Manual
- June 1, 2024
- Showven
Table of Contents
uFlamer Gasboom is the Safest Sas Flamer Ever
“`html
Product Information
Specifications
- Product Name: uFlamer Gasboom
- Version: V1.02
- Date: 2023/09/15
- Manufacturer: SHOWVEN Technologies Co., Ltd
Product Usage Instructions
Safety Instructions
Before operating the uFlamer Gasboom system, it is crucial to
understand and adhere to the safety instructions provided in the
user manual.
1. Safety Icons Explanation
Safety icons are classified based on the severity of the hazard.
Please follow all safety instructions in this document to ensure
safe operation.
2. General Safety Instructions
-
Unauthorized repairs are prohibited as they may lead to serious
incidents. -
Ensure the power supply matches the rated voltage of the
equipment and that the socket is properly grounded. -
Connect DMX cable before powering on the uFlamer Gasboom and
ensure safety protocols are followed. -
Keep the danger area clear once the device is turned on.
-
Always have a CO2 fire extinguisher and extinguishing blanket
on hand. -
If unsure of safe operation, take the device out of service
immediately and contact SHOWVEN for assistance. -
Use high-quality aerosol and gas cartridges/bottles and keep
them away from ignition sources. -
Before exchanging consumables, shut off fuel supply and empty
remaining fuel from the system. -
The operator must have a clear view of the device to stop the
show in case of danger. -
The device should not be altered or used for other
purposes.
Product Usage Steps
-
Ensure all safety precautions are followed as per the user
manual. -
Connect the DMX cable to the uFlamer Gasboom.
-
Power on the device after ensuring safety switches are
disarmed. -
Maintain a safe distance from the device once operational.
-
Have a clear view of the device for immediate intervention if
needed. -
Use high-quality aerosol and gas cartridges/bottles during
operation. -
In case of doubt, contact SHOWVEN for assistance.
Frequently Asked Questions (FAQ)
Q: What should I do in case of a fire accident?
A: Equip yourself with a dry powder fire extinguisher for large
fires and a carbon dioxide fire extinguisher for small fires. Have
a fire blanket nearby and ensure someone is on duty during
operation.
“`
USER MANUAL uFlamer Gasboom
V1.02 2023/09/15
SHOWVEN Technologies Co., Ltd
Thanks for choosing SHOWVEN Flame system, we wish it will bring you lots of exciting moments. Please read the following user’s manual and related product installation guide carefully before operating this system.
Safety Instructions
1. Safety icons explanation
Safety instructions warn of hazards when handling equipment and provide information on how to avoid those hazards. They are classified according to the severity of the hazard and are divided into the following groups. Please do follow all safety instructions in this document!
DANGER:
Indicates a hazardous situation that, if not avoided, will result in death or serious injury. (This signal word is limited to the most extreme situations)
WARNING:
Indicates a hazardous situation that, if not avoided, could result in serious injury
CAUTION:
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE:
Provide additional or supplementary information.
2. General Safety Instructions
Unauthorized repair are prohibited, it may cause serious incident.
Make sure power supply in consistent with the rated voltage of the equipment,
and the socket must well grounded. Unplug and turn off the machine when not
use.
Please connect DMX cable before power on uFlamer Gasboom, and ensure that the
communication command is disarmed, and the safety switch of device is under
test mode.
After turning on the device, no person allows to stay in the danger area.
Ensure all persons that are part of the show be informed about the safety
distance, risks and functions of the device.
Always have a CO2 fire extinguisher and an extinguishing blanket in case of
needed.
If there be any doubt as to the safety operation of the device in any
circumstances, the device should be taken out of service immediately. Be sure
the device is in good operating condition before use. If fail to fire
correctly, immediately shut down and check it accordingly. Any questions
please always contact SHOWVEN (info@showven.cn) for help.
Be sure to use high quality aerosol, gas cartridges/bottles, otherwise, it is
easily leads to failure or danger. Please keep those consumable bottles away
from heat source, sparks, fire or other possibility of ignition. Do not smoke!
Before exchanging aerosol, gas cartridges/bottles or after each usage, please
first shut off fuel supply, then empty the remaining fuel in the system
(pipeline and gas hose) by activating the flamer several times until no flame
is being generated.
The operator responsible for the control of flame system must always have a
clear view of the device, so that he/she can stop the show immediately when
there is danger. The main AC power switch should near operator. So that
operator can turn off the power of all devices in case of abnormal.
The device shall not be altered and applied to other use purpose.
3. Disclaimers: SHOWVEN technologies Co., Ltd excludes liability for unsafe situations, accidents and damages resulting from: 1. Ignoring warnings or regulations as shown on product manual or this manual. 2. Use for other applications or circumstances other than those indicated herein. 3. Changes to the device, including use of non-original spare parts, lack of maintenance etc. 4. Dismantling device without authorization from SHOWVEN. 5. Use this machine by unqualified or untrained personnel. 6. Improper use of machine
1
Warning A dry powder fire extinguisher, a carbon dioxide fire extinguisher and
a fire blanket must be equipped next to the equipment. Someone must be on duty
during operation. In case of fire accident, dry powder fire extinguisher can
be used when the fire is large, and a carbon dioxide fire extinguisher can be
used when the fire is small.
Technical Specifications
Model: uFlamer Gasboom Housing Material: 304 stainless steel Dimension:
320×310×325mm Weight: 13kg Input: AC100-240V, 50/60Hz Work Power: 200W Usage
in Rain: Yes Battery / Standby Time: 4 * 18650 cells, about 30h Battery
Charging: Through power cable Work Pressure Range: 0-5Bar Ignition: Dual, high
voltage electron ignition Super Sensitive Flame Monitoring: Yes Solenoid
Valves: Dual, connect in series Control: DMX , 9-60V pyro signal, Wireless
with Wireless DMX Receiver (5-PIN DMX IN with DC5V power
supply) DMX: 3-pin and 5-pin DMX IN / OUT E-Stop Interface: Yes, can be
connected in series Effect Direction: Vertical Flame Height: 2-8m (depends on
nozzle type, firing duration, temperature etc.) Firing Duration: 0.1 30s
adjustable Firing Mode: Standard mode, SFT mode Fuel: Propane or Butane
Cartridge Holder:
Twin cartridge holder with 2 shut-off valves and 2 non-return valves, support
250g, 330g and 450g bottle Quadruple cartridge holder with 4 shut-off valves
and 4 non-return valves (optional), support 250g and 330g bottle. Cartridge
Interface: 7/16″ UNEF Micro Filter: Yes, installed between shut-off and non-
return valves Tip sensor: Yes Audio bracket fixing hole: Yes (Inner hole
diameter 36MM, inner hole height 62MM)
2
Structure
1. Top panel 2. Igniter (dual) 3. Flame detector 4. Fire box 5. Hot surface
icon 6. High voltage icon 7. Rear panel 8. Cartridge holder 9. Safety loop 10.
Side panel 11. Battery box 12. Audio bracket fixing hole
Cartridge holder for 2 (SFMET1063) support cartridge with outer diameter is
less than or equal to 110mm, and the height is less than 275mm.
1. Shut-off valves switch 2. Cartridge Interface 3. non-return valve 4. Quick
coupler
Cartridge holder for 4 (SFMET1108) support cartridge with outer diameter is
less than or equal to 66mm, and the height is less than 275mm.
3
Diagram of bottom panel
4
Rear Panel
1. LCD Screen 2. Power Switch (with Power indicator light) 3. 3-pin XLR
IN/OUT 4. 9-60V pyro signal port 5. Power IN 6. Safety Lock Button (with
safety mode indicator light) 7. ARM indicator light 8. 5-pin XLR IN/OUT (5-PIN
XLR IN can charge for wireless DMX pen through pin1 and 4, pin4 with DC5V
power supply) 9. E-stop interface
Display and setting
1. Display area
Indicator light
Explanation
RX
Power Input Indicator
DMX
DMX signal
ERR
Alert or Error message
ON AC Input
N/A Alert or Error
OFF No AC Input No DMX signal
No
BLINK N/A DMX connected N/A
5
SFT
SFT mode indicator SFT mode ready
2. Button functions
SFT OFF
SFT not ready yet
MENU: Switch interface to setup parameter;
+: Parameter Up
-: Parameter Down
ENTER: Confirm and save parameters (screen will flash once when parameters saved)
Note: screen display will switch to main interface if there is no operation in 10s.
3. ARM indicator light
Operators can enable/disable the arm indicator light by set the “ARM STATE” in
Advanced menu. If “ARM STATE” is ON, there will be three status: ON: no DMX
signal OFF: DMX signal input BLINK: DMX armed or Ext Ignite in advanced menu
is ON
4. Power and Safety Mode Indicator Light Power Indicator Light Light ON:
Power ON Light OFF: Power OFF
Safety Mode Indicator Light Light ON: User Mode Light OFF: Test Mode
5. Welcome interface
First Line: Product model and software version Second Line: Equipment series
number
6. Main interface
First Line: 1-1: DMX address (In 2CH-P mode, it will be displayed alternately with the safety channel address) 1-2: Flame monitoring icon. Icon occurs if firing successfully. (set “Flame Monitor” to ON in advanced menu, otherwise no such icon) 1-3: Battery Icon shows the battery status:
Below 12V 12-13V 13-14V 14-15V If the battery is flash means it is charging.
15-16V
No Battery
6
Second Line: 2-1: display SFT value under SFT mode, display “SFT:- -” in standard mode. 2-2: DMX channel mode (2CH-P, 6CH, 2CH-N), besides, it may also display alert or error message alternatively.
7. Alert Message Alert Message
E0 Test Mode E0 Factory Mode E4 ExtIgnite ON
Why it appears
Safety Switch at TEST MODE
Factory mode Ext Ignite ON
How to remove
Switch to USER MODE Switch to Normal mode
Set Ext Ignite to OFF
8. Error Message Error Message E2 Sens Break E3 VoltageErr E5 MissFire
Exceeded
E6 Tip Err E7 SFT Exceeded
E8 SFT Err
Why it appears
SFT sensor breakout
Battery voltage abnormal Consecutive ignition failures exceed the
set value of “Fl Moni Fail Num” in advanced interface
Machine slant over 45° , it stops running
SFT value exceeds the set value Not reached setting value after turning
ON SFT function for 5min
How to remove Connect SFT sensor Charge or replace new battery
Restart the machine
Tip setting set to OFF, or horizontal install machine.
Need to check the SFT sensor Need to check the coil for SFT
function
9. Interface setup For 6CH mode and 2CH-N mode
Menu
Set DMX Address
Range 1~512
For 2CH-P mode Menu
Fire Address Safety Address
Range 1~512 1~512
Default 1
Explanation DMX address setup
Default 1 2
Explanation Fire DMX address setup Safety DMX address setup
10. Advanced Interface
Press and hold “MENU” for 3s enter advanced interface, press “MENU” to switch
interface, press and hold “MENU” 3s can back to main interface.
Items
Contents
Default
Description
Drive Test
Igniter Jet Valve 1
Ignite 3 times, 1.5s per time with 0.5s interval Jet valve open 3 times, 0.5s per time with 0.5s
7
Ext Ignite
Jet Valve 2 ARM LED Fire Vol ACDC Vol Batte Vol OFF / ON
ExtIgnite Time
0s~9.9s
(Language) Mode Select Tip Setting
DMX Channel Mode
Safety Level
DefaultParamete Flame Monitor Fl Moni Value
Fl Moni Fai Num Flamepower Mode SFT Value
English / Chinese Normal Mode / Factory Mode
OFF / ON 2CH Pro Mode /6CH Mode /2CH Normal
Mode 76-120/ 102-153/ 127-178/ 153-204/ 178-229 ON/OFF
ON/OFF
0.01V-3.30V
0-10
Standard Mode /SFT Mode
30-60
ARM State
ON/OFF
OFF
0.2s
English Normal Mode
ON 2CH Pro Mode
interval ARM indicator light ON 3 times, 0.5s per time with 0.5s interval
Flame monitoring voltage Power supply voltage Battery voltage Trigger through
9-60V pyro ignition signal Ext ignite duration, this menu appears only when
Ext Ignite is ON. When set “0”, it is “JOG” mode (hold firing, release stop).
Language switch
Factory mode is for test in factory only
Turn ON/OFF tip over function
DMX channel mode switch
102-153
Available only under 2CH-P mode. Safety channel DMX value within the set threshold range, firing enabled; outside the range, firing disabled.
OFF OFF 0.35V
Reset default parameter settings Check the firing was success or not Threshold value for a successful firing
2 Standard
Mode 43
ON
Consecutive ignition failures setting
Standard mode, super flame mode Appropriate SFT value can eliminate the flame
tails after firing, high SFT value may cause poor ignition. ARM indicator
light ON/OFF setting
DMX CONTROL
uFlamer Gasboom with 3 different channel mode: 2CH-P, 2CH-N and 6CH.
2CH-P:
In this channel mode uFlamer Gasboom occupies 1 functional channel CH-F and 1
separate safety channel CH-S (this channel is independent from operational
channel, can be shared with other machine).
Channel CH-F
CH-S
Function
Value
Firing
Device enable / disable
0~110: Firing OFF 111~255: Firing ON 0~101 and 154~255: Depressurize mode, disable device (Emergency STOP) 102~153: Pressurize mode, enable device Above setting is take the default safety level (102-153) setting as an example, other safety level value setting please refer to advanced interface
8
2CH-N: In this channel mode uFlamer Gasboom occupies 2 functional channels.
Channel CH-1 CH-2
Function Firing
Firing Enable / Disable
Value
0~110: Firing OFF 111~255: Firing ON 0~239: Firing Disable (Emergency STOP)
240~255: Firing Enable
6CH:
In this channel mode uFlamer Gasboom occupies 6 functional channel. This
channel mode is designed to control the uFlamer together with CIRCLE FLAMER on
our Host Controller.
Channel
Function
Value
CH1
–
–
CH2
–
–
CH3
Firing ON/OFF
0~253: Firing OFF 254~255: Firing ON
0 and 255: permanent fire (2s is limit duration time)
CH4
Firing Duration setup
1~254: 10~2540ms duration time
(Manual firing duration = DMX Value * 10ms)
CH5
–
–
CH6
Firing Enable / Disable
0~49 and 201~255: Firing Disable (Emergency STOP) 50~200: Firing Enable
Operation
1. Safety explanation 1.1 Safety Icon Please read safety explanation
carefully before operating uFlamer Gasboom.
WARNING: The firing box, ignition probes, flame detection cover and top cover are hot, do not touch.
WARNING: High voltage between ignition probes during operation, do not touch.
1.2 Device Label
9
NOTICE: The yellow area is E-Stop interface. The device enabled only when
there is E-Stop terminal or E-Stopper connected the E-stop IN interface. 1.3
E-Stop
The E-Stop interface is power cut-off interface, and the device can be powered
on normally only after the interface is connected. E-Stop terminator (standard
configuration, SFMET1107). Put the E-Stop terminal in the E-Stop IN interface.
10
E-Stopper (optional, FPEST001). E-Stopper connects with single unit of uFlamer
Gasboom as below.
E-Stopper connects with multi units of uFlamer Gasboom in series as below:
NOTICE: E-Stopper can connect 24 units of uFlamer Gasboom in series maximum.
NOTICE: For more information about E-Stopper please check the E-Stopper
manual. 1.4 Safety Distance
The uFlamer Gasboom safety isolation zone (show as below) is a cylindrical
three-dimensional space with safety radius around machine (a) and safety
distance at firing direction (b). For safety distance at firing direction
equals to maximum firing height+2m.
11
No person and flammable materials are allowed to stay inside the safety isolation zone when flamer was armed. Unauthorized persons and objects are strictly prohibited from entering.
The safety distance a & b related with nozzle size, environment temperature, firing duration etc. We get below effect height and safety distance for your reference based on our test with two 450g gas cartridges and set firing duration at 0.2s. If necessary, please expand the safety distance according to the actual situation.
Nozzle G16, G20 and G25
Nozzle Type G16 G20 G25
Temperature Effect Height (m) Safety Radius a (m) Safety Distance b (m) Effect Height (m) Safety Radius a (m) Safety Distance b (m) Effect Height (m) Safety Radius a (m) Safety Distance b (m)
-100 1.52.5
2 4.5 2.03.0 2.5 5.0 2.53.5 2.5 5.5
010 2.53.0
2.5 5.0 3.03.5 2.5 5.5 3.54.0 2.5 6.0
1030 3.03.5
2.5 5.5 3.54.0 2.5 6.0 4.04.5 3.0 6.5
3040 2.53.0
2.5 5.0 3.03.5 2.5 5.5 3.54.0 2.5 6.0
Nozzle GA
Nozzle GA can be used with gas cartridge, and it is only suitable for 10~40.
Nozzle Type
Temperature
1015
1530
3040
Effect Height (m)
4.57.0
5.58.0
4.57.0
GA
Safety Distance a (m)
4.0
4.0
4.0
Safety Distance b (m)
9.0
10.0
9.0
WARNING: Forbidden to use Nozzle GA with gas cartridge when temperature is lower than 10.
CAUTION: For angled installation, the safety distance both around machine and firing direction should shift accordingly.
2. Battery for uFlamer Gasboom
uFlamer Gasboom can be powered through 4 pcs of 18650 cells. New Gasboom come
only with battery compartment, customer need to get 18650 cells locally. The
battery installations are as below:
a) Unscrew the screws of the battery box at the bottom panel as below. b)
Install the battery in correct direction, pay attention to the positive and
negative pole. c) Screw tight the battery box cover.
d) Active 18650 battery by connect the machine with AC power. When there is
battery icon show on LCD screen means 18650 cells was activated successfully.
e) Charging: charging automatically when machine connected with AC power
supply (no matter machine was powered on or not) NOTICE: To avoid the damage
of battery, charge the battery at least once per month. NOTICE: 18650 battery
activation is necessary whenever install the battery NOTICE: SFT mode disabled
under battery powered mode
3. Install gas cartridges for Gasboom
12
a) Before install gas cartridges please confirm safety switch stays at TEST
MODE. When safety button is pressed down, it is USER MODE; when it pops up, it
is TEST MODE.
b) Close the shut-off valves on cartridge holder. Rotate the knob clockwise to
the end position to close the shut-off valve.
c) Pull out the cartridge holder through the hole at the bottom of machine.
The cartridge holder and machine are connected with quick coupler as below,
pull out the quick coupler connection to disassemble the cartridge holder.
d) Screw the gas cartridge to cartridge holder tightly.
e) Install cartridge holder with gas cartridge back to the machine, open the
shut-off valve by rotate the knob anti-clockwise to the end position. Install
the side panel.
If use cassette gas cylinder For cassette gas cylinder, an adaptor (RMMET467)
as below was need.
13
Cassette gas cylinder
Adaptor
Installation
If use gas bottle
Disassemble the cartridge holder if use gas bottle to supply the gas for
Gasboom. And hose was needed to connect between gas bottle and Gasboom.
Gas bottle Pressure regulator
Hose
Gasboom
NOTE:
- Please choose appropriate gas bottle according to your use. 2) Please
prepare the pressure regulator by yourself.
Pressure regulator for liquefied gas and gaseous gas are different, please select appropriate pressure regulator. The pressure regulator output pressure range is 0-5Bar; Send the thread size of the output end of pressure regulator (Thread 1) to us before your order the hose from us. So that we can supply you the compatible hose with correct thread 2 sizes. 3) Hose is optional part (SFMET1136), our standard hose length is 5m, other lengths are customizable. WARNING: Do not misuse the pressure regulator between liquefied gas and gaseous gas.
WARNING: When use the gas bottle, it is mandatory to use a pressure regulator and the maximum output pressure must not be higher than 5.0 bar. The usage of gas bottles without pressure regulator is an extreme accident hazard and is strictly prohibited.
4. Install uFlamer Gasboom
a) Horizontal installation is preferred for uFlamer Gasboom. If use built in gas cartridges, Gasboom with maximum tilt angle of 45° or -45°, and it can be angled to two directions as show in below picture. But the flame height will be affect in angled installation.
14
b) If Gasboom gas supply via hose connection from gas bottle, Gasboom can be installed in any direction even upside down. But the flame height will be affect in angled installation.
c) For truss installations always connect with safety rope to ensure extra
safety. If there is any other national or regional guidelines please follow it
accordingly.
d) Double confirm the machine was firmly installed. NOTICE: For angled
installation with angles >45°, please turn off the TIP sensor.
5. Connecting uFlamer Gasboom
Make sure the DMX or pyro controller is disarmed or powered off during cable
connection.
If control by DMX controller, follow below steps:
a) Connect a DMX cable to the DMX IN socket of first unit of uFlamer Gasboom,
another head of this DMX cable connect to DMX console (such as FXcommander).
Make sure the DMX console is powered off.
b) Connect a DMX cable to the DMX OUT socket of previous uFlamer Gasboom, and
the other end to the DMX IN of next machine. Connect all devices in series in
this way.
c) Suggest to plug in a DMX terminator into the DMX OUT in last unit of
machine to improve signal reliability. For distance >200m please use SHOWVEN
DMX splitter 8 to amplify the signal.
d) Connect a power cable to the POWER IN socket of uFlamer Gasboom. Connect
the other end of power cable to the power source. Make sure power supply in
consistent with the rated voltage of the equipment, and the socket must well
grounded.
e) Each unit of uFlamer Gasboom can be connected to power supply directly. If
connect machine in sequence, please connect a power link cable to the POWER
OUT of previous machine, connect the other end of the power link cable to
POWER IN of the next machine. Do not connect exceed units to a single
electrical circuit.
f) Connect machine with E-stop terminal or E-Stopper. g) Power on all uFlamer
Gasboom. Check the safety button, double confirm it stays at “TEST MODE”.
USER MODE
TEST MODE
h) Assign DMX address for each unit of uFlamer Gasboom. If use SHOWVEN host controller or FXcommander
to control the machine please allocate a unique DMX address for each unit of machine.
15
If control by 9-60V pyro signal, follow below steps: a) Connect a power cable
to the POWER IN socket of uFlamer Gasboom. Connect the other end of power
cable to the power source. Make sure power supply in consistent with the rated
voltage of the equipment, and the socket must well grounded. b) Each unit of
uFlamer Gasboom can be connected to power supply directly. If connect machine
in sequence, please connect a power link cable to the POWER OUT of previous
machine, connect the other end of the power link cable to POWER IN of the next
machine. Do not connect exceed units to a single electrical circuit. c)
Connect the power control cables to the 9-60V pyro signal connector on uFlamer
Gasboom. d) Connect the other end of power control cables to the pyro
controller (9-60V external trigger source), such as SHOWVEN PyroSlave X16. e)
Connect machine with E-stop terminal or E-Stopper. f) Power on all uFlamer
Gasboom g) Set the Ext Ignite to ON status in advanced interface, set the
firing duration.
6. Power ON the DMX console/Pyro controller and programming Power on DMX
console and program the uFlamer Gasboom effect on DMX console
7. Test the ignition function of uFlamer Gasboom Test the ignition function
of uFlamer, we can check whether the igniters of each unit of uFlamer is
working fine. Due to the safety switch is stay at TEST MODE there will be only
ignition while jet solenoid valve is not open, so no flames generated.
8. Firing a) Double confirm the prescribed safety isolation zone is clear, no
person, animal or other property within this region. b) Switch the safety
button of uFlamer Gasboom to USER MODE.
c) Firing, the operator should always have a clear view of the device, so that
he/she can stop the show immediately when there is danger.
9. Power OFF and close the shut-off valve a) Power OFF DMX console b) Press
E-Stopper to power OFF all machine c) Close the shut-off valve for each
machine
10. Empty the remaining fuels and package machine a) Release the E-Stopper
allow machine to be power on again, firing machine several times until no
flame is being generated b) Switch safety switch of uFlamer Gasboom to TEST
MODE c) Power OFF uFlamer Gasboom d) Unplug power cable, DMX cable, E-Stopper
connection cable etc. e) Package the machine when it is cool down
Nozzles and Nozzle Replacement
1. Nozzles There are four types of Nozzle for uFlamer Gasboom.G16, G20
(standard configuration), G25, GA. The related firing height and safety
distance please check previous content of this manual.
16
WARNING: Forbid to operate uFlamer Gasboom without nozzle, it will cause accidental flame. WARNING: According to the site environment and condition, please choose appropriate type of nozzle. DANGER: Do NOT use parts or components which are not originally from SHOWVEN. NOTICE: When the device is placed or transported without packaging, please use adhesive tape to cover the nozzle to prevent foreign matter from entering.
2. Fuel Consumption
Below testing result is based on two 450g gas cartridges as show in above
picture, and firing duration is 0.2s, environment temperature is 30.
Nozzle type
G16
G20
G25
GA
0.2s flame ball quantity
Approx. 350
Approx. 270
Approx. 200
Approx. 110
3. Nozzle Replacement Use 19mm outer hexagon socket wrench (RMHDT120) to disassemble the nozzle, clean the nozzle and nozzle socket with air gun (air compressor), change a different nozzle and install it.
WARNING: Do unplug the power cable when service flamer.
Igniter Position Adjustment
Whenever changed the nozzle or ignition is not good, please check igniter pole
position according to below parameters. The right position for each pair of
pole should have a gap from tip to tip of 3.5±0.5mm and a gap between two
igniter of 52±1mm. Check the ignition success rate after adjustment by firing.
17
Maintenance
1. To maintain the machine in good performance and running status, it is
recommended to running the device at least once per month.
2. Check the ignition probes both before and after each show, if there is any
foreign objects on it please clean it up.
3. Shut-off valve maintenance: make sure no impurities in the gas cartridge
and cartridge holder connection part. If the machine not use for a long time,
it is recommended to use tape to seal this part and store it.
4. Maintenance of the nozzle: Nozzle needs to be cleaned from time to time,
and it is recommended that once every six months (depending on the environment
and frequency of use). In the process of using the equipment, if the flame
shape is seriously deformed or the fuel injection line is significantly
deformed or coarsened, the nozzle should be removed immediately for cleaning.
If after clean, there are still problems please replace new nozzle.
5. Maintenance of the O-ring: If it is found that the O-ring of the nozzle is
damaged or ageing when cleaning the nozzle, the O-ring should be replaced in
time (material and size of O-ring: fluorine rubber O-ring, the outermost
diameter is 14 mm, and the line diameter is 2 mm).
O ring 1: Inner diameter 13.2mm X wire diameter 1.8mm O ring 2: Inner diameter
5.15mm X wire diameter 1.8mm O ring 3: Inner diameter 8.0mm X wire diameter
2mm 6. Flame detector maintenance: Recommended to clean the carbon buildup on
flame detector at least once per month (depending on the use environment and
frequency), if the detector is found to be insensitive, clean it immediately.
18
Optional Parts for uFlamer Gasboom
Part. No. RMWAS070 RMWAS065 RMBOT036 RMMET045
RMEMD062
SFSMA012 SFSMA011 SFSMA013 SFSMA015 RMMET467 SFMET1107 FPEST001 RMHDT120
SFMET1136 RMSMA460 FPFLI042 SFCAB065 SFCAB204
Description G1 O ring 13.21.8 G1 O ring 5.151.8
Safety ring Safety rope Wireless receiver ( for wireless control with
FXcommander) Nozzle G20 Nozzle G16 Nozzle G25 Nozzle GA Cassette gas cartridge
Adapter G1 E-Stop terminator E-Stopper Nozzle disassemble tool 19mm hose, 5m
Quick coupler (female, external thread, R3/8) 2 in 1 flight case Waterproof
DMX cable, 6m Waterproof DMX cable, 10m
pcs / unit 1
1 1
1
1 1 1 1 2 or 4 1 1 1 1 1 1/2 1 1
19
Warranty Instructions
Sincere thanks for your choosing our products, you will receive quality
service from us The product warranty period is one year. If there are any
quality problems within 7 days after shipping out
from our factory, we can exchange a brand new same model machine for you We
will offer free of charge maintenance service for machines which with hardware
malfunction (except
for the instrument damage caused by human factors) in warranty period. Please
don’t repair machine without factory permission Below situations NOT included
in warranty service: Damage caused by use unqualified aerosol, gas
cartridges/bottles; Damage caused by improper transportation, usage,
management, and maintenance, or damage caused
by human factors; Disassemble, modify or repair products without permission;
Damage caused by external reasons (lightning strike, power supply etc.) Damage
caused by improper installation or use; For product damage not included in
warranty range, we can provide paid service. Invoice is necessary when
applying for maintenance service from SHOWVEN
20
Showven Technologies Co., Ltd.
Tel: +86-731-83833068 Web: www.showven.cn E-mail: info@showven.cn Add: Liuyang
Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>