SDC 350 Narrow Line Emlock Instruction Manual
- June 6, 2024
- SDC
Table of Contents
INSTALLATION INSTRUCTIONS
350
NARROW LINE EMLOCK
Retrofits Discontinued Locknetics 350+
Provides Superior Architectural Appearance
Electrical Instructions:
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode will cause
a delay when releasing the door and residual magnetism to occur.
Access controls and/or release contacts must be located in series with the
positive (+) power lead of the EmLock.
Any low voltage condition will cause erratic operation of the optional board
sensor.
Although SDC recommends the use of a Regulated DC power supply.
A significant voltage drop will occur when using a full-wave bridge rectifier.
Installation Location – Indoor Dry use only
PATENT NO. 5,376.910
Electrical Specifications:
Dual Voltage | 12 or 24VDC |
---|---|
Power Consumption | 560mA@12VDC |
309mA@24VDC
DS Door Status Sensor| SPDT, 250mA@24VDC
LS Lock Status Sensor| SPDT, 1A@24VDC Resistive
Any suggestions or comments to this instruction or product are welcome. Please
contact us through our website or email engineer@sdcsecurity.com
1.
Fold template as indicated on the dotted line. For single doors locate
the template against the door and header on the lock jamb side of the frame.
2.
Mark and drill holes as indicated by the template.
3.
Mount armature to door.
HOLLOW METAL DOOR
From the Sexnut side of the door, drill exactly 1/2″ hole thru one metal
thickness only. From the Armature side of the door, drill 5/8″hole to insert
reinforcement tube. Press in sex nut and reinforcement tube all the way and
mount armature to door using hardware provided.
4.
Install magnet onto the header with the magnetic stripes towards the door
side of the stop. Assure that the magnet and armature line up properly, then
tighten down ALL mounting screws.
5.
Holding the magnet housing at each end, engage the entire length of the
interlock detail, by pushing towards the door. Tap with a soft hammer to
ensure proper alignment and engagement.
CAUTION: The lock body must be held in place until secured with mounting
screws. Secure socket head screws are provided inside the housing at each end.
Start screws into threads carefully to avoid stripping the threads. Check
alignment and tighten screws. Pull wires through the frame, mounting plate,
and magnet housing
6.
Select jumper position for 12VDC or 24VDC. Connect power to magnetic
lock.
7.
Test operation. When all is operating properly, tighten all screws.
To maintain surface plating from corrosion:
- Do not touch the lock face with your hands.
- Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper).
- Apply a thin film of rust inhibitor (LPS-3) on the lock face.
- Repeat application on armature plate.
P:\INST INSTRUCTIONS\EMLOCKS\INST-350 REV A.4 09-21