PRODUCT COVERED

Model| Input voltage
(Vac, Hz)| Current
(mA)| Wattage
(W)
---|---|---|---
CFIXCNLR4S1| 120,| 60| 110| 13
CFIXCNLR6S1| 120,| 60| 130| 16
CFIXCNLR4C1| 120,| 60| 110| 13
CFIXCNLR6C1| 120,| 60| 130| 16

DIMMING
Compatible with Cync 3-wire smart switch. Do not compatible with a regular dimmer. Download Sync App for dimming and other controls.

BEFORE YOU BEGIN
Read these instructions completely and carefully.

WARNING

  • Risk of fire or electric shock. Installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation.
    Contact a qualified electrician.

  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  • This device is not intended for use with emergency exits.

  • These products are intended to be used in dry, damp, or wet locations.

  • IC rated for direct contact with insulation. PREPARE ELECTRICAL WIRING

Electrical Requirements

The LED fixture must be supplied with 120VAC 60Hz.

Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code(NEC) Article 600 and local codes.

Note: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
Risk of Damage: Must use UL approved conduit fittings for all enclosure box connections to prevent wire cuts by sharp edges and excessive strain on wiring

INSTALLATION

GE Lighting CFIXCNLR6S1 Cync Fixture Canless - 1

Turn off the power source at the main circuit breaker or fuse box.

GE Lighting CFIXCNLR6S1 Cync Fixture Canless - 2Drill a hole in the ceiling and prepare supply wire. Hole size CFIXCNLR4S1/ CFIXCNLR4C1 4 ¼ inch, CFIXCNLR6S1/ CFIXCNLR6C1  ¼ inch.

GE Lighting CFIXCNLR6S1 Cync Fixture Canless - 3Bring the supply power to the junction box through knockout and secure with strain relief. Use the wire nuts to connect power supply wires to respective color wires in the junction box.

GE Lighting CFIXCNLR6S1 Cync Fixture Canless - 4

Place the junction box on the ceiling through a cur hole. Connect the light with the junction box with the connector.

GE Lighting CFIXCNLR6S1 Cync Fixture Canless - 5.Hold the spring clips against the fixture and gently guide them into the ceiling until the clips snap into place.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

This device contains license-exempt transmitter(s)receiver(s) that comply with Innovation. Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions

  1. This device may not cause interference,
  2. This device must accept any interference, including interference that may cause undesired operation of the device.