VOLLRATH 924GGT Series Cayenne Thermostatic Heavy Duty Gas Flat Top Griddle Instruction Manual
- June 1, 2024
- VOLLRATH
Table of Contents
- VOLLRATH 924GGT Series Cayenne Thermostatic Heavy Duty Gas Flat Top
- Product Information
- Product Usage Instructions
- SAFETY PRECAUTIONS
- FUNCTION AND PURPOSE
- CLEARANCE AND ENVIRONMENT REQUIREMENTS
- Regulator Connection
- FEATURES AND CONTROLS
- BEFORE FIRST USE
- OPERATION
- CLEANING
- PREVENTATIVE MAINTENANCE
- TROUBLESHOOTING
- SERVICE AND REPAIR
- WARRANTY STATEMENT FOR THE VOLLRATH CO.
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VOLLRATH 924GGT Series Cayenne Thermostatic Heavy Duty Gas Flat Top
Griddle
Product Information
Specifications
- Model Numbers: FTT2024, FTT2036, FTT2048, FTT2060, FTT2072
- Description: Heavy-Duty Grilling Equipment
- Certifications: Conforms to ANSI STD Z83.11-2016, Certified to CSA STD 1.8-2016, Conforms to NSF/ANSI STD 4
Product Usage Instructions
Safety Precautions
Before operating the equipment, read and understand the safety precautions
mentioned below:
- WARNING: Indicates a hazard that can cause severe personal injury or death. Follow all correct precautions, procedures, and regulations for safe usage.
- CAUTION: Indicates a hazard that can cause minor or major personal injury if ignored. Pay attention to all cautions mentioned in the manual.
- NOTICE: Notes important information that is not hazard-related but essential for proper operation.
Installation
Follow these installation guidelines to ensure safe and efficient
operation:
- WARNING: Equipment must be installed by a qualified installer in compliance with federal, state, and local codes to prevent injury or death.
- Fire Hazard: Do not install or use the equipment without all 4 legs to prevent overheating and fire hazards.
- Caution: Ensure that no dirt or metal particles enter the gas lines during installation as it can damage the valve and affect operation. Use a sediment trap before the regulator.
Applicable Codes and Standards
Adhere to the following codes and standards for safe operation:
- All commercial cooking equipment must have a pressure regulator for safe operation.
- During pressure testing, disconnect the appliance and its individual shutoff valve from the gas supply piping system as per specified pressures.
- Post instructions for gas leak detection prominently as per guidelines from the local gas supplier.
Frequently Asked Questions (FAQ)
-
Q: Can this equipment be used for household purposes?
A: No, this equipment is intended for grilling foods in commercial foodservice operations only and not for household use. -
Q: What should be done if gas is smelled during operation?
A: In case of a gas smell, follow the instructions provided by your local gas supplier and post them in a prominent location near the equipment.
Operator’s Manual
Cayenne® Thermostatic Heavy-Duty Gas Flat Top Griddle
Thank you for purchasing this Vollrath equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Save the original box and packaging. Use this packaging to ship the equipment if repairs are needed.
SAFETY PRECAUTIONS
To ensure safe operation, read the following statements and understand their meaning. This manual contains safety precautions which are explained below. Please read carefully.
WARNING
Warning is used to indicate the presence of a hazard that will or can cause
severe personal injury or death.
CAUTION
Caution is used to indicate the presence of a hazard that will or can cause
minor or major personal injury if the caution is ignored.
NOTICE: Notice is used to note information that is important but not
hazard-related.
To reduce risk of injury or damage to the equipment:
- Clean the equipment per the instructions in this manual.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other equipment.
- Keep the equipment area free and clear from combustibles.
- Do not obstruct the flow of combustion and ventilation air. The equipment must have a minimum of 6″ of space on all sides.
- Use a soft cloth dampened with warm, soapy water to clean the controls and the sides of the equipment.
- Let hot equipment cool before cleaning or moving.
- Use equipment on a flat, level position only.
- Do not operate unattended.
WARNING
Fire, Injury, Death Hazard
Correct precautions, procedures and regulations for usage must be followed.
Operation and safety training is necessary for all users of this equipment.
FUNCTION AND PURPOSE
This equipment is intended to be used for grilling foods in commercial foodservice operations only. It is not intended for household, industrial or laboratory use.
Item No. | Model | Description |
---|---|---|
924GGT | ||
FTT2024 | Heavy-Duty, 24″ | |
936GGT | ||
FTT2036 | Heavy-Duty, 36″ | |
948GGT | ||
FTT2048 | Heavy-Duty, 48″ | |
960GGT | FTT2060 | Heavy-Duty, 60″ |
972GGT | FTT2072 | Heavy-Duty, 72″ |
CLEARANCE AND ENVIRONMENT REQUIREMENTS
- Must be installed adjacent to non-combustible surfaces only, with a minimum spacing of 6″ on all sides.
- Must be a minimum distance of 6″ from other equipment.
- Adequate clearance must be maintained all the way around the unit, below it, and over it to allow for proper operation.
WARNING
Fire, Injury, Death Hazard
This equipment must be installed by a qualified installer in accordance with
all federal, state and local codes. Failure to install this equipment properly
can result in injury or death.
WARNING
Fire Hazard
Do not install or use without 4″ legs. Use of this equipment without legs can
cause the appliance to overheat and cause a fire.
CAUTION
Any loose dirt or metal particles that are allowed to enter the gas lines on
this appliance will damage the valve and affect its operation. When installing
this appliance, all pipe and fittings must be free from any internal
contaminates. It is recommended that a sediment trap be installed in-line
before the regulator.
Applicable Codes and Standards
United States
Vollrath recommends that all commercial cooking equipment be provided with a
ventilation system in compliance with NFPA96.
- Cooking equipment that uses or produces grease (e.g. fryer, griddle), must be provided with hoods that are designed to capture grease and provide fire protection.
- Equipment must be installed in accordance with the requirements and approval of the AHJ “Authority Having Jurisdiction.”
NOTICE: Post instructions to be followed in the event the user smells
gas. Consult your local gas supplier for these instructions and post in a
prominent location.
NOTICE: The installation of this equipment must conform with local codes,
or in the absence of local codes, with the National Fuel Gas Code,
International Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1, as applicable.
Install and Level the Legs
Ensure that the equipment is level in all directions. Begin by tightening each
leg securely. Then, as needed at each corner, rotate the adjustable foot.
Gas Piping
- Gas piping must be sized to ensure sufficient pressure and flow to meet the full-rated gas input of the equipment.
- Connection to an existing system requires that the existing system have excess capacity equal to or greater than the full-rated gas input of the equipment.
- Joint compound (pipe dope) should be used sparingly and only on the male threads of the pipe joints. Such compounds must be resistant to the action of liquid propane (LP) gases.
Pressure Regulator
NOTICE: All commercial cooking equipment must have a pressure regulator
on the incoming service line for safe and efficient operation.
NOTICE: Prior to connecting the regulator, check the incoming line
pressure. The regulator can only withstand a maximum pressure of ¹⁄₂ PSI (14″
WC). If the line pressure is beyond this limit, a step-down regulator before
the regulator provided will be required.
NOTICE: The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/ 2 psi (3.5 kPa).
disconnected from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/ 2 psi (3.5 kPa). system by
closing its individual manual shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal to less than 1/2 psi (3.5
kPa)
- The arrow forged into the bottom of the regulator body shows gas flow direction, and should point downstream to the equipment.
- The regulator provided with this equipment is configured for use with natural gas. Following the instructions in the LP Conversion Kit, it can be reconfigured for use with LP gas.
- The equipment comes fitted with a ¾” N.P.T male adapter for connection to the pressure regulator.
- Check the pressure of the incoming gas line. The regulator can withstand a maximum pressure of 14″ WC (¹⁄₂ PSI). If the line pressure is beyond this limit, a step-down regulator will be required.
Regulator Connection
- A To gas supply with the installation of B, C and D in a vertical orientation as shown to provide for debris capture.
- B Tee
- C Nipple (any length)
- D Cap
- E Supplied Regulator
- F Vent
Orifice Sizing
NOTICE: Refer to the International Fuel Gas Code for proper orifice
sizing.
- Installer is responsible for correct orifice sizing.
- The orifice size is marked on the orifice/spud.
- Equipment is manufactured for 1035 BTU per cubic foot heat value of natural gas.
Gas Conversion
- Conversion from natural gas to liquid propane (LP) or vice versa must be performed by a qualified technician or service agent per the International Fuel Gas Code.
- Refer to the conversion kit instructions included with this equipment.
Manual Shut-Off Valve
A manual shut off valve should be installed in an accessible location within 6
ft. (1.8 m) of the equipment.
Test the Equipment
Check for Gas Leaks
NOTICE: Matches, candle flame, or any other potential source of ignition
shall not be used for this purpose.
- Rotate the gas control knob for the main burner(s) to the OFF position.
- Connect the equipment to the gas supply.
- Apply soapy water to each connection.
- Turn ON the main supply valve.
- Look for bubbles at the connections.
- Adjust the connections as needed.
Light the Pilot Burners
NOTICE : To light the pilot burner, you will need a flame source with an extension which is at least 8″ (20.3 cm) long. Hold the flame source through the opening in the front panel near the red button for the pilot light you are lighting.
- Turn OFF the main gas valve to griddle.
- Turn OFF all of the burner control valves.
- Wait 5 minutes to allow any gas to dissipate.
- Turn ON the main gas valve.
- For each main burner and pilot burner, confirm that thermocouple (currently at room temperature) is preventing the flow of gas. If the thermocouple is defective, replace it before proceeding to Step 6.
- Light the pilot burner while pressing the red button on the flame failure protection device. Hold the button for at least 10 seconds to allow the pilot flame to engage the thermocouple.
Test the Main Burners
After lighting all of the pilot burners, ensure that each main burner
functions correctly.
FEATURES AND CONTROLS
- A Griddle Plate. Cooking surface.
- B Pilot Light Access Hole. Allows access to the pilot light.
- C Knob Guard. Helps protect the control knob from damage (Heavy-Duty only).
- D Gas Control Knob. Used to set or adjust the temperature of the griddle surface.
- E Drip Tray. Collects grease and oil. This tray can be removed for cleaning.
- F Flame Failure Button. Used when igniting the pilot light. Allows gas supply to the pilot lights when the thermocouple is cold.
- G Adjustable Foot. Used to adjust the level of the equipment.
- H Leg. Supports the equipment
BEFORE FIRST USE
Burn In the Equipment
- Rotate the gas control knob(s) to the maximum setting.
- Allow griddle to heat and burn-in for approximately 30-minutes. NOTICE: You may notice smoking during this initial burn-in; this is normal.
Season the Griddle Surface
- While the griddle is warm, rub cooking oil, shortening, beef suet, or the like on the griddle surface with a clean cloth.
- Heat the griddle to medium high and allow it to operate for approximately 30 minutes.
- Rotate the gas control knob(s) to low and allow the surface to cool.
- Remove any excess oil and wipe clean.
- Repeat the process; oil, heat for 30 minutes, cool, and wipe clean.
OPERATION
WARNING
Fire, Death Hazard
If you smell gas follow the instructions provided by the gas supplier.
Do not touch any electrical switches; do not try to light the burner; do not
use a telephone within close proximity.
CAUTION
Burn Hazard
Hot liquids and steam can burn skin. Never pour any liquid other than oil to
be used for cooking onto hot surfaces.
CAUTION
Burn Hazard
Ensure that the cooking surface has cooled down before touching by hand.
- Verify that the drip tray is in place.
- Lightly oil and wipe the surface clean to remove any contaminants that may have accumulated or have seeped from the surface and/or perimeter since last use and to ensure a clean non-stick cooking surface.
- Ignite the main burner(s) by rotating the gas control knob(s). Adjust to the desired heat level.
- Preheat the griddle for 15 minutes.
- Cook the food.
- Empty the drip tray periodically to ensure that it does not overflow.
- Do not allow oil or grease to build up on the griddle. Doing so can lead to carbon build-up, which can adversely affect the performance of the griddle.
- Allow the griddle to cool at the end of each cooking cycle.
CLEANING
CAUTION
Burn Hazard
Hot surfaces and food can burn skin. Allow the hot surfaces to cool before
handling. Do not drop or spill water onto the cooking surface as it can spray
or splatter.
To maintain the appearance and increase the service life, clean your equipment
daily.
NOTICE: Do not clean the equipment with steel wool.
NOTICE: Do not use cleaning chemicals or soaps as these can be absorbed
by the surface and/or seep into the perimeter of the griddle and affect the
flavor of the food. If necessary, use only clean water, oil, and/or a food
grade degreaser for the cleaning process.
NOTICE: To prevent corrosion, do not allow the griddle surface to remain
unseasoned or without a thin coating of cooking oil.
Daily
- While the griddle is still warm, use grill brush or grill brick to remove burnt on food and grease.
- Remove, empty and clean the drip tray.
- Clean the exterior of the equipment.
- Turn off the griddle and allow it to cool.
- Apply a thin coating of cooking oil to prevent corrosion.
Weekly
- Perform the daily cleaning process. Do not apply oil to the griddle.
- Allow the griddle to cool completely.
- Thoroughly clean the griddle plate with a food-grade degreaser.
- Season the griddle. See Season the Griddle Surface under the BEFORE FIRST USE section.
PREVENTATIVE MAINTENANCE
WARNING
Fire, Injury, Death Hazard
Contact a qualified technician or service agent for any adjustments,
maintenance or repairs. This appliance is not user serviceable.
A qualified service company should check the unit for safe and efficient operation on an annual basis. Contact the factory representative or local service company to perform maintenance and repairs.
TROUBLESHOOTING
Problem | Might be Caused By | Course of Action |
---|---|---|
Smell gas. | Unknown cause. | Turn off the main supply valve, vent the area, |
call a qualified service agent.
Burner does not light.| Pilot burner not lit.| Wait 5 minutes to allow gas to
dissipate, then light the pilot burner.
Cooking surface smokes excessively.| Cooking surface not cleaned.| Allow the
cooking surface to cool down and clean while still warm; then season the top.
Cooking surface is too hot.| Insufficient ventilation.| Ensure a minimum of 6″
of space is allowed on all sides of the equipment.
Uneven cooking surface top heating.| Insufficient ventilation.| Ensure a
minimum of 6″ of space is allowed on all sides of the equipment.
Burner not operating properly.| Orifice contaminated.| Contact an authorized
service agent to service the burner.
SERVICE AND REPAIR
Serviceable parts are available on Vollrath.com.
To avoid serious injury or damage, never attempt to repair the unit yourself.
Either contact a qualified service agent for the repair or contact Vollrath
Technical Services for instructions. The appropriate phone number is listed at
the bottom of the page.
When contacting Vollrath Technical Services, please be ready with the item
number, model number (if applicable), serial number, and proof of purchase
showing the date the unit was purchased.
WARRANTY STATEMENT FOR THE VOLLRATH CO.
This warranty does not apply to products purchased for personal, family or
household use, and The Vollrath Company LLC does not offer a written warranty
to purchasers for such uses.
The Vollrath Company LLC warrants the products it manufactures or distributes
against defects in materials and workmanship as specifically described in our
full warranty statement. In all cases, the warranty runs from the date of the
end user’s original purchase date found on the receipt. Any damages from
improper use, abuse, modification or damage resulting from improper packaging
during return shipment for warranty repair will not be covered under warranty.
For complete warranty information, product registration and new product
announcement, visit www.vollrath.com.
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI 53081-3201 U.S.A. Main Tel: 800.624.2051 or 920.457.4851 Main
Fax: 800.752.5620 or 920.459.6573 Customer Service: 800.628.0830
Canada Customer Service: 800.695.8560
Technical Services
techservicereps@vollrathco.com
Induction Products: 800.825.6036 Countertop Warming Products: 800.354.1970 All
Other Products: 800.628.0832
© 2018 The Vollrath Company L.L.C.
Part No. 2350070-1 ml 6/28/18
References
- Commercial Foodservice & Kitchen Equipment | Vollrath Foodservice
- Commercial Foodservice & Kitchen Equipment | Vollrath Foodservice
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>