Ingersoll Rand QX Series Cordless Screwdriver and Nutrunner Instruction Manual

June 6, 2024
Ingersoll Rand

Ingersoll

Ingersoll Rand QX Series Cordless Screwdriver and Nutrunner

Ingersoll Rand QX Series Cordless Screwdriver and
Nutrunner

Product Safety Information

Intended Use: These Cordless Tools are designed for assembly applications requiring precise torque control, accuracy, consistency and repeatability and are recommended for tightening requirements.

WARNING : Read all safety warnings, instructions, illustrations, and specifications provided with this power tool. Failure to follow the warnings and instructions may result in electric shock, fire and / or serious injury. Save all warnings and instructions for future reference.

  • Do not puncture or burn batteries. Improper disposal may cause personal injury.
  • Use only with Ingersoll Rand IC Process Communication Module (IC-PCM) when used in radio mode.
  • Use of any other batteries may cause property damage. For additional information, refer to Cordless Screwdriver and Nutrunner Safety Manual Form 47114541, Battery Charger Safety Information Manual Form 10567832, Battery Safety Information Manual Form 10567840 and IC-PCM Safety Information Manual Form 24074205. Manual can be downloaded from ingersollrand.com

Product Specifications

model 1

Tool Model|
---|---
Family| Communication| Interface| Power| Body| Activation| Torque (Nm)| Variant| Output Type| Output Size| Voltage V, DC|

Battery Model

|

Sound Pressure Level dB(A)

| Vibration Level,

*K (EN62851)

m/s 2

QX

|

X B F

|

D N

|

2

|

P

|

T

| 004| P|

S Q

|

04

06

08

|

20

|

BL2005 BL2010 BL2012 BL2022

|

70.0

|

2.5

V

008

| P
V
E| 7.3
H

012

| P| 2.5
V
E| 5.9
H

018

| P| 73.5| 2.5
V
E| >70.0| 12.9
H
024| E| >70.0| 9.6
H

A

| 00| P V|

73.5

|

2.5

5
01
0

027

| P|

S

| 06

08

| 73.5| 2.5
V
E| >70.0| 6.9
H

5

| 02| P V|  |  |

40

|

BL4011

| 71.0| 2.5
0
03

040

| P| 71.0| 2.5
V
E| 71.5| 9.9
H

080

| P| 71.0| 2.5
V
E| 72.6| 11.9
H

*K = Vibration measurement uncertainty 3dB(A).

  • It is recommended that the tool be used in ambient temperatures (Ta) between 0°C and 45°C. However, the higher the ambient temperature, the lower the duty cycle the tool will be capable to support.

Conforms to UL STD. 62841-1 and 62841-2-2. Conforms to ANSI STD. 12.12.01-2012, Class I, Division 2, Groups A-D, T3A. Certified to CSA STD. C22.2 No. 62841-1 and 62841-2-2. Certified to CSA STD. C22.2 No 213.

Declaration of Noise and Vibration Emission
The declared vibration total value has been measured in accordance with a standard test method and may be used for comparing one tool to another. It may be used for a vibration emission level representing the main applications of the tool. However, if the tool is used for a different application, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total working period. An estimation of the level of exposure to vibration should also take into account the time when the tool is switched off or when it is running free speed.

Installation

Cable Connection:
A standard USB cable (USB to Mini Type B) can be used to connect to a computer loaded with ICS software. Maximum cable length 2 meters.

Auxiliary Handle Mounting: Mount Auxiliary Handle on Gear Case with Plastic Handle positioned in the groove. Hand tighten.
Hanger Connection: For Pistol Tool, insert ends of hanger accessory at top of housing. For Angle Tool, hang using molded feature at rear of housing.

Adjustments

WARNING: Disconnect the tool from the battery before making any adjustments or changing accessories. Such preventive safety measures reduce the risk of starting the tool accidentally.

Storage: Disconnect the battery from the tool when not in use.

Parts and Maintenance
Tool service is recommended every year or 250,000 cycles, whichever comes first. Tool repair and maintenance should only be carried out by authorized, trained personnel. When service or repair is required, contact an Ingersoll Rand office or distributor.

NOTICE:

For Authorized Trained Personnel: For ‘Assembly/Disassembly’ and other maintenance instructions regarding these products, see Maintenance Information Form 47104302, located at ingersollrand.com or contact the nearest Ingersoll Rand office or distributor.

Environmental Protection
When the life of an Ingersoll Rand electrical product has expired, it must be recycled in accordance with all applicable standards and regulations (local, state, country, federal, etc.). Improper disposal may endanger the environment.

Safety Information – Explanation of Safety Signal Words

  • DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage.
  • NOTICE Indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property.

RADIO FREQUENCY (RF) EQUIPMENT DECLARATION OF CONFORMITY

The declarations provided below pertain to the RF devices contained in the Ingersoll Rand product.

This device complies with Part 15 of the FCC Rules and complies with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.
    Warning : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, used and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Ingersoll Rand Industrial Technologies
800-D Beaty Street, Davidson, NC 28036
Phone:704-896-4000

ISED Canada User Manual Notice
This device contains licence‐exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence‐exempt RSS(s).
Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ingersoll Rand User Manuals

Related Manuals