GIANNI GK360 Series Electric Strike Instruction Manual

June 9, 2024
GIANNI

GK360 Series Electric Strike
Instruction Manual

GK360 Series Electric Strike

The GK360/361 series electric strikes are designed to accommodate cylindrical locksets with up to 3/4” (19mm) latch throw.
The strikes can be configured to fail-safe or fail-secure on site.

Specifications

Operating Voltage 12/24VDC
Current Draw 300mA/12VDC, 150mA/24VDC
Operating Temperature 32°F to 120°F (0°C to 49°C)
Humidity 0% to 85% Non-condensing
Latch Throw 3/4″(19mm) (5/8″(16mm) strike depth, 1/8″(3mm) door gap)
Keeper Width 1 6/17″ (36mm)
Static Strength 1500 lbs (680Kg) (UL Witness test: 2000Ibs)
Dynamic Strength 70 ft-lbs
Endurance 250,000 cycles (UL tested) 1,000,000 cycles (Factory tested)
Performance Level Destructive Attack: Level I

Line Security: Level I Standby Power: Level I Endurance: Level IV
Model| Latch Monitor| Body Construction
---|---|---
GK360-1224| | Zinc Alloy
GK360-ST-1224|
| Stainless Steel
GK360M-1224| •| Zinc Alloy
GK360M-ST-1224| •| Stainless Steel
GK361-1224| | Zinc Alloy
GK361-ST-1224|
| Stainless Steel
GK361M-1224| •| Zinc Alloy
GK361M-ST-1224| •| Stainless Steel

Note:
For GK360-ST-1224,GK361-ST-1224,GK360M-ST-1224,GK361M-ST-1224, remove the “Listed Fire Rated Hardware” label if the strike is used in the fail safe operation.  Using the above-mentioned strikes in Fail Safe operation negates the fire rating.

UL Requirements

For indoor use only.
Wiring methods shall be in accordance with NFPA70.
The GK360 series is intended to be used with UL Listed
Exit Hardware.
The GK360 series shall not impair the intended operation of an emergency exit.
The GK360 series shall not impair the operation of panic hardware mounted on the door.

Fail-Safe / Fail-Secure Reversible

Change screw position at fail-safe /fail-secure hole to the desired setting.

Frame Application

Compatible Locksets

Installation Instructions


Measure latch position| Mark latch position line| Attach sticker template to marked centerline
Cut hole using template| Install the mounting tabs| Connect the wires using the crimp connectors,  then test the strike, ensure to give it correct voltage.

Caution
Proper gap must be reserved between the strike keeper and latch bolt to prevent failure of solenoid valve.

Connecting Diagram

Using the Trim Plate

In case of over-cutting, use the enclosed trim plate to cover up any errors.

12/24 VDC Plug-In Wiring
For 12VDC Operation:

For 24VDC Operation:

Optional Brackets

Lip extension brackets are available for wider jambs.
Installing the Crimp Connectors:
Crimp connectors are provided to make wiring connections easier and more reliable. To install the connectors:

  1. Insert the wires into the connector.
  2. Use a crimping tool or pliers to evenly press down on the head of the connector.

Copyright © All rights reserved.
P-MU-GK360-N Published: 2022.05.27

Documents / Resources

| GIANNI GK360 Series Electric Strike [pdf] Instruction Manual
GK360 Series Electric Strike, GK360 Series, Electric Strike, Strike
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GIANNI User Manuals

Related Manuals