Product Safety Information
Intended Use:
These Cordless Tools re designed for assembly applications requiring precise torque control, accuracy, consistency and repeatability and are recommended for tightening requirement
WARNING
WARNING: Read all safety warnings, instructions, illustrations, and specifications provided with this power tool. Failue o follow the Warings and instar Lections may resultin electric shock ,fire and / or serious Injury. Save all warnings and instructions for future reference.
- Do not puncture or burn batteries. Improper disposal may cause personal injury.
- Use only with Ingersoll Rand App, IC Process Communication Module (IC-PCM), or INSIGTHqox when used in radio mode.
- Use of any other batteries may cause property damage
For additional information, refer to Product Safety Information Manual Form TL-VP2T-SIM, Cordless Screwdriver and Nutrunner Safety Manual Form TL-VP1T- SIM, Battery Charger Safety Information Manual Form 10567832, Battery Safety Information Manual Form 10567840, and Cordless Tool Controller Safety Information Manual Form 24074205.
Manual can be downloaded fromingersolrand.com
Product Specifications
QX Model identification
Model dentification
Example:
(C1D2 =Clas | Divison 2, Groups AD (s0ldn USA and Canada only)
Model| Battery Model| Sound Pressure Level dB(A)|
Vibration Level, *K (EN 62841)m/s2
---|---|---|---
QX2PMQX 20V Pistol Multiplier Series| BL2005, BL2010 BL2012, BL2013 BL2022,
BL2023|
<70.0
|
<2.5
QX5PM| BL4011, BL4013| |
QX 40V Pistol Multiplier Series| |
It is recommended that the tool be used in ambient temperatures (Ta) between 0°C and 45°C. However, the higher the ambient temperature, the lower the duty cycle the tool will be capable to support.
1212012012, Class Division 2, Groups AD, T3A. fwr Certfied to CSASTD. C22.2 No 628411 and62841-2-2. 102″ = Certfed to CSA EE STDQ22N02T
Declaration of Noise and Vibration Emission
The declared vibration total value has been measured in accordance withal standard test method and may be used for comparing one tool o another It may be used fora vibration emission level representing the main applications the tool. However, the tool is used for a different application, with different accessories or poorly maintained, the vibration emission may differ. This may significant increase the exposure level over the total working period. An estimation of the level of exposure to vibration should also take into account the time when the tool i switched of or when it s running free speed.
Installation
Cable Connection:
A standard USB cable (USB to Mini Type B) can be used to connect to a computer
loaded with ICS software. Maximum cable with 2 meters.
Auxiliary Handle Mounting:
For 20V Torque Mutiple: Mount Auxiliary Handle on Gear Case with Plastic
Handle positioned in the groove. Hand tighten For40v
Torque Mutiple: Mount Auxilary Handle on Gear Case. Rotate Auxilary
Handle to desired position and tighten screws.
Hanger Connection:
For 20V Torque Mutipler insert ends of hanger accessory at top of housing.
For40V Torque Mutipler, insert Tethering Hookin to notch ontop of Gear Case,
then insert pin to secure
Adjustments
WARNING
Disconnect the tool from the battery before making any adjustments or changing accesso- vies. Such preventive safety measures reduce the risk of starting the tool accidentally.
Storage
Disconnect the battery from the tool when not in use.
Parts and Maintenance
Tool service is recommended every year or 25,000 cycles, whichever comfit.
Tool repair and maintenance should only be carred outby atithorized, trained
personnel. When service of repair is required, contact an Ingersoll Rand
office or distributor.
NOTICE
For Authorized Trained Personnel:
For Assembly/Disasserbly’ and other maintenance instructions regarding these
products see Maintenance Information Form TP VP2T-MIM located at
ingersollrand.com o contact the nearest Ingersoll Rand office o distributor.
Environmental Protection
When the Ife of an Ingersoll Rand electrical product has expired, it must be
recydedin accordance withal applicable standards and reguiations (local,
state, country, federal,tc). Improper disposal may endanger the environment
Symbol Identification
Return waste material receding.
Do not dispose of this product with household waste material.
Product contains Lithium-lon. Do Note dispose of this product with household
waste material
Original instructions arein English. Other languages are a translatio of the original instructions
Safety Information – Explanation of Safety Signal Words
DANGER: Indicatesan imminently hazardous situation which, fnot avoided,
will result in nceath or serous injury:
WARNING: Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury or property damage.
NOTICE: Indicates information or a company policy that relates directly
or indirectly to the safety of personnel or protection of property.
This device complies with Part 15 of the FCC Rules and complies with Innovation, cience and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause harmil interference, and (2) this device must acceptany interference received, Including interference that may cause undesired operation.
Warning:
- Changes or modifications o this unit not expressly approved by the party responsible for ‘compliance could void the user’s authority to operate the equipment.
- Minimize RF exposure during Cloning Backup, utilizing Bluetooth*,the operator should maintain minimum gap of 8mim from the tool’s back cap assembly.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful Interference when the equipment is operated in cameral environment This equipment generates, used and can radiate radio frequency energy and,if not installed and used in accordance vith Thens ruction manual, may cause harmful interference 10 radio communications. Operation of this equipment i a residential area likely to catse Harmil interference inwhich case the user will be required to correct the interference at his own expense.
Ingersoll Rand Industrial Technologies
800-A Beaty Stree, Davidson, NC 28036
Phone: 704-896-4000
KCCRMIMHR1-QXX
MSIP-RMM-iR1-QXX5A
Documents / Resources
|
Ingersoll Rand QXXSTM32WB Cordless Precision Fastening Screw
Driver
[pdf] Instruction Manual
QXXSTM32WB Cordless Precision Fastening Screw Driver, QXXSTM32WB, Cordless
Precision Fastening Screw Driver, Precision Fastening Screw Driver, Fastening
Screw Driver, Screw Driver, Driver
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>