sauermann SI-CA 030 Combustion Gas Analyzer User Guide
- June 6, 2024
- sauermann
Table of Contents
- Quick start guide
- Before Using the Flue Gas Analyzer
- Analyzers description
- Operating temperature, protection of the instruments, and information
- First start-up
- ON / OFF
- Stop / Restart the Pump
- Combustion Analysis, Saving & Printing
- Software & Apps / Logiciel & Applications
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SI-CA 030
Quick Start Guide
Quick start guide
- These operating instructions describe the basic handling of the device.
- Please refer to the operating instructions available at www.sauermanngroup.com for safe use of the product and detailed information.
- Do not give this device to a child.
- The magnets in the back of the instrument can damage credit cards, hard drives, mechanical watches, pacemakers, defibrillators, and other devices that are proven sensitive to magnetic fields. It is recommended to keep the instrument at a distance of at least 25 cm (10”) away from any of these devices.
- These gas analyzers are designed to measure flue gases exhausted from combustion equipment. They are not designed for continuous operations and/or use as a control/alarm system.
KEY | FUNCTION |
---|---|
Turn the instrument on/off | |
∨ | The down key, navigate through the menu |
∧ | Up key, navigate through the menu |
OK | Confirm selection |
Enter the main menu and/or back to the previous screen |
Before Using the Flue Gas Analyzer
WARNING!
- Be sure all connections are tight to assure accurate sampling.
- When conducting measurements, the water trap/filter assembly MUST be in a VERTICAL position.
When testing is completed, always drain any accumulated condensation inside
the water trap (after EVERY test!).
The condensate is slightly acidic, so avoid contact with skin and make sure
condensate does not leak out of the water trap.
Analyzers description
- Min-DIN connection for CO and CO2 probe
- Thermocouple connection for air temperature
- Thermocouple connection for flue gas temperature
- P- connection
- P+ connection
- Gas connection
- USB connection
Operating temperature, protection of the instruments, and information
about storage
- Operating temperature: from -5 to 45 °C (23 to 113 °F)
- Protection: IP42
If the instrument is stored outside the operating temperature (for example in
a van, a warehouse,…) please let the analyzer acclimate to room temperature
for at least 15 minutes before starting and operating the analyzer.
If the ambient temperature is lower than 10 °C (50 °F), the analyzer should be
acclimated to ambient temperature before performing measurements.
First start-up
DO NOT insert the gas probe in the flue/chimney/stack.
Keep pressed for 3 seconds to turn on the analyzer.
Press the Down key to go to “Start” then press OK.
Select your country pressing Up and Down keys and validate with OK.
Select your language pressing Up and Down keys and validate with OK.
Set the date pressing OK on each line, use Up and Down keys to select the
correct item and validate with OK then go to “Next”.
Set the time pressing OK on each line, use Up and Down keys to select the
correct item and validate with OK then go to “Next”.
Set your time zone by pressing OK on each line, use Up and Down keys to select
the correct item and validate with OK then go to “Next”.
Select if you want your pump turned ON or OFF after Auto-Zero pressing OK then
go to “Save”.
Autozero is in progess.
The probe can be inserted in the chimney.
The analyzer displays the measurements.
ON / OFF
During autozero, DO NOT insert the gas probe in the chimney.
Keep pressed for 3 seconds to turn on the analyzer. Once the autozero is
finished, insert the gas probe in the chimney, and gas measurements are
displayed.
Keep pressed for 3 seconds to turn off the analyzer. Before powering off,
disconnect hoses from the analyzer and empty and dry the water trap.
Stop / Restart the Pump
Press “Main Menu” key. Press OK on the “Pump” line to activate or deactivate the pump.
Combustion Analysis, Saving & Printing
Before proceeding with the combustion analysis, remember to set the proper fuel.
Go to “Settings” and press OK.
Go to “Analysis” and press OK.
Press OK on the “Fuels” line.
Scroll through the fuels and press OK on the required one.
Once the required fuel is selected, press the “Main Menu” key until the main
menu is displayed and press OK on the “Gas analysis” line.
Measurements of the gas analysis are displayed.
You can also quickly access the fuel selection menu via the fuel shown at the
top of the combustion gas analysis screen
- To view the different measured parameters, use the Up and Down key to scroll through the various parameters.
- To save combustion data, please use the Sauermann Combustion mobile phone app.
- To print the results, use the Wireless Printer available as an option.
Software & Apps / Logiciel & Applications
Download the Sauermann Combustion App
Download the full manualhttps://sauermanngroup.com/
Customer service portal
Use our Customer service portal to contact us: https://sauermann-
en.custhelp.com
www.sauermanngroup.com
QSG – Commercial, Industrial & HVAC Analyzers 2021 – Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>