EDIMAX ES-1008PL 8 Port Fast Ethernet PoE Plus Switch Installation Guide
- June 17, 2024
- EDIMAX
Table of Contents
ES-1008PL / GS-1008PL
Quick Installation Guide
07-2014/v1.0
ES-1008PL 8 Port Fast Ethernet PoE Plus Switch
Edimax Technology Co., Ltd.
No.3, Wu-Chuan 3rd Road, Wu-Gu, New Taipei City 24891, Taiwan
Email: support@edimax.com.tw
Edimax Technology Europe B.V.
Fijenhof 2, 5652 AE Eindhoven, The Netherlands
Email: support@edimax.nl
Edimax Computer Company
3350 Scott Blvd., Bldg.15 Santa Clara, CA 95054, USA
Live Tech Support: 1(800) 652-6776
Email: support@edimax.com
COPYRIGHT
Copyright © Edimax Technology Co., Ltd. all rights reserved. No part of this
publication may be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language or computer language, in any form or
by any means, electronic, mechanical, magnetic, optical, chemical, manual or
otherwise, without the prior written permission from Edimax Technology Co.,
Ltd.
Edimax Technology Co., Ltd. makes no representations or warranties, either
expressed or implied, with respect to the contents hereof and specifically
disclaims any warranties, merchantability, or fitness for any particular
purpose. Any software described in this manual is sold or licensed as is.
Should the programs prove defective following their purchase, the buyer (and
not this company, its distributor, or its dealer) assumes the entire cost of
all necessary servicing, repair, and any incidental or consequential damages
resulting from any defect in the software. Edimax Technology Co., Ltd.
reserves the right to revise this publication and to make changes from time to
time in the contents hereof without the obligation to notify any person of
such revision or changes.
The product you have purchased and the setup screen may appear slightly
different from those shown in this QIG. The specification is subject to
change without notice. Please visit our web site www.edimax.com for the
update. All brand and product names mentioned in this manual are trademarks
and/or registered trademarks of their respective holders.
Edimax Technology Co., Ltd.
Add: No. 3, Wu-Chuan 3rd Rd., Wu-Ku Industrial Park, New Taipei City, Taiwan
Tel: +886-2-77396888
Email: sales@edimax.com.tw
PRODUCT INTRODUCTION
Model no.:
ES-1008PL: 8-Port Fast Ethernet PoE+ Switch
GS-1008PL: 8-Port Gigabit Ethernet PoE+ Switch
Package Contents
Before you start using this router, please check if there is anything missing in the package, and contact your dealer to claim the missing item(s):
- PoE switch x 1pcs
- Quick installation guide x 1pcs
- Power cord x 1pcs
- Rubber feet x 4pcs
- Rack-mount brackets and screws x 1 set
Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
- Keep the power off during the installation.
- Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded.
- Use only the power cord provided with the Switch.
- Make sure that the supply voltage matches the specifications indicated on the rear panel of the Switch.
- Ensure the vent hole is well ventilated and unblocked.
- Do not open or remove the cover of the Switch.
- Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning method.
Front Panel
Please refer to the following description for the front panel:
*ES-1008PL
LED Definitions:
LED Name | Light Status | Description |
---|---|---|
PWR | On | Switch on and correctly powered |
Off | Switch not powered or not correctly powered | |
LINK/ACT | On | The port connected |
Off | The port not connected | |
Flashing | The port is activating and transferring /receiving data. | |
Gigabit (GS-1008PL) | On | There is a 1000Mbps device connected to the |
corresponding port.
Off| There is a 10/100Mbps device connected to the corresponding port, or
there is no device connected to the corresponding port.
PoE| On| There is a PoE PD connected to the port, which supply power
successfully.
Off| No PD is connected to the corresponding port, or no power is supplied
according to the power limits of the port.
Back Panel:
Power Connector:
Plug in the female connector of the provided power cord into this AC LINE
socket, and the male into a power outlet. Supported input voltages range from
100-240V AC, and 50-60 Hz.
Product Specifications:
Model | ES-1008PL | I GS-1008PL |
---|---|---|
Standards | IEEE 802.3 1013aseT |
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3u 100BaseTX
IEEE 802.3ab 1000BaseT
IEEE 802.3af/802.3at PoE
IEEE 802.3af/802.3at PoE
IEEE 802.3x Flow Control
IEEE 802.3x Flow Control
IEEE 802.3az Energy Efficient
IEEE 802.3az Energy Efficient
Ethernet
Ethernet
Interface| RJ-45| 8 ports| 8 ports
PoE| 8 ports| 8 ports
MAC Address| 1K| 8K
Buffer Memory| 96KB| 128KB
Jumbo Frames| N/A| 9K
Total Power budget| 80W
Power Consumption| 5 Watts (Max. no PD connected)
Dimensions| 280 x 179 x 44.5 (Lx W x H)
Weight| 15 kg
Operating| 0 to 40°C
Storage Temperature| -40 to 70°C
Humidity| Operating:10 to 90% RH (non-condensing)
Note:
-
PoE budget: Up to 30 Watts max per port, 75 Watts Total
-
Please ensure you do not exceed the PoE power budget and overload the PoE switch.
For example:| 7.7W| 15.4W| 30W
---|---|---|---
Max. PoE ports (up to)| 8 ports| 4 ports| 2 ports -
Make sure the PDs that you connected to the Switch are compliant with IEEE802.3af/IEEE802.3at standard.
-
PRODUCT INSTALLATION
There are two ways to install your switch, please select one that suits you. -
Desktop Installation
1. Install the switch on a level surface that can support the weight of the unit and the relevant components, and attach the rubber feet to the bottom. The rubber feet cushion the switch and helps protect the case from scratches.
2. Plug the switch into an electrical source with the provided power cord. -
Rack-Mount Installation
Rack mounting allows for a more orderly installation when a series of network devices is being installed.
1. Disconnect all the cables from the switch.
2. Place the unit the right way up on a hard, flat surface with the front facing you.
3. Position a mounting bracket over the mounting holes on one side of the unit.
4. Insert the screws and fully tighten with a suitable screwdriver.
5. Repeat the two previous steps for the other side of the unit.
6. Insert the unit into the rack and secure with suitable screws
7. Reconnect all the cables.
-
Regarding the installation environment, we strongly recommend:
- The switch should be placed in an appropriately ventilation environment. A minimum 25 mm space around the unit is recommended.
- The switch and the relevant components should be kept away from sources of electrical noise such as radios, transmitters and broadband amplifiers.
- Avoid environments with higher than recommended moisture levels.
Troubleshooting
-
Power LED is not lit
Check if the power cord is properly connected to the plug and the
power outlet; make sure the power cord is firmly plugged into the
power socket of the switch. -
LINK/ACT LED is not lit when connected to devices
• Make sure the network device attached to the switch is turned on.
• Make sure the network cable is properly connected to the switch and the network device.
• Make sure the network cable is a UTP cable that complies with EIA/TIA 568 and Category 5 specifications.
[!] Contact your dealer if problem persist.
Appendix : The standard RJ-45 Introduction RJ45 Pin:
Below is an indication of a standard RJ-45 socket and plug, and definition for
the pins.
RJ-45 Connector pin signal:
RJ-45 Connector pin signal
Pin no.| MDI-11 signal| MDI-X signal
1| TX+| RX+
2| TX-| RX-
3| RX+| TX+
4| POE-| POE –
5| POE-| POE –
6| RX-| TX-
7| POE +| POE +
8| POE +| POE +
The following shows straight cable and crossover cable connection, ordinary
please use straight cable to connect switch/Hub or other devices:
Straight cable for the switch (uplink MDI-II port) to switch/Hub or other
devices connection
Cross over cable for switch (MDI-X port) to switch/hub or other network devices (MDI-X port) connection.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio technician for help.
FCC Caution
This device and its antenna must not be co-located or operating in conjunction
with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the authority to operate equipment.
CE Mark Warning
This is a class B product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
EU Declaration of Conformity
This equipment is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC and 2006/95/EC
WEEE Directive & Product Disposal
****At the end of its serviceable life, this product should not be treated as
household or general waste.
It should be handed over to the applicable collection point for the recycling
of electrical and electronic equipment, or returned to the supplier for
disposal.
Declaration of Conformity
We, Edimax Technology Co., LTD., declare under our sole responsibility, that the equipment described below complies with the requirements of the European Council directive (2004/108/EC and 2006/95/EC).
Equipment : 8-Port Fast/ Gigabit PoE+ Switch
Model No. : ES-1008PL / GS-1008PL
The following European standards for essential requirements have been
followed:
EMC: ENS55022:2010
EN 55024:2010
EN 61000-3-2:2006 + A2:2009
EN 61000-3-3:2008
Safety (LVD): EN 60950-1:
2006+A11:2009+A1:2010+A12:2011
Edimax Technology Co., Ltd.
No. 3, Wu Chuan 3″ Road,
Wu-Ku Industrial Park,
New Taipei City, Taiwan
Date of Signature:July, 2014
Signature:
****Printed Name:Albert Chang
Title: Director Edimax Technology Co., Ltd.
References