Z-Wave PAN30 In Wall Switch User Manual
- June 6, 2024
- Z-Wave
Table of Contents
- Z-Wave PAN30 In Wall Switch User Manual
- In Wall switch PAN30
- Introduction
- IMPORTANT
- LED Indication
- 1-2 BASIC_SET / SWITCH_BINARY_SET
- 1. Z-Wave’s Groups (Association Command Class Version 2)
- 2-1 Auto report to Grouping 1 ~ 5(Maximum Node 5)
- Binary Switch Report
- Meter Report Command:
- 2-1-3 Notification report command
- 2-2 Response to Meter Get Command
- 2-2-1 Instant Power Consumption (Watt) of Switch
- Meter Value 4 = 0xEA (W)
- 2-2-4 AC load Voltage (V)
- Meter Report Command:
- 2-2-6 load power factor (PF)
- 2-3 Multi Channel Command Class Version 4
- 2-3-1 BINARY_SWITCH_GET,
- 2-3-1 BINARY_SWITCH_SET
- 2-3-1 METER_RESET
- 2-3-1 METER_GET:
- 2-3-5-2 Get Instant Power Consumption (Watt) from endpoint
- PAN30 Instant Power Consumption (W) Report example
- 2-3-5-3 Get load voltage V from endpoint
- 2-3-5-5 Get power factor PF from endpoint
- 3. Z-Wave’s Configuration
- 3-1 Watt Meter Report Period:
- 3-2 KWH Meter Report Period:
- 3-1 Threshold of current for Load Caution
- 3-2 Threshold of KWh for Load Caution
- 3-3 External switch mode
- 3-4 Restore switch state mode
- 3-5 Watt differential report mode :
- 3.Firmware update over the air (OTA)
- 4. Command Classes
- Disposal
- FCC Interference Statement
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Z-Wave PAN30 In Wall Switch User Manual
In Wall switch PAN30
Introduction
This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus
TM enabled device and is fully compatible with any Z-WaveTM enabled network.
Mini size design let the module can easily hide itself into the wall box and
that will be good for the house decoration.
There are many kind of application by using the module to switch AC power On
and Off, one main application is the light control. The new smart relay
calibration technology can reduce the inrush current caused by the load and
let the module work perfectly with many kind of light like incandescent,
fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of connected light or appliances. When detect- ing overload state, the Module will be disabled and its On/Off button will be lock- out of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network
Safety Precautions and Installation
- Avoid installing the unit in storming or raining weather.
- Be sure to isolate or switch off power source before installing or maintenance.
- Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse.
IMPORTANT
- Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation.
- Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods. Before proceeding with the installation, TURN OFF THE POWER TO THE
LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.
Specification
Operating Voltage | 100-240VAC 50Hz-60Hz |
---|---|
Maximum Load | 6.5A x 2 Channel (@230Vac/120Vac) (Resistive load) |
Range | Minimum 40 m in door 100m outdoor line of sight |
Operating Temperature | 0°C ~ 40°C |
Humidity | Up to 85% max. |
Storage Temperature | -20°C to 60°C |
Location | Indoor use only |
Frequency Range | 868.40MHz; 869.85MHz (EU) |
908.40MHz; 916.00MHz (USA/Canada)
920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)
RF Power| +10dBm (Peak), -10dBm (Average)
Communication Protocol| Z-wave™
OTA| Yes
FCC ID| RHHPAN30
Dimensions| 47.5 x 39 x16 mm
Wire| 0.75mm² , 18AWG
** Specifications are subject to change and improvement without notice.
Troubleshooting
2. The Switch break down | send it for repair. |
---|
The Switch LED illuminating, but cannot control the ON/OFF
Switch of the load attached
| Check if the load connect into the Switch has its own ON/OFF switch| Set the
ON/OFF switch of the load attached to ON
The Switch LED illuminating, but the Detector cannot control
the Switch
| 1. Not carry out association
2. Same frequency interference
| 1. Carry out association
2. Wait for a while to re-try
LED keep flashing, but cannot control| Overload occurs| Remove the load attached or check max. load cannot exceed
7.5A(Resistive load)
Installation Steps
- Connect PAN30 to AC N and L.
- Connect Load1 and Load2 to NO1 and NO2.
- Connect external Switch to S1 and S2.
Fig 1. Assembling
For Instruction to http:// www.philio-tech.com
DANGER Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage. Choosing a Suitable Location
- Do not locate the Module facing direct sunlight, humid or dusty place.
- The suitable ambient temperature for the Module is 0°C~40°C.
- Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
- After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which
is used to toggle switch on and off or carry out inclusion, exclusion, reset
or association. When first power is applied, its LED flashes on and off
alternately and repeatedly at 0.5 second intervals. It implies that it has not
been assigned a node ID and start auto inclusion.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-WaveTM Certificated Primary Controller to
access the Setup function, and to include/exclude/associate devices
Function | Description | Annotation |
---|---|---|
No node ID | The Z-Wave Controller does not allocate a |
node ID to the Switch.
| LED 2-second on,
2-second off
Inclusion| 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the
controller manufacturer.
| One press one flash LED
2. Pressing INCLUDE_BUTTON three times
within 2 seconds will enter inclusion mode.
SmartStart| 1. To initiate the SmartStart process, please type in the first five digits of DSK string or scan the QR code. The QR Code can be found on PAN30 or in the box. Ex:
DSK: 18112-24021-58001-62259-
57092- 27453-08187-47408
2. PAN30 is supported with SmartStart, it can be added to Z-Wave™ network by scanning the Z-Wave™ QR code on the product.
3. Without further actions, PAN30 will be au- tomatically included in a certified Z- Wave™ Controller with SmartStart inclu-
sion ability in 10 minutes after it turned on.
|
---|---|---
Exclusion| 1. Put your Z-Wave controller into exclusion mode by following the
instructions provided by the
controller manufacturer.
| One press one flash LED
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion
mode.
3. Node ID has been excluded.| LED 0.5s On, 0.5s
Off (Enter auto inclusion)
Reset| 1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter
inclusion mode.
| Use this proce- dure only in
the event that the primary
controller is lost or otherwise inopera-
ble.
---|---|---
2. Within 1 second, press On/Off button again for 5 seconds.
3. IDs are excluded.| LED 0.5s On, 0.5s
Off (Enter auto inclusion)
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a
node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when PAN30 already installed in a wall box. To solve this issue, PAN30 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when first time connect to main power.
LED Indication
There is a LED for identify function in the front case. PAN34 support the
indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05.
To distinguish what mode the switch is in, view from the LED for
identification.
State
Type
| LED Indication
---|---
Normal| Whatever we switch On and off of the PAN30 by S1 S2 or On/ Off button
or RF command, the LED will lights up 1 second
and then off.
No node ID| Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will
stop flashing temporarily.
Learning| When PAN30 is in learning mode, LED flashes on and off al-
ternately and repeatedly at 0.5 second intervals.
Overload| When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.2 second intervals. Overload state can be cleared by disconnect and reconnect
the Switch to the main power
Installation
- Put the in wall switch into a wall box and connect the AC power wire L,N to PAN30 connector L, N.
- Connect the wall switch to the PAN30 as Fig1 .
- To manually turn ON the Switch, press and release the On/Off button. The LED will light ON for 1 second, and the load plugged into the Switch will also turn ON.
- To manually turn OFF the Switch, simply press and release the On/Off button. The LED will light ON for 1 second and the load plugged into.
the Switch will turn OFF.
Programming
- Basic Command Class / Binary Switch Command Class PAN30 respond to BASIC and BINARY SWITCH commands that are part of the Z-Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET Since the switch have two relay, the Switch will report its On/Off state of relay1 and relay2. Report ON when relay1 or relay2 is ON.Report OFF when both relay1 and relay2 are OFF.
1-2 BASIC_SET / SWITCH_BINARY_SET
Since PAN30 has two relay, all the loads attached to relay1 and relay2 will turn on or off upon receipt of the following commands from a Z-Wave Controller.
[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)] : the load
attached to relay1 and relay2 turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)] : the load attached to
relay1 and relay2 turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99,
255(0xFF)] : the load attached to relay1 and relay2 turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)] : the load attached to relay1 and relay2 turns off.
1. Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to the associated Z-Wave devices. It
supports groups which every group has five nodes support. Group1 is called
Lifeline which support SWITCH_BINARY_REPORT
METER_REPORT 、NOTIFICATION_REPORT、INDICATOR_REPORT and
DEVICE_RESET_LOCALLY_NOTIFICATION.
Group2 and Group3 support SWITCH_BINARY_REPORT. Group4 and Group5 support
METER_REPORT
For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
For group 2, the Switch will report ON/OFF status of Relay1. For group 3, the
Switch will report ON/OFF status of Relay2.
For group 4, the Switch will report Instant Power Consumption (Watt) and
Accumulated Power Consumption (KWh) of Relay1.
For group 5, the Switch will report Instant Power Consumption (Watt) and
Accumulated Power Consumption (KWh) of Relay2.
2-1 Auto report to Grouping 1 ~ 5(Maximum Node 5)
2-1-1 On/Off Event Report
When “on” or “off” state of relay1 has been changed, it will send Binary Switch Report to the nodes of Group1 and Group2. When “on” or “off” state of relay2 has been changed, it will send Binary Switch Report to the nodes of Group1 and Group3. The report value will be on when relay1 or relay2 is on, it will be off when both relay1 and relay2 are off.
Binary Switch Report
ON: [Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)] OFF: [Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report When the power consumption
of load vary over 5%, it will send Meter report
to the nodes of Group1、Group4 and Group5
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
2-1-3 Notification report command
When PAN30 detect the overload, it will send Notification Report to Group1.
The content of Notification Report
Notification report command: [Command_Class_Notification, Notification_Report,
Notification Type = 0x08, Event state = 0x08]
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5) load power factor (PF) to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] Meter
Report Command: [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type
= 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W)]
Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W 2-2-2 Accumulated Power
Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)] Meter
Report Command: [Command Class Meter,Meter Report,Rate Type = 0x01, Meter Type
=0x01, Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]
Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Value 3*256) + (Meter Value 4) = 800.35 (KW/h)
2-2-3 Clearing accumulated power consumption Whenever re-start counting the
accumulated power consumption is needed, you can use Meter Reset Command to
clear it.
Meter Reset Command: [Command Class Meter, Meter Reset]
2-2-4 AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision = 1,Scale = 0x04,Size = 2, Meter Value(V)]
Example:
Scale = 0x04 (V)
Precision = 1
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) 2-2-5 AC
load current ( I )
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] Meter
Report Command: [Command Class Meter,Meter Report,Rate Type = 0x01,Meter
Type = 0x01,Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)]
Example:
Scale = 0x05 (I)
Precision = 2
Size = 2 (2 Bytes of I)
Meter Value 1 = 0x01(I)
Meter Value 2 = 0x21(I)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
2-2-6 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] Meter
Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,
Precision = 2,Scale = 0x06,Size = 1 Bytes,Meter Value(PF)]
Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
2-3 Multi Channel Command Class Version 4
PAN30 also support Muti Channel command class (version 3), which include
BINARY_SWITCH_GET, BINARY_SWITCH_SET, BASIC_GET, BASIC_SET,
METER_SUPPORTED_GET, METER_RESET, METER_GET
You may control endpoint 1 and 2 or get meter report from endpoint 3 and 4 of
PAN30.
2-3-1 BINARY_SWITCH_GET,
You may get the ON/OFF state from endpoint 1 and 2, when endpoint set to 1, PAN30 will reply state of Relay1. If endpoint set to 2, PAN30 will reply state of
Relay2.
Below is an example show a source endpoint 1 send a Get command to PAN30 endpoint 2.
COMMAND_CLASS_MULTI_CHANN EL|
(this is the endpoint of command inquirer here we assume endpoint is 1, if the inquirer doesn’t support multi Channel this value will be 0)
(Bit Address =0;Destination End Point range from 1~2)
(Command Class Switch Binary = 0x25) (Switch Binary Get = 0x02)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x02)
Command Class = 0x25
Command =0x02
Below is the example show PAN30 report to last command
Source End Point = 0x02| Since the endpoint is 2 so PAN30 will reply ON(0xFF) when Relay2 is ON, report OFF (0x00) when Relay2 is OFF
(Bit Address =0;Destination End Point)
(Command Class Switch Binary = 0x25)
(Switch Binary Report = 0x03) (ON=0xFF , OFF=0x00)
---|---
(Bit Address +Destination End Point = 0x01)
Command Class = 0x25
Command =0x03
Parameter 1 = 0xFF
2-3-1 BINARY_SWITCH_SET
**** By using BINARY_SWITCH_SET Command of Multi Channel Command Class Encapsulation Command, you can switch Relay1 ON/OFF by setting
COMMAND_CLASS_MULTI_CHANN EL|
---|---
MULTI_CHANNEL_CMD_ENCAP
endpoint to 1, or switch Relay2 ON/OFF by setting endpoint to 2.
The example of the command show that switch off relay1 of PAN30
COMMAND_CLASS_MULTI_CHANNE L|
(this is the endpoint of command inquirer here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x01)| (Bit Address =0;Destination End
Point range1~2)
(Command Class Switch Binary = 0x25)
(Switch Binary Set = 0x01)
---|---
Command Class = 0x25
Command =0x01
Parameter 1 = 0x00| (ON=0xFF , OFF=0x00)
2-3-5 METER_GET:
Using meter get command to get the KWH, W, V, I, PF from endpoint of PAN30
2-3-5-1 Get KWH from endpoint
Meter GET example:
COMMAND_CLASS_MULTI_CHANNE L|
(this is the endpoint of command inquirer here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)| (Bit Address =0;Destination End
Point range 3~4)
( Command_Class_Meter_V3 = 0x32) (Meter Supported Get = 0x03)
---|---
Command Class = 0x32
Command =0x03
Below is the example show PAN30 report to last command
COMMAND_CLASS_MULTI_CHANNEL
|
(Command_Class_Meter_V3 = 0x32) (Meter Supported Report = 0x04) (Meter Reset =1, Meter Type=0x01)
(Scale Supported =
KWh+W+V+A+Power Factor = 0x75)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x04
Parameter 1 = 0x81
Parameter 2 = 0x75
2-3-1 METER_RESET
**** This command is to reset the Accumulated Power Consumption (KWh) to 0 The example show how to reset the KWh
COMMAND_CLASS_MULTI_CHANNEL
|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
(Bit Address =0;Destination End Point range3~4)
( Command_Class_Meter_V3 = 0x32) ( Meter Reset = 0x05)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x05
2-3-1 METER_GET:
Using meter get command to get the KWH, W, V, I, PF from endpoint of PAN30 2-3-5-1 Get KWH from endpoint Meter GET example
COMMAND_CLASS_MULTI_CHANNEL
|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point =| (Bit Address =0;Destination End
---|---
0x03)| Point range3~4)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)
Command =0x01| (Meter Get = 0x01)
Parameter 1 = 0x00| (Scale = KWH = 0x00)
Accumulated power consumption (KWH) Report example
COMMAND_CLASS_MULTI_CHANNEL
|
(Meter report = Endpoint3)
(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32)
(Meter Report = 0x02)
(Scale Bit2 = 0 ,Rate Type = 0x01,
Meter Type=0x01)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0x21
Parameter 2 = 0x44| (Precision = 2,Scale Bit1Bit0 =
---|---
| 0,Size = 4)
Parameter 3 = 0x00| Accumulated Power Consumption =
Parameter 4 = 0x00| 0x000005FD = 15.33 KWh
Parameter 5 = 0x05|
Parameter 6 = 0xFD
2-3-5-2 Get Instant Power Consumption (Watt) from endpoint
**** METER_GET example
COMMAND_CLASS_MULTI_CHANN EL|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
(Bit Address =0;Destination End Point range 3~4)
( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
PAN30 Instant Power Consumption (W) Report example
COMMAND_CLASS_MULTI_CHANNEL
|
(Meter report = Endpoint3)
(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32)
(Meter Report = 0x02)
(Scale Bit2 = 0, Rate Type = 0x01, Meter Type=0x01)
(Precision = 1,Scale Bit1Bit0 = 0x02,Size = 4)
Instant Power Consumption = 0x000003EA
= 100.2W
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0x21
Parameter 2 = 0x34
Parameter 3 = 0x00
Parameter 4 = 0x00
Parameter 5 = 0x03
2-3-5-3 Get load voltage V from endpoint
Meter GET example:
COMMAND_CLASS_MULTI_CHANNE L|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
(Bit Address =0;Destination End Point range3~4)
( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)
(Scale = V = 0x04)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x20
PAN30 AC load Voltage report example:
COMMAND_CLASS_MULTI_CHANNEL
|
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03| (Meter report = Endpoint3)
(Bit Address =0;Destination End Point
= command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32) (Meter Report = 0x02)
(Scale Bit2 = 1, Rate Type = 0x01, Meter Type=0x01)
(Precision = 1, Scale Bit1Bit0 = 0x00, Size = 2)
Voltage = 0x0910 = 232.0V
---|---
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x22
Parameter 3 = 0x09
Parameter 4 = 0x10
2-3-5-4 Get load current I from endpoint Meter GET example:
COMMAND_CLASS_MULTI_CHANNEL
|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point =| (Bit Address =0;Destination End Point
---|---
0x03)| range1~3)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)
Command =0x01| (Meter Get = 0x01)
Parameter 1 = 0x28| (Scale = A = 0x05)
AN30 AC load current (I) example:
COMMAND_CLASS_MULTI_CHANNEL
|
(Meter report = Endpoint3)
(Bit Address =0;Destination End Point
= command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32) (Meter Report = 0x02)
(Scale Bit2 = 1, Rate Type = 0x01, Meter Type=0x01)
(Precision = 2, Scale Bit1Bit0 = 0x01,
Size = 2)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x4A
Parameter 3 = 0x00| Current = 0x002B = 0.43A
---|---
Parameter 4 = 0x2B
2-3-5-5 Get power factor PF from endpoint
Meter GET example:
COMMAND_CLASS_MULTI_CHANNE L|
(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)
(Bit Address =0;Destination End Point range3~4)
( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)
(Scale = PF = 0x06)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address+Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x30
L
|
(Meter report = Endpoint3)
(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32) (Meter Report = 0x02)
(Scale Bit2 = 1, Rate Type = 0x01, Meter Type=0x01)
(Precision = 2, Scale Bit1Bit0 = 0x10, Size = 1)
Power Factor = 0x63 = 0.99
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x51
Parameter 3 = 0x63
3. Z-Wave’s Configuration
Configurat ion
Parameter
| Function| Size (Byte)| Value| Unit| Default|
Description
---|---|---|---|---|---|---
1| Watt Meter
Report Period
| 2| 0 –
0x7FFF
| 5s| 720| 720*5s=3600s=
1 hour
2| KWH Meter
Report Period
| 2| 0 –
0x7FFF
| 10min| 6| 6*10min= 1 hour
3| Threshold of current for
Load Caution
| 2| 10-750| 0.01A| 750| 750*0.01A =
7.5A
---|---|---|---|---|---|---
4| Threshold of KWH for Load
Caution
| 2| 1-10000| 1KWh| 10000|
5| External switch mode| 1| 1-3| | 1| 1:Edge mode
2:Pulse mode 3:Edge-Toggle
mode
6| Restore switch state mode| 1| 0-2| | 1| 0 : Switch off 1 : Last switch
state
2 : Switch on
7| Watt differential report mode| 1| 0-4| | 1| 0 : Disable
1 : 5%
| | | | | 2 : 10%
| | | | | 3 : 15%
| | | | | 4 : 20%
3-1 Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN30 will report
its instant power consumption every 1 hour to the node of correspond Group.
The maximum interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr). If the setting value is 0, the auto report function of
meter Watt will be disabled.
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN30 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report function of meter KWh will be disabled.
3-1 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN30 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
3-2 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN30 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
3-3 External switch mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.
- Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and if the PAN30 relay change the state because of
receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state.
- Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or
- Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or
3-4 Restore switch state mode
Whenever the AC power return from lost, PAN30 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.
3-5 Watt differential report mode :
It will trigger a Watt report when the variation of watt value is over the preset percentage.
- Disable : The function of Watt differential report will be
- 5% : When the differential value of Watt is over 5%, PAN30 will send a meter report to the associated
- 10% : When the differential value of Watt is over 10%, PAN30 will send a meter report to the associated
- 15% : When the differential value of Watt is over 15%, PAN30 will send a meter report to the associated
- 20% : When the differential value of Watt is over 20%, PAN30 will send a meter report to the associated
3.Firmware update over the air (OTA)
PAN30 is based on 700 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z- wave RF media. It is a helpful and convenient way to improve some function if needed.
4. Command Classes
The Switch supports Command Classes including…\
Command Class | Version | Required Security Class |
---|---|---|
Z-Wave Plus Info | 2 | None |
Security 0 | 1 | None |
Security 2 | 1 | None |
Supervision | 1 | None |
Transport Service | 2 | None |
Association | 2 | Highest granted Security Class |
Association Group Information | 3 | Highest granted Security Class |
Basic | 2 | Highest granted Security Class |
Binary Switch | 2 | Highest granted Security Class |
Configuration | 4 | Highest granted Security Class |
Device Reset Locally | 1 | Highest granted Security Class |
Firmware Update Meta Data | 5 | Highest granted Security Class |
Indicator | 3 | Highest granted Security Class |
Manufacturer Specific | 2 | Highest granted Security Class |
Meter | 5 | Highest granted Security Class |
Multi Channel Association | 3 | Highest granted Security Class |
Multi Channel Command | 4 | Highest granted Security Class |
Notification | 8 | Highest granted Security Class |
Powerlevel | 1 | Highest granted Security Class |
Version | 3 | Highest granted Security Class |
Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Philio Technology Corporation
8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City
24257,Taiwan(R.O.C)
www.philio-tech.com
FCC Interference Statement
This equipment has been tested and found to comply with the limit’s fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea- sonable protection against harmful interference in a residential installation. This equip- ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio com- munications. However, there is no guarantee that interference will not occur in a particu- lar installation. If this equipment does cause harmful interference to radio or television re- ception, which can be determined by turning the equipment off and on, the user is en- couraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
- Consult the dealer or an experienced radio/TV technician for
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired
FCC Caution: Any changes or modifications not expressly approved by the party respon- sible for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.