sauermann CLASS 120 KISTOCK KT 120 Data Loggers User Manual Product Information

May 15, 2024
sauermann

CLASS 120 KISTOCK KT 120 Data Loggers

Product Information

Specifications

  • Units displayed: Temperature, humidity

  • Resolution: N/A

  • External input: USB connector

  • Internal sensor: Temperature: NTC, Humidity:
    capacitive

  • Type of sensor: NTC for temperature,
    capacitive for humidity

  • Measuring range: Temperature: N/A, Humidity:
    N/A

  • Setpoint alarms: 2 setpoint alarms on each
    channel

  • Number of points: 50,000

  • Frequency of measurement: From 1 minute to 24
    hours

  • Working temperature: N/A

  • Storage temperature: N/A

  • Battery life: 3 years

  • European directives: 2011/65/EU RoHS II;
    2012/19/EU WEEE; 2014/30/UE EMC; 2014/30/UE

Product Usage Instructions

1. Safety Instructions

1.1 Precautions for Use

Please always use the device within the parameters described in
the technical features to ensure protection.

1.2 Symbols Used

Follow the procedures in the user manual and pay attention to
notes marked with specific symbols for safety.

2. Presentation of the Device

2.1 Use

The KT 120 and KH 120 data loggers measure temperature and
humidity and are ideal for food transport.

2.2 Applications

The KISTOCK data logger is suitable for temperature and humidity
control in sensitive food storage areas like refrigerators, cold
rooms, and food trucks.

2.3 Description of the Device

The device has a display, selection key, USB connection cap, and
an OK key for various functions.

2.4 Description of the Keys

The OK key is used to validate, start or stop records, while the
selection key allows for scrolling through functions.

2.5 PC Connection

The device features a USB male connector for PC connection.

2.6 Fixation

The KT 120 and KH 120 data loggers have magnetic mounting for
easy fixing.

3. Technical Features

4. Use of the Device

The display shows “END DATASET” when the dataset is
finished.

Frequently Asked Questions (FAQ)

Q: What is the warranty period for the KISTOCK data

loggers?

A: The KISTOCK data loggers have a 1-year guarantee for any
manufacturing defects.

USER MANUAL
CLASS 120 KISTOCK KT 120 ­ KH 120

2

Table of contents
1 SAFETY INSTRUCTIONS……………………………………………………………………………………………………………………………… 4 1.1 Precautions for use…………………………………………………………………………………………………………………………….. 4 1.2 Symbols used……………………………………………………………………………………………………………………………………. 4
2 PRESENTATION OF THE DEVICE…………………………………………………………………………………………………………………… 5 2.1 Use…………………………………………………………………………………………………………………………………………………. 5 2.2 Applications……………………………………………………………………………………………………………………………………… 5 2.3 Description of the device……………………………………………………………………………………………………………………..5 2.4 Description of the keys……………………………………………………………………………………………………………………….. 5 2.5 PC connection…………………………………………………………………………………………………………………………………… 5 2.6 Fixation……………………………………………………………………………………………………………………………………………. 6
3 TECHNICAL FEATURES………………………………………………………………………………………………………………………………. 6 3.1 Devices……………………………………………………………………………………………………………………………………………. 6 3.2 Housing…………………………………………………………………………………………………………………………………………… 7 3.3 Dimensions………………………………………………………………………………………………………………………………………. 7 3.4 Warranty period…………………………………………………………………………………………………………………………………. 7
4 USE OF THE DEVICE………………………………………………………………………………………………………………………………….. 8 4.1 Display…………………………………………………………………………………………………………………………………………….. 8 4.2 Functions of keys………………………………………………………………………………………………………………………………..8 4.2.1 Groups organisation………………………………………………………………………………………………………………….. 10 4.3 Data logger configuration with the integrated PDF file……………………………………………………………………………..10 4.4 Data logger download with PDF report edition……………………………………………………………………………………….13 4.5 Configuration, data logger download and data processing with the KILOG software………………………………………14
5 DEVICE MAINTENANCE…………………………………………………………………………………………………………………………… 15 5.1 Replace the battery………………………………………………………………………………………………………………………….. 15 5.2 Device cleaning……………………………………………………………………………………………………………………………….. 15
6 CALIBRATION………………………………………………………………………………………………………………………………………… 16 7 ACCESSORIES………………………………………………………………………………………………………………………………………… 16 8 TROUBLESHOOTING………………………………………………………………………………………………………………………………… 16
3

1 SAFETY INSTRUCTIONS
1.1 Precautions for use
Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device.
1.2 Symbols used
For your safety and in order to avoid any damage of the device, please follow the procedure described in this user manual and read carefully the notes preceded by the following symbol:
The following symbol will also be used in this user manual: Please read carefully the information notes indicated after this symbol.

4

SAFETY INSTRUCTIONS

2 PRESENTATION OF THE DEVICE
2.1 Use
The KT 120 and KH 120 data loggers of the HVAC range allow the internal measurement of temperature only (KT 120) or of temperature and humidity (KH 120). This class of devices is dedicated to the food transport.
The devices have a male USB plug and an integrated software in PDF format which enables to download and configure the data logger without specific software.
2.2 Applications
The KISTOCK data logger is ideal for a temperature and humidity control for the sensitive foodstuff storage, for example in the food industry or pharmaceutical domain. It allows to control the temperature and humidity in refrigerators, cold rooms, food trucks etc.
Therefore, the device guarantees a traceability all along the cold chain. And at any moment the KISTOCK data logger allows to edit easily and quickly a data report in PDF format.
2.3 Description of the device

Display

“Selection” key USB connection cap

“OK” key

2.4 Description of the keys
“OK” key: allows to validate, start or stop the records, display the value “Selection” key: allows the functions scroll
2.5 PC connection

USB male connector PRESENTATION OF THE DEVICE

Unlosable cap 5

2.6 Fixation
The KT 120 and KH 120 KISTOCK data loggers have a magnetic mounting, so you can fix it easily.
Magnetic mounting

3 TECHNICAL FEATURES

3.1 Devices
Units displayed Resolution External input Internal sensor Type of sensor Measuring range

KT 120 °C, °F 0.1°C, 0.1°F
Temperature NTC
From -40 to +70°C

KH 120
°C, °F, %RH
0.1°C, 0.1°F, 0.1%RH
USB connector
Temperature, humidity Temperature: NTC Humidity: capacitive
Temperature: From -20 to +70°C Humidity: From 0 to 100%RH

Accuracies*

±0.4°C from -20 to 70°C ±0.8°C below -20°C

Temperature: ±0.4°C from 0 to 50°C ±0.8°C below 0°C or above 50°C
Humidity**: ±2.5%RH (from 5 to 95%RH, 15°C to 25°C)

Setpoint alarms Number of points Frequency of measurement Working temperature Storage temperature Battery life European directives

2 setpoint alarms on each channel

50 000

From 1 minute to 24 hours

From -40 to +70°C

From -20 to +70°C

From -40 to +85°C

3 years***

500 days***

2011/65/EU RoHS II; 2012/19/EU WEEE; 2014/30/UE EMC; 2014/30/UE

  • All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurement carried out in the same conditions, or carried out with calibration compensation. ** Factory calibration uncertainty: ±0.88%RH; Temperature dependence: ±0.04 x (T-20) %RH (if T<15°C or T>25°C) *** On the basis of 1 measurement each 15 minutes at 25°C

6

TECHNICAL FEATURES

3.2 Housing
Dimensions Weight Display Control Material Protection PC communication Battery power supply Environmental conditions of use
3.3 Dimensions

100 x 42.5 x 15.9 mm
53 g
1-line LCD screen Dimensions of screen: 32 x 25.5 mm
1 OK key 1 Selection key
Compatible with food industry environment ABS housing
IP65: KT 120 IP20: KH 120
1 USB A male input
1 x CR2450 (button battery)
Air and neutral gases Humidity: in non condensing conditions Maximum altitude: 2000 m

3.4 Warranty period
KISTOCK data loggers have 1-year guarantee for any manufacturing defect (return to our After-sales service required).

TECHNICAL FEATURES

7

4 USE OF THE DEVICE

4.1 Display

END DATASET is finished

REC Indicates that one value is being recorded. It flashes: the DATASET did not start already.

FULL Flashing slowly: DATASET is between 80 and 90 % of the storage capacity. Flashing quickly: DATASET is between 90 and 100 % of the storage capacity. Constant: storage capacity full.
BAT Constant: indicates that the batteries have to be replaced.

Indicates the channel number which is measuring.
MIN The displayed values are the recorded MAX maximum/minimum values for the displayed channels.

Temperature in °C. Temperature in °F.

Indicates the alarm action type: rising or falling action.

Relative humidity (KH 120).

The values to display selected during configuration via the software will scroll on the screen every 3 seconds (only with the KH 120).
The display can be activated or deactivated via the KILOG software.
At extreme temperatures, the display can become hardly readable and its display speed can slow down at temperatures below 0°C. This has no incidence on the measurement accuracy.

4.2 Functions of keys
OK key: enables to start, stop the dataset (press during >3 seconds) or to change of scrolling group as described in the tables below.
Selection key: enables the scroll values in the scrolling group as described in the tables below.

Device Type of start/stop

state

selected

Start: by key

Key used

Action generated
Dataset starting

During 3 seconds

Stop: indifferent
Waiting Start by PC or for start date/hour

Inactive

Illustration
During 3 seconds

flashes Stop: indifferent

Inactive

Start: indifferent
Measurements scrolling (group 1)*
Stop: indifferent

  • Please see the summary table of the groups organization on page 10. ** Only with the KH 120.
    8

**
Or wait 3 seconds
USE OF THE DEVICE

Device Type of start/stop Key

state

selected

used

Action generated

Start: indifferent

Stop: by key

Dataset stop
During 3 seconds

Start: indifferent

Dataset in progress
REC

Group change (groups 2 and 3)*

Stop: indifferent Start: indifferent
Stop: indifferent

Groups scrolling (groups 1, 2 and 3)*

Indifferent
Dataset finished
END
Indifferent

Inactive
Measurements scrolling*

Illustration
During 3 seconds


Or wait 3 seconds

  • Please see the summary table of the groups organization on the following page. ** Only with the KH 120.

USE OF THE DEVICE

9

4.2.1 Groups organisation The table below summarises the groups organisation and measured values available during a measurement dataset.

Group 1 Measured temperature Measured hygrometry*

Group 2
Max. value in temperature Min. value in temperature
Max. value in hygrometry Min. value in hygrometry

Group 3
High alarm threshold in temperature Low alarm threshold in temperature
High alarm threshold in hygrometry Low alarm threshold in hygrometry

Press

key to change of group.

Press

key to scroll the values in the group.

4.3 Data logger configuration with the integrated PDF file
The class 120 KISTOCK data loggers have an integrated PDF file which allows to configure quickly and easily the data logger. Therefore, you can directly configure your data logger without opening the KILOG software.
Required configuration: to open this document, you need to use ONLY the “Adobe Acrobat Reader 9®” program (or higher), freely downloadable, which allows to read PDF format documents. Ensure you have installed it before starting.
Plug the class 120 KISTOCK data logger on an USB port of your computer**. The following window opens:

Click on “Open folder to view files”. Wait a few seconds (according to the dataset number of points), and a volume appears.
Double-click on the “Configuration…” PDF file

  • Only with the KH 120. ** The computer must be in compliance with the IEC60950 standard.
    10

USE OF THE DEVICE

The integrated configuration file opens:
The file header indicates the device name and serial number. Button which allows to load a previous configuration, saved before on the computer.
“General information” Displays the name of the dataset and the possible comments.
“Configuration” allows to configure: – The datalogger – The recording mode – The stop conditions of the record
“Channel parameters” allows to configure the channels of temperature (KT 120 and KH 120) and hygrometry (only with the KH 120).
· Choose the language Select the required language:
· Choose the date format Select the required date format:
· General information Dataset name: this field allows to name the dataset. Comments: this field allows to write comments on dataset.

USE OF THE DEVICE

11

· Configuration Recorder Active screen: tick “Yes” to activate the screen display or “No” to deactivate it. Management DST: for an automatic management of DST, tick “Yes” or tick “No” to deactivate it. If you choose “Yes”, the “Next time change” fields become accessible. Dates and times of the next time change are proposed by default. You can modify them: click on the “Date” field then on to display the calendar. Click on the required date. Click on the “Hour” field to modify the time on which the next time change will be applied: the time format is 00:00. On the last field, click on and choose “+1h” to add an hour or “-1h” to subtract an hour. The date and time change will be applied on the required date and time and will add or subtract an hour.
Recording Interval: in the “Interval” field, inform the required interval duration between two measurements, then select the unit (minutes or hours). Start type – Tick “Button” for a start type by button. – Tick “Date” for a start type by date: inform the required date and time of the start. Click on the “Start date” field then click on to display the calendar and select the required date, or write it manually, with respect to the date format selected previously.
Stop conditions Stop type Select the required stop type:

– The stop by date is available only if the start type by date has been chosen previously. If you choose “Date”, inform the required stop date and time in the “Stop date” field: click on to display the calendar then select the required date, or write it manually with respect to the date format selected previously. – The stop by duration allows to determine a recording duration: inform the “Days” and “Hours” fields. – The stop by number of items allows to determine a required number of measurement before the dataset stops. Inform the “Number of items” field (between 1 and 50 000 points). – “Total memory” allows to record continuously up to 50 000 points before the dataset stops. – “Loop” allows to record the values continuously and once the memory capacity reached, the last recorded values overwrite the first. – “Stop by button”: tick “Yes” to allow a stop by button. Therefore, push the data logger OK key during 3 seconds to stop the measurement dataset. To not allow it, tick “No”. The stop by button can not be deactivated if the chosen stop condition is “Loop”, “Total memory” or “Number of points”.
Channel parameters Temperature (KT 120 and KH 120) and humidity (only the KH 120) – Choose the temperature measurement unit: tick the “°C” or “°F” box. – Active channel: tick “Yes” to activate the channel or “No” to deactivate it. – Active alarm: tick “Yes” to activate the alarm or “No” to deactivate it.
If the alarm is activated, inform the “High” and “Low” fields to configure the alarm threshold. Inform the “Delay” field in number of points. According to the measurement interval previously configured, the duration is automatically actualised.

12

USE OF THE DEVICE

For example: if an interval of 1 minute has been configured and that the delay in number of points for the high threshold is 5, the delay duration will be 5 minutes.

When the configuration is finished, click on the validate.

button to

Chose the place to save the configuration: to use this configuration for the next dataset, save the configuration directly on the data logger on “Removable disk”.

Check that the dataset is finished to ensure the new configuration is taken into account.

A message asks you to overwrite the existing file. Click on “Yes”.

To use this configuration later for another dataset, or to configure another device, you can save it on the required

location. To recover it later, click on the

button on top of the page, then

select the required file on “.xdp” format, click on the

button to use it for the next dataset.

4.4 Data logger download with PDF report edition
Plug the class 120 KISTOCK data logger on an USB plug of the computer*.
Wait a few seconds, then the following window opens:
Click on “Open folder to view files”. The windows explorer opens.
Double-click on the “Report” PDF file to visualise the dataset report.

  • The computer must be in compliance with the IEC60950 standard.

USE OF THE DEVICE

13

Example of report:
State indicators: : Alarm activated : Alarm deactivated : Alarm OK : Alarm triggered
The background information indicates the dataset name and the eventual comments.
The device configuration is summarised with the measurement interval, the start/stop type, the recording duration, the number of recorded values and the date and time of dataset start and end.
The chart allows to visualise the recorded values evolution, with the units on ordinate, the date and time on abscissa and the defined high and low thresholds.

The header indicates the date and time of the report edition Device references Serial number and firmware version
The channel statistics indicate the values unit and the minimal, maximal, average and MKT values.
The alarms parameters and results indicate the defined high and low thresholds, their state (alarm or OK) and the longest duration of threshold exceeding.

You can print it or export it in PDF format to integrate it easily to your documents.
In “Loop” mode, results displayed on “Device configuration”, “Channel statistics” and “Alarms parameters and results” parts correspond to the device configuration, to the statistics and to the alarms parameters and results recorded since the launching of the measurement dataset. Data indicated on the graph correspond to the results of the last recorded loop.
4.5 Configuration, data logger download and data processing with the KILOG software
Please see the KILOG software user manual: “KILOG-classes-50-120-220-320”.

14

USE OF THE DEVICE

5.1 Replace the battery

5 DEVICE MAINTENANCE

With 500 days to 3 years* battery life, KISTOCK guarantees long-term measurement.

To replace the battery:

1. Unlock the battery hatch with a screwdriver or a coin. 2. Turn towards the left until the marker aligns in front of the opened padlock symbol. 3. Continue to turn until the hatch rises. 4. Remove the battery from its compartment. 5. Press “Select” and “OK” keys in succession until the KISTOCK display is blank. 6. Replace the battery (button battery CR 2450**) in such a way the + pole will be visible.

1

2

3

Button battery CR 2450 4

To unlock correctly the battery hatch, continue to turn after the opened padlock
symbol. The battery hatch rises.

Locking indicator of the battery hatch

Battery hatch

Replace the battery hatch with the indicator in front of the opened padlock and close it by turning it towards the right in order to make correspond the indicator with the closed padlock.

Only use trademark or high quality batteries in order to guarantee the announced autonomy.

After the battery replacement, the device must be reconfigured.

5.2 Device cleaning
Please avoid any aggressive solvent. Please protect the device from any cleaning produce containing formalin, that may be used for cleaning rooms and ducts.

  • On the basis of 1 measurement each 15 minutes at 25°C ** The battery must be in compliance with the 60086-4 standard.

DEVICE MAINTENANCE

15

6 CALIBRATION
All the KISTOCK devices have an integrated adjustment certificate in the memory in PDF format which can be visualized and printed easily. A calibration certificate is available as option in paper format. We recommend to carry out a yearly checking.

7 ACCESSORIES

Accessories

Part numbers Illustrations

1 button battery CR2450

KBL-2450

KILOG Lite Free software to download on the Sauermann website sauermanngroup.com Allows the data download (graphics and points statement) and the data logger configuration.
KILOG software KILOG software enables to configure, save and process your data in a very simple way.

KILOG-LITE KILOG-3-N

Calibration certificate

25 mm diameter metal washer with double sided adhesive tape

KRM

Only the accessories supplied with the device must be used.

8 TROUBLESHOOTING

Problem “hi” or “lo” is displayed.

Probable cause and possible solution
The measuring range is exceeded, if the problem persists please proceed to a factory return of the device.

No value is displayed, only the icons are present.

The display is set “OFF”. Set it on “ON” with the KILOG software (see page 14).

The display is completely off and there is no communication with the computer.
“Err.” is displayed.
“Er. 1” is displayed.

The battery must be replaced (see page 15).
Error during the device update (reading or writing error in the flash memory of the micro-controller). Remove the battery from the device. Carry out a long press on the “Selection” key. Put the battery back. A count is displayed. Press “OK” before the end of the count. The bootloader version is displayed then “—“. Connect the device to the computer and launch the update procedure (see the software user manual, chapter “Update the device”).
Temperature measurement error. Please proceed to a factory return of the device.

16

TROUBLESHOOTING

TROUBLESHOOTING

17

BE CAREFUL! Material damages can happen, so please apply the precautionary measures indicated.
sauermanngroup.com

NT_Kistock KT120 – KH120_EN ­ 12/07/23 ­ Non-contractual document ­ We reserve the right to modify the characteristics of our products without prior notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

sauermann User Manuals

Related Manuals