sauermann SI-CA 130 Versatile Analyser with Touch-Screen Display User Guide
- June 3, 2024
- sauermann
Table of Contents
- SI-CA 130 Versatile Analyser with Touch-Screen Display
- Before Using the Flue Gas Analyzer
- Analyzers description
- **Operating temperature, protection of the instruments and information
- First start-up
- ON / OFF
- Stop / Restart the Pump
- Combustion Analysis, Saving & Printing
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SI-CA 130 / SI-CA 230
Quick Start Guide
www.sauermanngroup.com
SI-CA 130 Versatile Analyser with Touch-Screen Display
Quick start guide
- **** These operating instructions describe the basic handling of the device.
- Please refer to the operating instructions available at www.sauermanngroup.com for safe use of the product and detailed information.
- Do not give this device to a child.
- The magnets in the back of the instrument can damage credit cards, hard drives, mechanical watches, pacemakers, defibrillators and other devices proven sensitive to magnetic fields. It is recommended to keep the instrument at a distance of at least 25 cm (10”) away from any of these devices.
- These gas analyzers are designed to measure flue gases exhausting from combustion equipment. They are not designed for continuous operations and/or use as a control/alarm system
The Si-CA 130 and Si-CA 230 analyzers are touchscreen devices with just the on/off button:
Before Using the Flue Gas Analyzer
WARNING!
- Be sure all connections are tight to assure accurate sampling.
- When conducting measurements, the water trap/filter assembly MUST be in a VERTICAL position.
**** When testing is completed, always drain any accumulated condensation
inside the water trap (after EVERY test!).
The condensate be slightly acidic, so avoid contact with skin and make sure
condensate does not leak out of water trap.
Analyzers description
- Min-DIN connection for CO and CO2 probe
- Thermocouple connection for air temperature
- Thermocouple connection for flue gas temperature
- P- connection
- P+ connection
- Gas connection
- USB connection
**Operating temperature, protection of the instruments and information
about storage**
- Operating temperature: from -5 to 45 °C (23 to 113 °F)
- Protection: IP42
If the instrument is stored outside the operating temperature (for example in a van, a warehouse,…) please let the analyzer acclimate to room temperature for at least 15 minutes before starting and operating the analyzer.
If the ambient temperature is lower than 10 °C (50 °F), the analyzer should be acclimated to ambient temperature before performing measurements.
First start-up
DO NOT insert the gas probe in the flue/chimney/stack.
Keep pressed for 3 seconds to turn on the analyzer.
|
---|---
The probe can be inserted in the chimneyThe analyzer displays the measurements.
ON / OFF
During autozero DO NOT insert the gas probe in the chimney. Keep
pressed for 3 seconds to turn on the analyzer.
Once the autozero is finished, insert the gas probe in the chimney and gas
measurments are displayed.
Keep ****pressed for 3 seconds to turn off the analyzer.
Before powering off, disconnect hoses from the analyzer and empty and dry the
water trap.
Stop / Restart the Pump
It is possible to turn off the pump during a gas analysis.
Tap . Pump is off and values are on hold.
Tap . Pump is on and measurements re-start.
Combustion Analysis, Saving & Printing
**** Before proceeding with the combustion analysis, remember to set the proper fuel.![sauermann SI CA 130 Versatile Analyser with Touch Screen Display
- fig10](https://manuals.plus/wp-content/uploads/2022/12/sauermann-SI-CA-130 -Versatile-Analyser-with-Touch-Screen-Display-fig10.png)
You can also quickly access the fuel selection menu via the fuel shown at the top of the combustion gas analysis screen
- To view the different measured parameters, just scroll the screen.
- To save combustion data, first tap on the Save icon then select or create a folder and tap on Save. The Sauermann Combustion mobile phone app and/or PC software can also be used to save data.
- To prints the results, use the Wireless Printer avalaible as option.
The Sauermann Combustion app lets you control your Si-CA analyzer remotely, view measurement results in real time, and customise them before exporting in the format of your choice.
http://qrcode.inair.cloud/sauermann/sauermann_combustion
Software & Appshttps://sauermanngroup.com/en-INT/resource-
center/softwares
Download the Sauermann Combustion Apphttps://sauermanngroup.com/
Download the Sauermann Combustion Softwarehttps://sauermanngroup.com/en-INT/resource-
center/softwares
Download the full manual
Customer service portal / Portail service clients
QSG
– Commercial, Industrial & HVAC Analyzers 2021Si-CA130-230_07/10/22
– Non-contractual document
– We reserve the right to modify the characteristics of our products without
prior notice.www.sauermanngroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>