KNOW YOUR DEVICE
FRONT
Al. Channel Selection
A2. Outdoor Sensor Low Battery Icon
A3. Max/Min Icon
A4. Calibrated Icon
A5. Indoor Temperature Values
A6. Indoor Temperature Trend
A7. Outdoor Temperature Trend
AS. Outdoor Temperature Values
A9. Record Time Icon
A10. Outdoor Humidity Trend
A11. Outdoor Humidity Values
A12. Indoor Humidity Level
A13. Indoor Humidity Trend
A14. Indoor Humidity Values
TOP
A15. Backlight
Touch button to temporarily activate the backlight.
BACK
Bl. Integrated Hanger Opening
B2. SET Button
B3. +/MEM Button
B4. -/ CH Button
BS. Battery Compartment
B6. Magnetic Attachments
B7. °C/°F Button
BS. Table Stand
Table Stand
Wireless Remote Sensor
C1: LCD display – Temperature
C2: LCD display – Humidity
C3: Transmit signal LED
C4: “°C/°F” button
C5: “TX” button
For sending out signals manually.
C6: “CHANNEL 1 or 2 or 3” switch
C7: Battery compartment
SPECIFICATIONS
- Indoor/outdoor humidity and temperature monitor
- Alternating 24-hour & all-time settings
- Backlight function
- Humidity measurable range: 1%RH ~99%RH
- Humidity accuracy: ±2%RH
- Temperature:
- Indoor measurement range: -9.9°C (14.2°F) ~ +S0.0°C (122.0°F)
- Outdoor measurement range: -40°C (-40°F) ~+70.0°C (158.0°F)
- Switchable between °For °C
- Temperature accuracy: ±0.5 °F
- Minimum/maximum display for humidity and temperature
- Humidity level indicator
- Wireless remote sensor
- 3 channels available
- Built-in wall mount, table stand and magnets
- 200ft transmission range in open areas
- • Battery Powered:
Main monitor: 2xAAA 1.SV
Wireless remote sensor: 2xAA 1.SV
Note:
Different batteries have different temperature limits. The wireless remote
sensor can work at -40°C to 70°C, please choose the right battery depending on
your needs.
Alkaline zinc manganese batteries work at -20°C to 60°C. Polymer lithium ion
rechargeable batteries work at -40°C to 70°C.
The wireless remote sensor is not waterproof. You should avoid leaving the
sensor out in rain or under direct sunlight.
COMPONENTS
- Humidity and temperature monitor *1
- Instruction manual *1
- Wireless remote sensor *1
SET UP
Install or Replace Batteries
Batteries must be installed for the main monitor and remote sensor to work.
Main monitor
- Slide off the battery cover of the main monitor.
- Insert 2x AAA batteries and ensure that poles [“+”and “-“] are correct.
- Close battery cover.
- Main monitor will automatically start in normal mode.
Wireless remote sensor
- Slide off battery cover from wireless remote sensor.
- Insert 2xAA batteries and ensure that poles [“+”and “-“] are correct.
- Select channel through the “l 2 3” knobs for wireless remote sensor.
- The indicator will light up once to indicate that the detected temperature and humidity have been transmitted by wireless remote sensor.
- Close battery compartment.
Synchronize remote sensors with main monitor
- Place the remote sensor near main monitor.
- Once batteries are installed in main monitor, the RF signal icon 1ocated on the upper left side of the display will flash for 3 minutes. This indicates that the main unit is in synchronization mode and waiting for the remote sensor to connect.
- If the RF signal icon stops flashing after 3 minutes, press and hold “-/CH” button for 2 seconds until the RF signal flashing again to set the main unit back in synchronization mode.
- Press” -/CH” button on the main monitor to select CH1, CH2, CH3, or CH1- CH3 (auto-alternating display from CH1 to CH3 every 5 seconds with icon displaying on the upper left side of the display).
- Install batteries for the remote sensor and select channel with numbered knobs (1, 2, and 3) to select CH1, CH2, or CH3.
- Ensure that main monitor and remote sensor are on the same channel. When the main monitor successfully receives signals from remote sensor, the temperature and humidity detected by the remote sensor will show on the main monitor LCD display.
- The main monitor can connect up to 3 remote sensors at the same time. If multiple sensors are used simultaneously, please repeat above steps after installing batteries to connect other remote sensors, make sure these sensors on different channels. Press ” -/CH” button on the main monitor to view the readings of each channel.
- If the main monitor fails to synchronize with the remote sensor on any channel. Adjust the main monitor to the corresponding channel, press and hold “-/CH” button for 2 seconds to search signals for the remote sensor. Press “TX” button inside the battery bay of the corresponding remote sensor to send out signals manually.
Toggle Fahrenheit or Celsius
To select Fahrenheit or Celsius, press “°C/°F ” button located on the back of the monitor.
Placement for Maximum Accuracy
The main monitor is equipped with a high-performance sensor. Because this device is sensitive to surrounding environment conditions, it is important to place the monitor in an ideal spot for the most accurate readings. Place the monitor in a dry area free of dirt and dust, out of direct sunlight, and away from heats sources or vents. To ensure accurate humidity measurement, place monitor away from humidity sources. The wireless remote sensor is not waterproof and should also avoid prolonged contact with direct sunlight. You can place it under a covering to avoid both rain and sun.
USING YOUR DEVICE
Maximum and Minimum Records
-
The SC92 displays maximum and minimum records for both temperature and humidity.
-
“24hr” refers to maximum and minimum readings from the last 24 hours.
-
“All-time” refers to maximum and minimum readings since batteries were installed.
-
Press “+/MEM” button in normal mode to enter 24hr or All-time mode.
-
Press “-/CH” button to choose the channel to display on the monitor.
Options: CH1, CH2, CH3, and CH1-CH3 (auto-alternating display from CH1 to CH3 every 5 seconds). -
Press and hold “+/MEM” button to manually clear the maximum and minimum records currently being viewed. Dashes will display to confirm that you have cleared the records. Note: Records will be erased if batteries are removed.
Backlight
Touch or press any button to temporarily activate the backlight for 10
seconds.
Note: The backlight can’t be set to be on permanently.
Calibration
Calibration can improve accuracy when product placement or environmental factors impact your data accuracy.
As part of the calibration process, you will calibrate the monitor and each connected channel sequentially, the steps for which are outlined below. To exit calibration mode at any point and save your adjustments, leave the monitor for 10 seconds.
Note:
This product has passed professional testing and calibration. No extra
calibration is required before use.
Calibrations will be erased if the batteries are removed. Adjustments below are relative to temperature and humidity readings currently viewed. Humidity adjustable range: ±9%RH Temperature adjustable range: ± S.4″F (±3″C)
- To access calibration mode, press and hold “SET” button for 3 seconds. Indoor temperature display flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the temperature for the indoor display.
- Press “SET” button to confirm. Indoor humidity display flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the humidity for the indoor display.
- Press “SET” button to confirm. Outdoor temperature display of channel 1 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the temperature for the outdoor display.
- Press “SET” button to confirm. Outdoor humidity display of channel 1 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the humidity for the outdoor display.
- Press “SET” button to confirm. Outdoor temperature display of channel 2 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the temperature for the outdoor display.
- Press “SET” button to confirm. Outdoor humidity display of channel 2 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the humidity for the outdoor display.
- Press “SET” button to confirm. Outdoor temperature display of channel 3 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the temperature for the outdoor display.
- Press “SET” button to confirm. Outdoor humidity display of channel 3 flashes.
- Press “+/MEM” or “-/CH” button to increase or decrease the humidity for the outdoor display.
- Press “SET” button to confirm.
- Main monitor will automatically enter into normal service mode.
Note:
- The display will save the adjustments and exit calibration mode after 10 seconds of inactivity.
- The calibration process will finish after you have completed the calibration of all connected channels.
- Calibrations will be erased if the batteries are removed.
TROUBLESHOOTING
After-sales Support
If your device fails to work or you are less than completely satisfied with
this product in any way, please don’t hesitate to contact us.
For further support and discount information, join our Facebook group or
follow us on Instagram.
support@smartro.co
http://bit.ly/smartro_Ol
https://www.instagram.com/smartro_01/
Website: https://www.smartro.co/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>