CDP R-UPR508 Interactive Con Regulador 500va 250W User Guide

June 6, 2024
CDP

CDP R-UPR508 Interactive Con Regulador 500va 250W

IMPORTANT SAFETY

This manual contains important safety instructions. Please read and follow all instructions carefully during the installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

CAUTION:
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)

CAUTION:
 To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.

CAUTION:
Do not attach non-computer-related items, such as medical equipment, life­support equipment, microwave ovens, or vacuum cleaners to UPS.

CAUTION:
Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.

CAUTION:
In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.

CAUTION:
Unplug the UPS prior to cleaning and do not use liquid or spray detergent. CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

CAUTION:
The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.

CAUTION:
The internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. CAUTION! When replacing the batteries, use the same number and type of batteries. CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.

INSTALLING YOUR UPS

The box should contain the following:

  1.  UPS Unit x1;
  2.  User Manual x 1;

OVERVIEW

The UPS provides automatic voltage regulation for inconsistent utility power, and provides battery backup during power outages, and ensures consistent power to your computer system.

HARDWARE INSTALLATION GUIDE
 Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off positions. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive), etc. into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or another large

  1. Electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  2.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.
  3.  Press the power switch to turn the unit on. The power-on indicator light will illuminate and the unit will “beep”.
  4. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker/ fuse is normal and then turn the UPS on.
  5. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times
  6. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.

BASIC OPERATION

Front panel

  1.   Power Switch
    Press the switch for 2 seconds to turn the UPS ON or OFF. Sound disable: The audible alarm can be turned OFF or ON by quickly pressing the power switch twice. The default setting is for the Alarm On.

  2. Led Indicators
    This LED is illuminated when the UPS is working .

Rear panel

  1. Input Circuit Breaker
    The circuit breaker provides optimal overload protection.

  2. Site Fault LED Indication
    The red LED is lighting when input power polarity incorrect. Ground fault reversed polarity. (These two faults void the warranty)

  3.   Battery Backup & Surge Protected Outlets
    Provide battery backup and surge protection. They ensure power is provided to connected equipment Over a period of time during a power failure.

  4. Surge Only Protected Outlets
    Provide surge protection for bypass output.

  5. Input power cord
    Connect to utility power.

LED INDICATION

TECHNICAL

TROUBLE

Enter this link to register your product.

Read User Manual Online (PDF format)