CDP UPO33-HM3AX Chicago Digital Power User Manual

June 9, 2024
CDP

CDP UPO33-HM3AX Chicago Digital Power

Feature

  • True double-conversion
  • SP technology guarantees high performance
  • 1O” LCD for comprehensive UPS information
  • Active power factor correction
  • 5OHz/6OHz frequency converter mode
  • ECO mode operation for energy saving [ECO]
  • Emergency power off function [EPO]
  • Generator compatible
  • SNMP+USB multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Maintenance bypass available

Specification


PHASE| 3-phase in/3-phase out
CABINET CAPACITY| 60KW
BATTERY TYPE| Built in Battery
ONE POWER MODULE CAPACITY| 20KVA/20KW
MAX. POWER MODULE NO.| 3 x 20kVA
MAX. BATTERY SET NO| 120 pcs (12 Trays)
|
Voltage| 3 x 120 VAC (Ph+N)
Voltage Range| 156-253 VACat 100% load, 121 -155 VACat 70%load
Frequency Range| 40Hz-70Hz
Power Factor I| ea 0.99 @ 100% load
Output Voltage| 3 x 120 VAC (Ph+N)
AC Voltage Regulation (Batt. Mode)| ±1%
Frequency Range (Synchronized Range)| 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)| 50 Hz± 0.1 Hzor60 Hz± 0.1Hz
Current Crest Ratio| 3:1(max.)
Harmonic Distortion| as 1.5 % THD (Linear Load)
as 4 % THD (Non-linear Load)


Transfer Time

I

| AC  mode to Battery mode| zero
Inverter to Bypass| zero
Waveform (Batt. Mode)| Pure Sine Wave
Overload              I AC  Mode| 110% for 1 hr, 125% for 10 min, 150% to 1 min, >150% for200 ms
EFFICIENCY| Up to 96%
Nominal Voltage| 240 with neutral +/-120V (12V x20 pcs)
Float Charging Voltage| 2.25V /Cel
Boost Charging Voltage| 2.35V I Cel
Temperature Compensation| Yes
Maximun Charging Current| 8A for each power module (user adjustable)
| |
LCD Panel| | UPS status, load level, battery level, inpuVoutput voltage, backup time and fault conditions
ALARM| |
Battery Mode| | Sounding every 4 seconds
Low Battery| | Sounding every second
Overload| | Sounding twice every second
Fault| | Continuously sounding
Cabinet Dimension (mm)| 1100 X 600 X 1475 (DX W X H)
Net Weight (kgs)| 675
|
Operation Temperture| 0-40°C
Operation Humidity| <95% and non-condersing
IP CLASS| IP 20
|
SmartUSB| | Supports Windows® 2000/2003/XPNista/2008, Windows® 7/8, Linux and MAC
Optional SNMP| | Power management from SNMP manager and web browser
| |
Safety| | UL 1778 / CSA C22 / NO 107, 3 -05
EMC| | FCC PART 15, SUPPORT B class A

*Wthe UPS is installed or used in a place where the altitude is above than 3000m, the output power must be derated 1% per 100m

Specifications are subject to change without notice

CDPCHINA
china@cdpups.com

DPCOSTARICA
costarica@cdpups.com

CDPVENEZUELA
venezuela@cdpups.com  

CDP COLOMBIA
colombia@cdpups.com

CDPHONGKONG..
hongkong@cdpups.com

CDPMEXICO
mexico@cdpups.com

CDPPERU
peru@cdpups.com 

CDPUSA
usa@cdpups.com

CDP GUATEMALA
guatemala@cdpups.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals