Use and Care Guide
Thank you for choosing the Commercial Electric LED Motion Sensing Color
Changing Wrap Light. Please read the following instructions carefully before
installing and using the product.
Safety Information
- Always turn off the power supply at the fuse or circuit breaker box before installing the fixture.
- Ground the fixture to avoid electric shocks and ensure reliable starting.
- Double-check all connections to ensure they are tight and correct.
- Wear rubber-soled shoes and work on a sturdy wooden ladder.
- Account for small parts and dispose of packing materials properly to avoid hazards for children.
- This fixture should be used in a circuit protected by a fuse or circuit breaker and installed according to local electrical codes.
- If you are unsure about your wiring, consult a qualified electrician or local electrical inspector.
Warnings
- Risk of shock : Handle house electric current properly to avoid painful shock or serious injury.
- Turn off the main power at the circuit breaker before installing the fixture to prevent possible shock.
- All electrical connections must comply with local and National Electrical Code (N.E.C.) standards.
- If you are unfamiliar with proper electrical wiring connections, seek the assistance of a qualified electrician.
- Ensure a cumulative leakage current of less than 3.5mA on the 0-10V control circuit.
- The voltage of the 0-10V dimmer wire should not be less than 300Vac.
THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric
through the purchase of this LED Motion Sensing Colour Changing Wrap Light. We
strive to continually create quality products designed to enhance your home.
Visit us online to see our full line
of products available for your home improvement needs. Thank you for choosing
Commercial Electric!
Safety Information
For your safety, always remember to:
- Turn off the power supply at the fuse or circuit breaker box before you install the fixture.
- Ground the fixture to avoid potential electric shocks and to ensure reliable starting.
- Double-check all connections to be sure they are tight and correct.
- Wear rubber soled shoes and work on a sturdy wooden ladder.
- Account for small parts and destroy packing material, as these may be hazardous to children.
This fixture is designed for use in a circuit protected by a fuse or circuit breaker. It is also designed to be installed in accordance with local electrical codes. If you are unsure about your wiring, consult a qualified electrician or local electrical inspector, and check your local electrical code.
-
WARNING : RISK OF SHOCK. House electric current can cause painful shock or serious injury unless handled properly.
-
CAUTION : Turn off the main power at the circuit breaker before installing the fixture, in order to prevent possible shock.
-
NOTICE : All electrical connections must be in accordance with local and National Electrical Code (N.E.C.) standards. If you are unfamiliar with proper electrical wiring connections obtain the services of a qualified electrician.
-
Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions.
-
WARNING : The 0-10V control circuit is intended for connection to an external Class 2 supply.
-
WARNING : Please assure a cumulative leakage current of less than 3.5mA on the 0-10V control circuit.
-
WARNING : The voltage of 0-10V dimmer wire can not be less than 300Vac.
Warranty
LIMITED WARRANTY
This product is warranted to be free from defects in workmanship and materials
for up to 5 years from date of purchase. If it fails to do so, please contact
the Customer Service Team at
1-877-527-0313 or visit
www.HomeDepot.ca.
Pre-Installation
TOOLS REQUIRED
Part | Description | Quantity |
---|---|---|
A | Diffuser | 1 |
B | Housing | 1 |
HARDWARE INCLUDED
Installation
Preparing to mount housing to the ceiling
- Turn OFF the main power at the circuit breaker before the installation.
- Locate the electric power supply junction box that is being used for this installation.
- Ensure that the center knock out on the housing (B) will be aligned with the junction box.
- Mark 2 screw hole locations on the ceiling, 41 5/8in. apart. Drill two holes in the ceiling at the marked locations. Install an anchor (AA) in each of the drilled mounting holes.
- Insert screw (BB) through gasket (CC), tighten each screw leaving a small distance (1/2in.) away from the ceiling.
Removing the diffuser from the housing
- Press down on the end of the diffuser (A) opposite of the end cap with the motion sensor.
- There is a tab that the diffuser has to slide underneath to allow it to be removed.
- Slide the diffuser (A) toward the end being pressed down opposite the end cap with the motion sensor. Lift the diffuser (A) from the side with the motion sensor to remove the diffuser.
Accessing the Wires
- Once the diffuser is removed, disconnect the sensor terminal as shown bleow. Figure 1.
- Locate the metal terminal cover split into two parts in the middle of the housing. Figure 2.
- Start by removing the metal cover on the opposite side of the motion sensor that covers the LED Driver, by pushing down and pulling it apart from the center, then lift on the end closest to the end cap. Repeat this step on the remaining cover. Figure 3. For direct wire connection, before connecting to the power supply wires, insert the two extension wires: Black – L wire (EE) and White – N wires (FF) into the 2 pin terminal located in the middle of the housing. Figure 4.
Selecting the CCT and Lumens
- This product includes the feature to select the color temperature (CCT) and brightness level (lumens) at the point of installation. Locate the CCT switch on the side of the housing. Move the switch to the desired CCT: 3000K (warm white), 4000K (cool white), or 5000K (daylight).
- Locate the lumen select switch on the side of the housing. Move the switch to the desired lumen selection: 4500, 6000, or 7500 lumens.
Installing the housing
- Please ensure to turn OFF the main power at the circuit breaker before connecting the wires.
- Place a screwdriver on center of slot and gently strike with hammer to remove the knock out cover from the center of the housing. Locate the two key holes on the housing on each end.
- Place one side of the housing key hole on the mounting screw previously installed on the ceiling from step 1. Repeat with the other side.
- Slide the housing in place until it is secure.
- Feed the electric power supply wires through the knock out hole.
- Tighten the mounting screws to secure the housing to the ceiling.
Connecting the wires
- Identify the wiring located inside of the housing: (black – line voltage, white – neutral, green – ground, and 0-10V dimming wires, purple – Dim (+) and pink – Dim (-) Figure 1.
- Feed the wires from the housing through the center knock out and.
- Connect the Black (L), White (N) and Green (G) wires from the fixture to their corresponding wires from the junction box using Wire Nuts (DD).
- If a 0-10v dimming circuit is available, using a wire cutter splice the purple and pink wires to expose the wiring.
- Connect the purple and pink wires from the fixture to the same color wires in the electrical box.
- If 0-10v dimming is not desired, wrap the ends of the purple and pink wires with electrical tape (not included) to cover the wire. Position the connected wires back into the junction box.
NOTE : If the sensor terminal is disconnected, connect the two ends together to have full operation of the motion sensor. Figure 2.
Installing the diffuser
- Reinstall the 2 metal terminal covers removed in step 3 to the housing over the wires.
- Ensure the metal covers are snapped in place.
- Reinstall the diffuser to the housing by inserting one side into the end cap opposite of the motion sensor until it can no longer slide in that direction.
- Then slide the diffuser in the opposite direction to tightly secure in place.
- Restore power to the electrical box.
- Turn on the light switch to activate the fixture.
NOTE : Be careful not to pinch wires while reinstalling the metal covers.
Linking feature
- Follow above all steps for one fixture to receive direct wire power. Only follow the step 1,2,4,7 to install other linkable fixtures to receive power through the linking cable.
- Remove the silicone stopper from the side of the housing.
- Utilize the linkable wire (GG) to connect Fixture 1 motion sensor end cap side to Fixture 2 end cap without the motion sensor side. Connect the female connector (square) side of the linkable wire (GG) to the male silicone stopper (square) side of the Fixture 1. Figure 1. Then plug in the male connector of linkable wire (GG) and into the female silicone stopper side of the Fixture 2. Figure 2.
NOTE : Maximum 6 units can be linked. Maintain a distance of 5in.
- 10in. distance between units while linked.
Motion Sensor Operation
- After turning on the fixture for the first time, the motion sensor will activate by triggering the light to come on 3-5 seconds and then turn off. If motion is detected at this time, the light will remain on.
- Motion Sensor Override, if the motion sensor is not needed, the sensor can be deactivated by disconnecting the sensor terminal as shown below. Ensure the power is turned off before removing sensor terminal.
Dimmer Compatibility
- Lutron : NTSTV-DV-WH, DVSCTV-SW.
- Leviton : DS710-10Z, IP710-DLZ, IP710-LPZ.
- Eaton : DF10P-C1, SF10P – W.
Care & Cleaning
CAUTION : Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from the fuse box.
- Clean the fixture with a soft, dry cloth.
- Do not use cleaners with chemicals, solvents, or harsh abrasives.
Troubleshooting
WARNING : Before doing any work on the fixture, disconnect power to the light fixture by turning the breaker off or removing the fuse from the fuse box.
Troubleshooting
Problem| Possible cause|
Solutions
---|---|---
The light cannot be turned on.| The power is off.| Ensure the power supply is
on.
The circuit breaker is off.| Ensure the circuit breaker is in the on position.
A wire is not properly connected.| Check to ensure proper wire connections
are made. Contact a qualified electrician.
The switch is defective.| Contact a qualified electrician.
The fuse is blown or circuit breaker is tripped when turning on the light.|
The wires are crossed or the power wire is ground out.| Check the wire
connections. Contact a qualified electrician or call
Commercial Electric customer service at 1-877-527-0313.
Light Distribution
Input Volts (AC)
| Input Frequency (Hz)|
Input Watts (W)
---|---|---
120-277V| 60| 39/53/62W
Questions, problems, missing parts? Before
returning to the store, call Commercial Electric Customer Service
8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m., EST, Saturday
1-877-527-0313
HOMEDEPOT.CA
Retain this manual for future use.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>