CDP R-UPR 508 Interactive UPS User Manual
- June 17, 2024
- CDP
Table of Contents
CDP R-UPR 508 Interactive UPS
R-UPR
- Thank you for selecting this No-break (UPS) system.
- Offers perfect protection for your equipment.
- This manual is an installation and use guide.
- If a problem occurs with the system, please refer to this user manual before calling the Service Center.
Presentation
- The R-UPR series is a line interactive No-break (UPS).
- When the electric flow is normal, the UPS protects against over tension, while using the energy to recharge the internal battery.
- In situations where the flow presents electrical problems, the UPS is capable of supplying immediate alternate current to the connected devices.
Features
- Powerful controls based on microprocessors for higher reliability with automatic regulation.
- Designed to provide, years of protection for your devices and peripherals.
- High-level battery charger to extend their longevity and recharge completely
- Overload protection during operation and backup mode
- Can turn it on without plugging in
Condition Panel
- LED indicators
- Cold start / Main button
- AVR/UPS outlets
- Protection breaker
- Surge suppression outlets
- AC power cord
Installation and Operation
- Check the UPS when received. The packaging is recyclable, keep it to reuse or dispose of it correctly
- The power cord at the back panel must be connected to a wall outlet, please remember that the voltage must be the same as the UPS. If the UPS is 220v, the wall outlet must be 220v
- The power cord of your devices (as a computer) must be connected to the outlets on the back panel
- While the UPS is connected to the electrical fluid, press the main button for 3 seconds
- Connect the devices, such as a computer or a monitor, directly to the back panel outlets of the UPS
- Turning off the UPS: Press the main button of the UPS for 3 seconds. The UPS will turn off.
Warning!
- The maximum consumption, must not exceed 100% of the rated power, depending on the model
- Press the main button of the UPS for 3 seconds; the green LED will turn on to indicate normal operation
- If the UPS has not been used during a period longer than 3 months, should be connected to the wall outlet for a minimum of 6 hours to recharge the battery, before use.
- This model cannot be adapted to an external battery for longer use
- This UPS will supply clean energy while is plugged into an AC outlet
- When the UPS is connected, the battery will charge automatically without pressing the main button. Due to this is normal that the temperature of the UPS increase.
- (Designed to use with computers. Not recommended for lineal loads)
Indicators Definition
Backup Mode | Status | Red LED | Blue LED | Sound |
---|---|---|---|---|
Normal Battery (Normal load) | 2 blinks every 4 seconds | Off | 2 beeps every 8 |
seconds
No Load
(only works for green mode
| 1 blink every 4 seconds| Off| 1 beep every 8 seconds
Overload
I120% of the load)
| 2 blinks every 4 seconds| ****
Off
| Continuous beep
Temperature Exceeded| 32 blinks every 2 seconds| ****
Off
| Depends of the load
Short Circuit| 32 blinks every 2 seconds| Off| 32 beeps every 2 seconds
Low Battery| 4 blinks every second| Off| 4 beeps every second
External Battery| 8 continuous blinks every second| Off| 8 continuous beeps
every second
Phase Blocked| Off| 4 blinks every second| Off
AC Normal Mode| Status| Red LED| Blue LED| Sound
---|---|---|---|---
Battery Full| Off| On| Off
Battery 70-90%| Off| 1 blink every 8 seconds| Off
Battery 50-70%| Off| 1 blink every 4 seconds| Off
Battery 30-50%| Off| 1 blink every 2 seconds| Off
Battery 0-30%| Off| 1 blink every second| Off
Overload 120%| Off| On| Timbrado continua
Note: the UPS will keep the sound until the main button is pressed for 1 second
Off Mode| Status
AC disconnected UPS Off completely
| Led ro·o Led azul
Timbrado
---|---|---
Off| Off| Off
CA 1/P normal Cargando baterfa| Off| 1 blink every 2 seconds| Off
UPS esta temporalizado (mediente Rs 232)| | 1 blink every 2 seconds| Off
Troubleshooting
Problem | Possible Cause | Next steps |
---|---|---|
The UPS doesn’t turn on | The battery voltage is | |
less than 10Vdc | Recharge the battery | |
Board damaged | Call service center | |
UPS always backup mode | The power cord is loose |
Insert correctly
Open Breaker| Reestablish breaker
Electrical fluid too high / too low or has
failed| The condition is normal
Plate damaged| Call service center
The backup time is too short| The battery is
not charged| Recharge the battery for 6 hours
Board damaged| Call service center
Sound alarm constantly| Overload in normal operation|
Unplugged some loads and turn on again
Overload backup mode| Unplugged some loads
Battery wear| Charge the battery
Technical Specifications
| R-UPR508i| R-UPR758i| R-UPR1008i
---|---|---|---
Capacity| 500/250W| 750/375W| 1000/500W
Input| Voltage| 220/230/240Vac
Voltage range| -30%+25%
154 -280Vac System
Max. Current| 4A/880W| 5A/1100W| 6A/1320W
Frequency| 50Hz or 60 Hz (Automatic Adjustment)
Salida| Regulation Mode| 220/230/240Vac
Frequency| 50Hz or 60Hz +/- 1Hz
Waveform| Simulated Sine Wave
Transfer Time| 2-4ms (Typical)
Outlets Nema 5- 1SR| 4 Regulated +4 Surge
Suppression
| Breaker| 4AMax.| SA Max.| 6A Max.
Bateria| Voltage| t2VDC
Type| 12V/4.5AH 1pcs| 12V/7AH 1pcs| 12V /9AH 1pcs
Recharge Time| 4hr at 90 % after completing the
recharge
Protection| Against overload and over-discharge
Alarma| Backup Mode Indicator| 2 short tones
every 8 seconds
Low Battery| 4 tones every second
Overload| Continuous sound
Failure| Continuous sound
Fun ciones| Automatic Reset| Yes
Mute Alarm| Yes
Indicator Load Mode| Yes
Short Circuit Protection| Yes
Surge Suppressor| 300Joules
Ambiente| Temperature| 0°C-40°C
Humidity| O -95 % (non condensation)
| Dimensions| 300•95•140
Warranty Policy
CDP Warranty Policy A
- Chicago Digital Power warranties this product against defective materials or workmanship for one year from the date of original purchase (With the possibility to be extended to 2 years). Proof of purchase is required.
- To make this warranty valid Proof of purchase is required.
- Bring the product to the original purchase place or the nearest CDP Service Center.
- Make sure to bring also this Warranty Policy.
- For information about Service Centers in your country please call the following numbers.
- (If your country is not here please send a mail to servicio@cdpups.com.
- Bolivia: 800-100156
- Colombia: 01800-5181617
- Costa Rica: 800-435737
- El Salvador: 800-6773
- Honduras: 001800 514 8611
- México: 001800 514 8611
- Panamá: 01 1-00800-2268611
- Perú: 0800-54674
- República Dominicana: 188-7514876
- Venezuela: 0800-1627485
- Chicago Digital Power will repair or replace the product at its criteria without a cost during the warranty period.
- Repair or replacement time should never exceed 30 days from the date that the unit is received at the CDP Service Center.
- In case this warranty policy is lost please have a copy at the original purchase place.
Warranty Limitations
- a) This warranty does not include damages that arise from negligence, misuse, or use not per the product instruction.
- b) When the product has been opened or serviced by a nonauthorized service facility, has been altered or changed.
- c) Warranty is voided if utility wiring is reversed or lacks of ground.
- d) Warranty not valid for normal wear and tear.
(Please complete and submit this information, otherwise you will not have access to the guarantee) (No guarantee will be offered if this format does not accompany the unit at the time of its return to the place of purchase)
- Calculated with basic PC and 15″LCD monitor. Estimated time.
- Specifications subject to change without notice
- Designed to be used with computers. No recommended to use with linear loads
- www.cdpups.com.