CDP UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters User Guide

June 12, 2024
CDP

**CDP UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters User Guide

**

High performance double conversion for critical loads and corporate applications

Features

  • Voltage range 60 – 150VAC. Double conversion technology.
  • Frequency regulation at output.
  • Pure sine wave output. Offers greater availability for your equipment, by correcting low and high voltages without using batteries.
  • Zero transfer time.
  • Eliminates 99% of electrical problems.
  • Cold start.
  • Allows fast recovery after overload events.
  • Ideal for protection of medical equipment, laboratory, mission critical servers or telecommunications critical servers or telecommunications.
  • Total isolation of the load from the commercial grid.
  • Maximizes battery performance, life and reliability through intelligent, precision charging intelligent, precision charging.
  • Protects the connected load against short or prolonged surges, lightning, other power irregularities and other power irregularities.
  • Converts input power to direct current (DC) and then to alternating current (AC).
  • Frequency conversion capability.
  • Power factor 0.9 at output.

User friendly LCD Display

Shows input and output voltages, backup time and battery charge.

4 NEMA 5-15R or 5-20R output terminals

Features

AC power cord NEMA 5-30P

Communication ports

Features
Hard wire output

Features

Option card: SNMP

Option card: EMD (Environmental Monitoring Device)

Task-critical solutions for corporate applications

Model   UPO11-3
Capacity   3000VA
Input   120VAC nominal voltage
Voltage range   60VAC – 150VAC
Frequency range   40Hz- 70Hz
Power factor   >/=0.99 @nominal voltage (full load)
Output  
Output voltage   110/115/120/ 127 VAC
ACvoltage regulation   +1%
Frequency range Battery mode 50 Hz +/-0.1 Hz 60 Hz +/-0.1 Hz
Crest factor   31
Overload   100% – 110: Alarm; 110/130: Battery mode: UPS shuts down in 30

seconds / Normal mode= UPS transfers to bypass mode when power is normal;

130%: Battery mode= UPS shuts down immediately / Normal mode= UPS transfers to bypass mode when power is normal
Harmonic distortion|  | </=3% THD (linear loads) </= 6% THD (non-linear loads)
Transfer time| AC mode to battery mode| zero
Waveform|  | Pure sine wave
Eficiencia|  |
Modo AC|  | 90%
Modo Eco|  | 96%
Batteries|  |
Type/Quantity|  | 12v/9Ahx 6
Recharge time|  | 4 hours to recover 90% of its capacity (typical)
Charge current|  | 1,0 Ah (max)
Charge voltage|  | 82,1VDC +/-1%
Backup time|  | Full charge 4 minutes / Half charge 9 minutes
Environment|  |
Dimensions| (length x height x depth)| 190335 x 421mm
Net weight|  | 27.6Kg
Physical|  |
Humidity|  | 20-90% RH @ 0-45°C (non-condensing)
Noise level|  | Less than 50dBA @ 1 meter
Control|  |
Smart RS232 or USB|  | Supports Windows 2000/ 2003 / XP / Vista / 2008 / 7, 8,10, Linux and Mac
Optional SNMP|  | Control and command for SNMP and web browser (via internal SNMP or SNMPDBS)
Certifications|  | NOM, 1509001, 1SO14001, CIDET