Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann Dental-
Maschinen incorporates the highest standards of quality and the latest
technology.
In order to enjoy maximum performance and years of trouble-free operation,
please read this user manual carefully before you connect this unit and start
work, and operate the unit according to the recommended guidelines. The
operation safety and the functionality of this unit can only be guaranteed if
you follow both the general safety guidelines and the applying laws to prevent
accidents as well as the precautions given in this user manual. We are not
liable for any damages which occur due to inappropriate usage or faulty
operation of this unit. Make sure that anyone using this unit has read and
understood this user manual. Keep this user manual in a safe place where it
can be referred to as required at any time.
- The unit complies with the relevant EU guidelines.
- The unit is subject to the EU guidelines 2012/19/EU (WEEE Directive).
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24 Fax.: +49 (0)40 730 37 24 export
@wassermann-dental.com
www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen
Features
-
Powerful and reliable steam cleaner, suitable for all cleaning jobs in the lab
-
Offered in two color variations: 174994 #CCVA# Wasi-Steam Compact Stainless Steel
174994 #CCWH# Wasi-Steam Compact Stainless Steel White -
Basic version: Tabletop unit, permanent water supply
NOTE: For labs without a decalcification plant we strongly recommend our water softener Wasi-Clean. The purpose of water softeners is to prevent the formation of limescale deposits caused by water hardness, which results in reduced maintenance costs. -
Optional: Strongly recommended accessory for usage with permanent water supply
-
Optional: Accessory for manual filling Flexible choice of location
NOTE: Operation with distilled/ softened water is possible and recommended. -
Operation with distilled/ softened water is possible and recommended.
-
Steam pressure 5 bar at rest/ 6 bar in operation
-
Protects seals by reducing pressure to 5 bar after a 10-minute break
-
Indication and check of operating states by LEDs
-
Service interval display
-
Simple operation, high safety standards
-
Durable, versatile and ecofriendly
-
Stainless steel housing and boiler
-
Selector for wet or dry steam
-
Optional : Accessory to regulate wet steam saturation and steam quantity
NOTE : Retrofitting is possible, the unit can be upgraded at any time. It would require to retrofit the unit at our factory or at one of our authorized service stations. Just give us a call.
Safety Symbols used in this Manual
Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening. These warnings has
to be observed.
Information!
This symbol draws your attention to specific features that has to be observed.
Information!
This symbol draws your attention to specific features that has to be
observed.
Safety Guidelines
Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual. The equipment is designed only for its intended application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connected to the correct power source.
WARNING:
- The jet nozzle is a possible source of injury, as it gets extremely hot (RISK OF SCALDING)!
- Before you use the unit for cleaning, sterilizing or degreasing, put on heat-resistant gloves and wear some form of eye protection.
- Never touch the steam gun directly at the nozzle – risk of scalding!
- Never point the steam gun at people (living beings) – risk of injury!
- The steam from the nozzle can reach temperatures up to 164°C, so only spray towards the collector or washbasin.
- For usage with a permanent water supply:
- If the unit is not to be used for an extended period, the tap should be turned off and the steam cleaner switched off.
- The tap must have a non-return valve and a breather (washing-machine tap).
- If there is a water leak, the moisture detector will switch the unit off all device functions automatically. But the unit electrically remains on. As a warning all 4 LED flashes. .
- When it is not in use, the unit switches to a temperature of 158°C and a pressure of 5 bar. The temperature increases automatically to 164°C and the pressure to 6 bar as soon as the steam gun is pressed.
- The pressure safety switch turns the unit off automatically when it reaches 7 bar.
- The TÜV-tested safety valve on the pressure vessel opens automatically if the operating pressure exceeds 9 bar.
Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or user if said device is incorrectly serviced, maintained or altered by persons not employed by an authorized dealer or if the device is used in a manner contrary to its specified purpose. The unit has to be maintained and operated in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions. Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental-Maschinen GmbH are not extended by these instructions.
Warranty
The warranty period for our equipment is 12 months. If faults occur within
the warranty period, contact your dental depot or get in touch directly with
our service department.
Your equipment should only be operated in perfect condition. If faults occur
which could harm operators or third parties, the unit should not be used until
it has been fixed.
This warranty does not cover damage caused by improper use, external
mechanical causes, transport damage or interference with the unit by
unauthorized persons.
Application
This steamer is used for cleaning, sterilizing and degreasing dental appliances. Only use the device for this type of application.
Before Starting
Transport
Before transporting the unit, ensure that it has been unplugged from the power
socket. Make sure that it is packed correctly in order to avoid accidental
damage. Be sure to check for any transport damage when unpacking the goods.
Note down any damage if found.
Installation
Open the box, remove the packing materials, and carefully lift out the device
and accessories. Check the included accessories.
The device must stand horizontally on a steady and even surface. Install the
device in a place where it will not block the working area and the
functionality (take the dimensions into account). Make sure that there are
about 10 cm of free space on each side to guarantee air circulation (heat
dissipation). Do not install the unit outdoors or in places without proper
ventilation. Before start-up, be sure the device reaches room temperature.
Storage
The unit location is very important when it comes to workplace safety, even if
it is only to be set up there for a short period. The room should be dry, well
ventilated and vibration-free. An even temperature and wooden supports also
help. The unit should not be stored or set up outdoors. If the unit is to be
stored for an extended period, protect it from moisture and dust.
Start-up/ Installation
Before starting the unit, connect up the following:
Drainage
The supplied drainage hose is connected to the drain outlet (rear side of the
unit) and fastened with the supplied hose clip.
If possible, run the hose into a heat-resistant bucket or washbasin as the
draining water can be very hot.
Permanent Water Supply
Connect the steam cleaner (rear side of the unit) to a water tap using the
supplied inlet hose (screw thread).
NOTE:
The tap must have a non-return valve and a breather (washing machine tap).
Finally, insert the power plug into the socket, making sure that the mains and
the unit operate on the same voltage.
Manual Filling
with an optional accessory (REF 174430) Fill unit, 5 Liter
NOTE:
- The filling unit must be set up on the same level as the steam jet or higher than the steam jet.
- To connect the filling unit a circuit board detection is necessary.
- The steam cleaner has to be switched off. Connect the filling unit and then switch on the steam cleaner. Now the filling unit is connected to the steam cleaner.
- Please also note the separate manual included with 174430.
Functions of the Switches and Buttons
- 6 6,3 A medium-blowing-fuse
- 7 Power switch/ Mains switch
- 8 Rinse button
- 9 Selector for dry steam
- 10 Selector for wet steam
Filling Process
Turn on the water tap (only for usage with a permanent water supply). Press the green ON/OFF switch (7). The unit will fill with water automatically by a pump and heat up. Following the procedure speeds up the filling and protects the pump (only when a permanent water supply and a required water pressure is present): For the initial filling or a refilling after draining the unit it is an option to press the black rinse button (8) on the right side of the device until the pump switches off and the filling is completed. The following procedure applies to new equipment or after the pressure vessel has been emptied. Then a one-time venting of the pressure vessel can optimize the heating-up time: After approx. 10 minutes, point the steam gun towards splash protection with tray or washbasin and press the push button until no more steam/ air/ water comes out of the nozzle. As a result, the unit is now initially pressureless. The operating pressure of 6 bar is reached after about 25 minutes, and the unit is then ready for use.
Operation
General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are
based on our own experience and experimentation and can only be regarded as
guidelines. Use the selector (9) for dry steam or (10) for wet steam.
Hold the steam gun in your hand, then release and control the steam using the
button of the gun. If the unit is not used for more than 10 minutes, it
switches to stand-by mode (5 bar). When the steam gun is operated, the unit
returns to operating temperature/ pressure (164°C, 6 bar) within 90 seconds.
Functions of the LEDs (Diodes)
- LED yellow = heating
- LED orange = operating hours counter
- LED green = water supply
- LED yellow = dry steam
- LED yellow = wet steam
-
LED (1) off = Heating off (Heating protection: The water level is below the sensor „ water level min.“)
-
LED (1) illuminated = Heating on (The water level is at the same height as or above the sensor „ water level min.“)
-
LED (2) flashes = operating hours counter = 100 h/ Rinsing the tank is recommended Although it is still possible to work with the steam cleaner. and to reset the operating hours counter to 0.
RESET: The unit must be switched off. Then press the dry steam button (9) and switch on the device with the main switch (7) at the same time. -
LED (3) flashes = Low water, water supply, pump runs (The water level is below the sensor „ water level min.“)
-
LED (3) illuminated = Water supply, pump runs (The water level is at the same height as or above the sensor „ water level min.“)
-
LED (3) off = Water level ok, pump off
-
LED (4) or (5) flashes fast = Heating (1) on, units pressure < 5 bar
-
LED (4) or (5) flashes slow = Heating (1) on, units pressure = 5 bar or > 5 bar
-
LED (4) or (5) illuminated = Heating (1) off, units pressure = 6 bar
or -
Heating (1) off, units pressure = 5 bar after 10-minute break (stand by mode)
-
LED`s (1), (3), (4) and (5) flashes = If there is a water leak, the moisture detector will switch the unit off all device functions automatically. But the unit electrically remains on. As a warning all 4 LED flashes.
Troubleshooting
Fault | Cause | Solution |
---|
No LEDs displayed and/or
only ON/OFF switch illuminated
| Blown fuse| Replace fuse.
Trace cause or contact Service Department
Temperature/ pressure too high| A pressure safety switch turns the unit off automatically when it reaches 7 bar.
Trace cause or contact Service Department.
Hot water rather than steam comes from nozzle| Container overfilled with water.
This can happen if the rinse button
(8) was pressed too long when filling (mains water).
| Set unit to dry steam and spray until only steam comes out.
Collection tray spills over| Collection tray is full| Empty the collection
tray or connect the drainage hose (wash basin)
Water supply LED (3) on continuously| No water flow| Check tap and connections
LED (2) flashes
(operating hours counter
= 100)
| Rinsing the tank is recommended| Rinse container according to instructions.
RESET: The unit must be switched off. Then press the dry steam button (9) and
switch on the device with the main switch (7) at the same time.
Heating LED (1) on continuously with no increase in pressure| Faulty heating|
Contact Service Department
LED (1), (3), (4), (5) flash| Unit leaking| Contact Service Department
If the above recommendations do not solve the problem, contact your dental depot or our service department.
Care and Maintenance
Cleaning
- Disconnect the power plug before starting any maintenance work.
- The identification plate has always to be kept in easily legible condition and has not to be removed. Remove external dirt from time to time with some form of cold cleaner.
- Use only cold cleaners to avoid damaging the paintwork or removing the lettering. The equipment should be cleaned at regular intervals to ensure trouble-free operation.
- It requires only normal cleaning (sponge, damp cloth, mild detergent) and no further chemical additives.
Maintenance
The unit should be descaled depending on use, but at least every 14 days,
according to the following instructions. Basically, it should be ensured that
the unit is kept clean. Calcification can be minimized depending on use, which
extends the cleaning intervals.
- Permanent water supply: The purpose of water softeners is to prevent the formation of limescale deposits caused by water hardness, which results in reduced maintenance costs. We strongly recommend to use our Wasi-Clean water-softener.
- Manual filling: Operation with our fill unit (5 Liter) allows to use of distilled/ softened water.
Rinsing/ Decalcification
Rinse the steam boiler only after the pressure has dropped to zero.
Otherwise, there is a very high risk of scalding.
The unit is equippped with an operating hours counter:
-
When 100 hours are counted the LED (2) flashes. Rinsing the tank is recommended. It is still possible to work with the steam cleaner.
-
RESET the operating hours counter to 0: The unit must be switched off. Then press the dry steam button (9) and switch on the device with the main switch (7) at the same time.
When draining the water, please note the following: -
Turn the main switch off
-
Before draining the water, make sure that the unit has cooled down.
-
Activate the steam gun. The unit must be cooled and relieved of pressure.
-
Before draining the water, make sure that the hose runs into a heat-resistant bucket or washbasin. For safety reasons, you should firmly install the drain hose as the draining water can be very hot (up to 164 ° C if the device has not cooled down).
-
Using the black rotary knob at the rear side of the unit, carefully open the drain valve slowly to the end.
Then switch the unit to rinsing mode as follows:
-
With the button of the steam gun pressed, switch on the unit and keep the steam gun button pressed for a short time.
-
Both steam LEDs light up = protective function.
-
Now release the steam gun button.
-
Rinse mode on = steam LEDs flash alternately.
-
In this mode the heating is switched off. And with the wet steam button (10) the pump in the unit (intermittent operation 20/10 sec.) can be switched on or off for rinsing.
-
In this mode both valves are opened by pressing the steam gun button (air balance in the boiler), which increases the outflow speed when draining the water.
-
Permanent Water Supply:
-
By pressing the flush button (8) on the right side of the unit, the pressure (= water pressure in the building) can be increased during flushing in order to flush the sludge chamber in the steam boiler even more effectively until only clear water comes out.
-
Manual Filling:
When using the filling unit, only the pump in the unit is used for rinsing. In order to achieve the best possible result, we recommend connecting the device to a mains water supply for rinsing. -
Now turn the drain valve with the black button (rear side of the unit) clockwise again to close the water outlet.
-
Now exit the rinsing mode by switching off the unit.
-
If you now switch on the unit only with the main switch (7) (= normal mode), you can put the device back into operation according to section 7.2 Initial filling.
-
Place the splash protection (if applicable) in front of the steam cleaner.
Repairs
Servicing or repairs to the unit has only to be carried out by qualified technicians. Only original spare parts are to be used. Responsibility for the product is voided if unauthorised persons alter it or if inappropriate components are installed.
Spare Parts
If necessary please contact our service hotline phone.
Service Hotline 0049 (0)40 730 926 -20/ -2
Scope of Delivery/ Accessories
Included in delivery:
- Supply hose, grey, cpl.
- Discharge hose, 1,5 m
- Hose clip Ø 12-20 x 9
Accessories | Item no. |
---|---|
Wasi-Clean water softener, table top unit (W 190 x H 405 x D 260 mm) | 174997 |
Splash protection entirely made of stainless steel
(W 250 x H 265 x D 255 mm)
| 174460
Fill unit ( 5 Liter)
(W 215 x H 340 x D 240 mm) (D + connection = 290 mm)
| 174430
Special spray nozzle Ø 2.5 mm
(Spare basic nozzle Ø 1.2 mm, item no. 174100)
| 174352
Quantity Control Accessory Set*
Accessory to regulate wet steam saturation and steam quantity
*Retrofitting is possible, the unit can be upgraded at any time. It would require to retrofit the unit at our factory or at one of our authorized service stations. Just give us a call.
| 174414
Discharge hose per meter| 320031
Technical Data
Wasi-Steam Compact | Item no.: 174994 |
---|---|
Voltage | 220–240 V / 50/60 Hz |
Power consumption | 5.5 A (6.3 A medium-blowing-fuse) |
Output | 1270 W |
W x H x D max.
W x H x D (housing)
| 345 x 360 x 390 mm
300 x 353 x 310 mm
Weight| 19 kg
Working pressure| max. 6 bar (stand by 5 bar)
Steam temperature| max. 164°C at 6 bar
Boiler capacity| 3.3 l
Safety class| IP 22
Duty| Interrupt operation 5/5 min
Other voltages on request.
The noise level of the unit amounts to ≤ 70 dB (A). Technical changes
reserved.
Disposing of the Unit
The unit has to be disposed by an authorized recycling operation. The selected company has to be informed of all possibly health-hazardous residues in the unit.
Information on Disposal for Countries within the EU
To conserve and protect the environment, prevent environmental pollution,
and improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling. Within the European
Union units with this symbol should not, therefore, be disposed of in the
unsorted domestic waste. For more information regarding proper disposal please
apply at your local authorities.
EU Declaration of Conformity
in accordance with 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive) and 2006/42/EC (Machinery Directive) and 2011/65/EU (RoHS Directive) and 2014/68/EU (Pressure Units Directive)
- Manufacturer : W A S S E R M A N N
- Dental-Maschinen GmbH Rudorffweg 15-17 21031 Hamburg Germany
- Model: Wasi-Steam Compact
- Applicable standards:
- DIN EN 61010-1
- DIN EN 61000-6-3
- DIN EN 61000-6-1
- DIN 45635-1
- DIN EN 60335-1
- Product description: Steam Cleaner for
- dental applications
- Item no. 174994
Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EU- Richtlinien entspricht. Diese Erklärung wird ungültig, falls die Maschine ohne unsere Zustimmung verändert wird. This is to confirm that the above-mentioned machine complies with the described EU guidelines. This declaration becomes invalid if the machine is modified without our approval. Cette machine est conforme aux normes en vigueur d´Union européenne. Cet avis est nul et non avenant si cette machine est modifiée sans notre accord. Esta máquina, anteriormente mencionada, cumple con los limites requeridos por el reglamento UE. Ahora bien, esta declaración quedará invalidada en caso de realizar modificaciones al aparato sin nuestra aprobación. Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen. Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht.
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17 · 21031 Hamburg· Deutschland
Tel.: +49 (0)40 730 926-0 · Fax: +49 (0)40 730 37 24
info@wassermann-dental.com ·
www.wassermann.hamburg
References