WASSERMANN WGS-25 W II Plaster Storage Bin Wall-Mounted Model
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann Dental-
Maschinen incorporates the highest standards of quality and the latest
technology.
In order to enjoy maximum performance and years of trouble-free operation,
please read this user manual carefully before you connect this device and
start work, and operate the device according to the recommended guidelines.
The operation safety and the functionality of this device can only be
guaranteed if you follow both the general safety guidelines and the applying
laws to prevent accidents as well as the precautions given in this user
manual. We are not liable for any damages which occur due to inappropriate
usage or faulty operation of this device.
-
Make sure that anyone using this device has read and understood this user manual.
Keep this user manual in a safe place where it can be referred to as required at any time. -
The unit complies with the relevant EU guidelines.
-
The unit is subject to the EU guidelines 2012/19/EU (WEEE Directive).
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
- Phone : +49 (0)40 730 926 -20/ -24
- Fax.: +49 (0)40 730 37 24
- export@wassermann-dental.com
- www.wassermann.hamburg
- www.facebook.com/WassermannDentalmaschinen
Features
- The established bin for all plasters, embedding materials, and pumice powder
- Fine control of material flow thanks to variable vibration intensity
- Can be tilted at 180° for easy refilling
- Very sturdy steel construction
- Scratch-resistant plastic powder coating for easy cleaning
- Optimized for use with Wassermann DSW-2 and DSW-2/4 K dosing scales
Safety Symbols Used in this Manual
Warning!
This is a warning of risk situations and dangers. Failure to observe this
warning could be life-threatening. These warnings have to be observed.
Information!
This symbol draws your attention to specific features that have to be
observed.
Safety Guidelines
Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual. The equipment is designed only for its intended application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connected to the correct power source.
Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or
user if said device is incorrectly serviced, maintained or altered by persons
not employed by an authorised dealer or if the device is used in a manner
contrary to its specified purpose. The unit has to be maintained and operated
in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not
responsible for damage arising from the nonobservance of these instructions.
Warranty and responsibility provisions contained in the sales and supply
conditions of Wassermann Dental-Maschinen GmbH are not extended by these
instructions.
Application
The plaster storage bin is designed to store all kind of plasters, embedding
materials and pounces in a dry environment protected from dirt. By simply
pressing a knob, the material flows out constantly under close control, free
from any lumps.
Only use the device for this type of application.
Before Starting
Transport
Before transporting the unit, ensure that it has been unplugged from the power
socket. Make sure that it is packed correctly in order to avoid accidental
damage.
Be sure to check for any transport damage when unpacking the goods. Note down any damage if found.
Installation of the Wall-mounted Model
Open the box, remove the packing materials, and carefully lift out the device
and accessories. Check the included accessories.
Screw the unit with the supplied mounting kit onto a stable, bearing wall in
the desired height level.
- Install the device in a place where it will not block the working area and the functionality (take the dimensions into account).
- Do not install the unit outdoors or in places without proper ventilation. Before start-up, be sure the device reaches room temperature.
Storage
The unit location is very important when it comes to workplace safety, even if it is only to be set up there for a short period. The room should be dry, well ventilated and vibration-free. An even temperature and wooden supports also help. The unit should not be stored or set up outdoors. If the unit is to be stored for an extended period, protect it from moisture and dust.
Installation/ Start-up
Initial Filling/ Refilling
- Loosen the lock bolt and pull out the silo by holding it by the handle until the lock bolt locks again.
- Loosen the lever and rotate the silo 180° until the lever locks again.
- Crank the handle downwards until the storage bin becomes free.
- Fill the empty storage bin and place it inside the silo again.
- Crank the handle upwards until the storage bin is placed firmly.
- Loosen the lock bolt, turn the silo 180° until the lever locks again.
- Loosen the lock bolt and push the silo back by holding it by the handle until the guide bolts, connections, and lock bolts lock again properly.
Finally, insert the power plug into the socket, making sure that the mains and the unit operate on the same voltage.
Operation
General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are based on our own experience and experimentation and can only be regarded as guidelines.
- The unit is now ready for operation.
- Remove the rubber stopper at the lower outlet.
- Place the storage bin for plaster, embedding material, etc. under the outlet.
- Now it is possible to retrieve material by pressing the lower knob.
- The upper knob with the round arrow is provided to adjust the vibrating intensity.
- To stop operation disconnect the power plug.
Disconnect the power plug when not using the unit for a long period of time.
Troubleshooting
Fault | Cause | Solution |
---|---|---|
No vibrations. | The power plug is not connected. | Check the power plug and |
connect it.
The plug connection is not locked.| Check the plug connection and relock.
No plaster comes out.| The rubber stopper is not removed.| Check the rubber
stopper and remove it.
The storage bin is empty.| Check the storage bin and refill it.
If the above recommendations do not solve the problem, contact your dental depot or our service department.
Care and Maintenance
Cleaning
-
Disconnect the power plug before starting any maintenance work.
The identification plate has always to be kept in easily legible condition and has not to be removed. -
Remove external dirt from time to time with some form of cold cleaner.
Use only cold cleaners to avoid damaging the paintwork or removing the lettering. The equipment should be cleaned at regular intervals to ensure trouble-free operation.
It requires only normal cleaning (sponge, damp cloth, mild detergent) and no further chemical additives.
Maintenance
The unit does not require any servicing. Just make sure that the device is kept clean.
Repairs
Servicing or repairs to the unit have only to be carried out by qualified technicians. Only original spare parts are to be used. Responsibility for the product is voided if unauthorized persons alter it or if inappropriate components are installed.
Spare Parts
If necessary please contact our service hotline phone.
Service Hotline 0049 (0)40 730 926 -20/ -24
Scope of Delivery/ Accessories
Scope of Delivery: | Item No. |
---|
WGS-25 W I I Wall Model complete incl. fastening material:
5 ST Screw DIN 571 8 X 80
5 ST Washer DIN 125 A 8.4
5 ST Dowel FISCHER S 10
| 166997
Accessories:| Item No.
---|---
Table-Top Support incl. fastening material (available on request)| 166115
Warranty
The warranty period for our equipment is 12 months. If faults occur within the
warranty period, contact your dental depot or get in touch directly with our
service department.
Your equipment should only be operated in perfect condition. If faults occur
which could harm operators or third parties, the unit should not be used until
it has been fixed.
This warranty does not cover damage caused by improper use, external
mechanical causes, transport damage or interference with the unit by
unauthorized persons.
Technical Data
- WGS-25 W II Item no.: 166997
- Voltage: 220–240 V / 50/60 Hz
- Power consumption: 0.3 A
- Output: 70 W
- Dimensions wall-mounted version: W 445 x H 910 x D 415 mm / D max. 810 mm
- *Dimensions incl. table-top support:** W 445 x H 1065 x D 415 mm / D max. 810 mm
- Weight WGS-25 W II: 45 kg
- Weight Accessory Table-Top Support: 6,7 kg
- Sound level: ≤ 70 dB (A)
Other voltages on request.
The noise level of the unit amounts to ≤ 70 dB (A).
Technical changes reserved.
- Table-Top Support (REF. 166115, available on request)
Disposing of the Unit
The unit has to be disposed by an authorized recycling operation. The selected company has to be informed of all possibly health-hazardous residues in the unit.
Information on Disposal for Countries within the EU
To conserve and protect the environment, prevent environmental pollution, and
improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling.
Within the European Union units with this symbol should not, therefore, be
disposed of in the unsorted domestic waste.
For more information regarding proper disposal please apply at your local
authority.
EU Declaration of Conformity
in accordance with 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive) and 2006/42/EC (Machinery Directive) and 2011/65/EU (RoHS Directive)
-
Manufacturer:
WASSERMANN
Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg
Germany -
Model:
WGS-25 W II -
Applicable
DIN EN 61010-1 -
standards:
DIN EN 61000-6-3
DIN EN 61000-6-1
DIN 45635-1
DIN EN 60335-1 -
Product description:
Plaster Storage
Bin for dental
applications -
Item no.
166997
This is to confirm that the above-mentioned machine complies with the described EU rules. This declaration becomes invalid if the machine is modified without our approval.
Place, date: Hamburg, 2022-03-09
Signature: ____
Company stamp :
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17 · 21031 Hamburg· Germany
- Phone: +49 (0)40 730 926-20/ -24 ·
- Fax: +49 (0)40 730 37 24
- export@wassermann-dental.com
- www.wassermann.hamburg
- Facebook: /Wassermann Dentalmaschinen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>