WASSERMANN WW-33 Hydraulic Press for 1-3 Flasks Owner’s Manual
- June 5, 2024
- WASSERMANN
Table of Contents
WW-33 Hydraulic Press for 1-3 Flasks
Hydraulic Press WW-33
2-4 flasks 1-3 flasks (Fig.)
SERVICE MANUAL
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann Dental Maschinen incorporates the highest standards of quality and the latest technology. In order to enjoy maximum performance and years of trouble-free operation, please read this service manual carefully before you connect this device and start work, and operate the device according to the recommended guidelines. The operation safety and the functionality of this device can only be guaranteed if you follow both the general safety guidelines and the applying laws to prevent accidents as well as the precautions given in this service manual. We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device.
Make sure that anyone using this device has read and understood this service
manual. Keep this service manual in a safe place where it can be referred to
as required at any time.
The unit complies with the relevant EU guidelines.
Company address:
Wassermann Dental-Maschinen GmbH Rudorffweg 15-17 21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24 Fax.: +49 (0)40 730 37 24 export
@wassermann-dental.com www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen
1 Features
The WW-33 hydraulic press, with continuous pressure up to 6 tonnes, presses caps individually and appropriately for the material used. After ending one pressing, it is immediately ready for further use as its solid plastic piston returns automatically once the valve has been opened. A quality pressure gauge which shows the pressure achieved with great accuracy, is recessed into the housing and is thus protected from dirt. The WW-33’s oxidation-free piston (plastic), tensile steel construction (no risk of breaking), and sturdy plastic-coated housing all contribute to the unit’s long service life. As the distance between supports is 152 mm, the press is also suitable for larger caps (IVOCAP) and stirrup pieces.
SPECIAL DESIGN:
The WW-33 hydraulic press is also available with longer supports for 4 caps.
- Break-proof hydraulic press in drawn steel for pressing 13 or 24 flasks
- Pressure infinitely adjustable up to 6 tonnes
- Rust-proof piston made of super-strong material
- Automatic piston return after opening of valve
- Plastic powder coated housing
- Quality pressure gauge with precision display recessed in housing
- Distance of columns of 152 mm to allow use of larger flasks and flask clamps
- High stability
- Integrated oil level display
2 Safety Symbols used in this Manual
Warning!
This is a warning of risk situations and dangers. Failure to observe this
warning could be life-threatening. These warnings has to be observed.
Information!
This symbol draws your attention to specific features that has to be observed.
3 Safety Guidelines
Configuring and operating this equipment requires precise knowledge and
observance of the instructions in this service manual. The equipment is
designed only for its intended application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
4 Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or user if said device is incorrectly serviced, maintained or altered by persons not employed by an authorized dealer or if the device is used in a manner contrary to its specified purpose. The unit has to be maintained and operated in accordance with this service manual. Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions. Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental-Maschinen GmbH are not extended by these instructions.
5 Application
With a continuous working pressure of up to 6 tonnes, the WW-33 hydraulic press is used to press caps individually and in accordance with the material used. Only use the device for this type of application.
6 Before Starting
6.1 Transport Before transporting the unit, ensure that it has been
unplugged from the power socket. Make sure that it is packed correctly in
order to avoid accidental damage.
Be sure to check for any transport damage when unpacking the goods. Note down
any damage if found.
6.2 Installation
Open the box, remove the packing materials, and carefully lift out the device
and accessories. Check the included accessories. The device has to stand
horizontally on a steady and even surface.
Install the device in a place where it will not block the working area and the
functionality (take the dimensions into account).
Do not install the unit outdoors or in places without proper ventilation.
Before start-up, be sure the device reaches room temperature.
6.3 Storage
If the unit is to be stored for an extended period, protect it from moisture
and dust.
7 Installation/ Start-up
Please remove the safety packing as follows:
-
Take the pump lever out of the union piece.
-
Undo the bolt and remove the red safety packing. Insert the lever and secure it
with the bolt. -
Screw the ball on the end of the lever.
-
Centre the cap on the piston to guarantee even pressure distribution.
-
Bring down the piston on the cap.
The usual pressure is between 2.5 and 5 tones. This is shown in the green area on the pressure gauge. To avoid damage to the cap and the press, do not pump beyond the zone on the pressure gauge.
8 Operation
8.1 General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are based on our own experience and experimentation and can only be regarded as guidelines.
-
Prepare cap as per Point 7.
-
Turn the pressure valve (black knob on housing) to CLOSED.
-
Now increase pressure with the lever, staying within the permissible zone on the
pressure gauge (green zone). -
If necessary, increase the pressure to the maximum, always staying within the
permissible zone on the pressure gauge (green zone). -
Once the pressure remains steady, it can be released (valve opened).
-
Raise the piston and remove the cap.
The gauge will not be accurate while the pressure is being distributed through the plastic. Full pressure can only be achieved by pumping on the lever several times with appropriate pauses in between. Once the cap is fully enclosed, the pressure remains steady.
The return spring on the piston takes it back automatically to its zero position. It has a stroke of about 12 mm. As soon as it reaches this level, it is limited automatically. No more pressure is possible.
The oil level should be monitored on the gauge when the piston is down. If
necessary, add hydraulic oil. A black vent screw is provided for this purpose.
To remove (oil filler nozzle). This is located behind the left-hand support at
the top of the housing. No damage can result from overfilling as the surplus
oil merely flows out into the nozzle.
Note: Use only SHELL TELLUS 32 hydraulic oil.
9 Troubleshooting
Fault
|
Cause
|
Solution
---|---|---
Little or no pressure builds
|
Oil level below minimum and air bubble has entered system during filling
|
Vent press as explained below Point 9.1
Pressure drops to zero despite enclosed cap or piston rises under pressure
|
Dirty pressure valve
|
Pump strongly with newly filled oil (recommended oil)
9.1 Guidelines for Venting:
1. Turn press on right side and pump.
2. Nothing? – then remove piston as described below and fill with oil up to
top edge of cylinder:
- Undo set screw in U-piece
- Pull lever forwards
- Pull piston up and out of cylinder
- Fill with oil (recommended oil)
- Re-install in reverse order, watching out for two points:
- Do not tip the piston
- Do not damage the square ring
If the above recommendations do not solve the problem, contact your dental depot or our service department.
10 Care and Maintenance
10.1 Cleaning
The identification plate has always to be kept in easily legible condition and has not to be removed.
Remove external dirt from time to time with some form of cold cleaner. Use only cold cleaners to avoid damaging the paintwork or removing the lettering. The equipment should be cleaned at regular intervals to ensure trouble-free operation.
It requires only normal cleaning (sponge, damp cloth, mild detergent) and no further chemical additives.
The piston track should be cleaned daily with a clean linen cloth and then lightly lubricated with the recommended hydraulic oil.
10.2 Maintenance
The hydraulic press does not require any servicing. Just make sure that the device is kept clean.
10.3 Repairs
Servicing or repairs to the unit has only to be carried out by qualified technicians. Only original spare parts are to be used. Responsibility for the product is voided if unauthorised persons alter it or if inappropriate components are installed.
10.4 Spare Parts
If necessary please contact our service hotline phone.
10.5 Service Hotline 0049 (0)40 730 926 -20/ -24
10.6 Scope of Delivery/ Accessories
Included parts
|
Item no.
---|---
WW-33 for 2-4 flasks
|
126998
WW-33 for 1-3 flasks
|
126999
Accessories
|
Item no.
---|---
Universal flask
|
129990
Stainless steel clamp clip for 3 flasks
|
129992
Stainless steel clamp clip for 2 flasks
|
129993
Stainless steel clamp clip for 1 flask
|
129994
Universal flask clamp for 3 flasks
|
129995
Universal flask clamp for 2 flasks
|
129996
Universal flask clamp for 1 flask
|
129997
Hydraulic oil 500 ccm
|
629005
10.7 Warranty
The warranty period for our equipment is 12 months. If faults occur within the warranty period, contact your dental depot or get in touch directly with our service department.
Your equipment should only be operated in perfect condition. If faults occur which could harm operators or third parties, the unit should not be used until it has been fixed.
This warranty does not cover damage caused by improper use, external mechanical causes, transport damage or interference with the unit by unauthorized persons.
11 Technical Data
WW-33, 2–4 flasks
WW-33, 1–3 flasks
|
Item no.: 126998
Item no.: 126999*
---|---
W x D / D with pump lever
|
200 x 158 / 295 mm
Height
|
max. 710 / min. 540 mm
max. 650 / min. 480 mm*
Distance between columns
|
152 mm
Distance plunger plate
|
max. 272 / min. 102 mm
max. 212 / min. 42 mm*
Weight
|
16,0 kg
14,7 kg*
Working pressure
|
up to 6 tons
Working table
|
Ø 95 mm
Technical changes reserved.
12 EU Declaration of Conformity
in accordance with 2006/42/EC (Machinery Directive)
Manufacturer: W A S S E R M A N N Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg
Germany
Product description: Hydraulic Press for dental
applications
Model: WW-33 for 2-4 flasks (special design) WW-33 for 1-3 flasks
Item no.126998 Item no.126999
Applicable standards:
DIN EN ISO 12100
This is to confirm that the above mentioned machine complies with the described EU guidelines. This declaration becomes invalid if the machine is modified without our approval.
Place, date: Hamburg, 2021-04-13 Company stamp :
Signature: ____
Sven Wassermann
(Managing Director)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>