WASSERMANN 174970 Steam Box Cleaning Cabin for Workpieces User Manual
- June 5, 2024
- WASSERMANN
Table of Contents
- Features
- Safety Symbols Used in this Manual
- Safety Guidelines
- Responsibility for Operation or Damage
- Application
- Before Starting
- Installation/ Start-up
- Operation
- Troubleshooting
- Care and Maintenance
- Technical Data
- Disposing of the Unit
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
174970 Steam Box Cleaning Cabin for Workpieces
User Manual
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann
DentalMaschinen incorporates the highest standards of quality and the latest
technology. In order to enjoy maximum performance and years of trouble-free
operation, please read this user manual carefully before you connect this
device and start work, and operate the device according to the recommended
guidelines. The operation safety and the functionality of this device can only
be guaranteed if you follow both the general safety guidelines and the
applying laws to prevent accidents as well as the precautions given in this
user manual. We are not liable for any damages which occur due to
inappropriate usage or faulty operation of this device.
** Make sure that anyone using this device has read and understood this
user manual.
Keep this user manual in a safe place where it can be referred to as required
at any time.
The unit complies with the relevant EU guidelines.
The unit is subject to the EU guidelines 2012/19/EU (WEEE Directive).
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
Phone** : +49 (0)40 730 926 -20/ -24
export@wassermann-dental.com
www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen
Features
- Compact cleaning cabin for steam cleaning of workpieces
- Generous working opening (W= 285 mm, H= 235 mm)
- Quick steam extraction through the powerful fan with run-on control
- Fan control selectable between continuous operation and automatic mode
- Automatic fan operation selectable via foot pedal or hand sensor control
- Extracted steam condenses using a floor filter, with the chassis floor serving as a collecting tray
- This condensate drain tray can be emptied using the ball valve on the side
- With practical grip plates: The work cabin can be quickly dismantled to clean the condensate drain tray
- Separate protective filter in front of the fan
- Pleasant workspace illumination with LED light
- Almost entirely made of stainless steel
- Low-maintenance, easy to clean, and care
Safety Symbols Used in this Manual
Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening.
These warnings have to be observed.
Information!
This symbol draws your attention to specific features that have to be
observed.
Safety Guidelines
Configuring and operating this equipment requires precise knowledge and
observance of the instructions in this user manual. The equipment is
designed only for its intended application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connected to the correct power source.
In automatic mode, the fan has a run-on control, i.e. when the fan is switched
off using the foot pedal or hand sensor control, it continues to run for a few
seconds.
Depending on the intensity of work, the water should be drained from the
collecting tray via the ball valve, because the capacity is limited.
Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or
user if said device is incorrectly serviced, maintained, or altered by persons
not employed by an authorized dealer or if the device is used in a manner
contrary to its specified purpose. The unit has to be maintained and operated
in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not
responsible for damage arising from the nonobservance of these
instructions.
Warranty and responsibility provisions contained in the sales and supply
conditions of Wassermann Dental-Maschinen GmbH are not extended by these
instructions.
Application
The Steam Box is a compact work cabin for cleaning workpieces with steam.
It is designed for the cleaning of small parts up to hand-sized parts.
A powerful fan, which quickly extracts the steam via a floor filter, and work
area illumination with LED light ensure optimum visibility when working.
Only use the device for this type of application.
Before Starting
6.1 Transport
Before transporting the unit, ensure that it has been unplugged from the power
socket. Make sure that it is packed correctly in order to avoid accidental
damage.
Be sure to check for any transport damage when unpacking the goods. Note down
any damage if found.
6.2 Installation
Open the box, remove the packing materials and carefully lift out the device
and accessories. Check the included accessories.
The unit has to stand horizontally on a steady and even surface.
Install the device in a place where it will not block the working area and the
functionality (take the dimensions into account).
Do not install the unit outdoors or in places without proper ventilation.
Before start-up, be sure the device reaches room temperature.
6.3 Storage
The unit location is very important when it comes to workplace safety, even if
it is only to be set up there for a short period. The room should be dry, well
ventilated, and vibration-free. An even temperature and wooden supports also
help. The unit should not be stored or set up outdoors. If the unit is to
be stored for an extended period, protect it from moisture and dust.
Installation/ Start-up
Before starting the unit, connect up the following:
Install the drain hose included in delivery and provide a suitable drainage
facility.
Note: For easier assembly of the hose, the hose connector should be
coated thinly with a soft soap or washing-up liquid.
7.1 Start-up
Before the first usage of the cleaning cabin, please completely remove all
accessories and the packaging material.
Before using the cleaning cabin, select the fan operating mode, i.e. whether
the fan is always switched on (continuous operation) or only when working
(automatic mode). In the automatic version, you can choose between a hand
sensor and foot pedal control. If you choose the foot pedal version, place the
foot pedal in a position that is comfortable for you.
When switching the selector button to footswitch mode, only the footswitch is
active, the hand sensors are switched off.
The foot switch cannot be switched off. Working with the foot switch is also
possible in hand sensor mode.
When walking past the unit, the automatic manual sensor control may cause the
fan to function unintentionally.
This is technically due to the set sensor detection range.
If the fan starts up too often unintentionally due to the space available,
this can be switched off by switching the fan to foot pedal operation or, in
the case of a longer break from work, by turning off the green main switch.
Finally, insert the power plug into the socket, making sure that the
mains and the unit operate on the same voltage.
Operation
8.1 General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are
based on our own experience and experimentation and can only be regarded as
guidelines.
Use heat-resistant gloves or holding tools for the parts to be cleaned.
If the unit is not used for a longer period of time, the main plug should be
pulled out.
The filter inserts should be changed at suitable intervals in order to achieve
optimal suction performance.
Since the capacity of the collecting tray is limited, depending on the
intensity of work, you should let the collected water run off via the ball
valve (drain).
8.2 Handling of the Unit
- Select the appropriate operating mode of the fan using the selector switch.
- Turn on the green main switch.
- Hold the workpiece to be cleaned in the work cabin and clean it with a steam gun.
Troubleshooting
Fault | Cause | Solution |
---|---|---|
The fan does not switch off | Continuous operation selected | Control fan |
selector button
Automatic mode – lag circuit board defective| Please contact our
service/Repair (service workshop)
Automatic mode – foot switch defective| Switch to hand sensor or Please
contact our service
Automatic mode – hand sensor defective| Switch to footswitch or Please contact
our service
The fan does not turn on| Fan defective| Please contact our service/Repair
(service workshop)
Automatic mode – foot switch defective| Switch to hand sensor or Please
contact our service
Automatic mode – hand sensor defective| Switch to footswitch or Please contact
our service
Dark workroom| LED lighting defective| Please contact our service
Steam box without function| The main switch (green) is defective or the fuse
of the socket defective| Please contact our service or
Check the fuse/replace if necessary – if defective repeatedly, then, please
contact service – if necessary, service workshop
If the above recommendations do not solve the problem, contact your dental depot or our service department.
Care and Maintenance
10.1 Cleaning
Disconnect the power plug before starting any maintenance work.
The identification plate has always to be kept in easily legible condition and
has not to be removed.
Remove external dirt from time to time with some form of cold cleaner.
Use only cold cleaners to avoid damaging the paintwork or removing the
lettering.
Depending on the intensity of work and the degree of soiling, the viewing
window in the ceiling area (above) of the work area should be cleaned for
optimal illumination of the work area.
The two sensors mounted outside on the front of the housing should be cleaned
at regular intervals to ensure trouble-free operation.
10.2 Maintenance
Check the filter inserts for leakage at regular intervals. If the dirt is too
heavy, the corresponding filter elements must be replaced in order to ensure
optimal steam extraction.
To check the filter element – the protective filter (fan), you must remove the
front of the housing with the steam cabin, as described below. Then unscrew
the knurled screws (2x) on the rear and remove the filter holder. After
checking or replacing the filter element, reassemble the filter holder.
Check the collecting tray for deposits or blockages in the drain hole at
regular intervals. For optimal drainage of the collecting tray, the opening
should be kept free and cleaned. To do this, remove the two screws in the
front of the housing and carefully pull the front of the housing forward with
the help of the two grip plates. After that disconnect the plug connection
(6-pin) and then pull the front of the housing with the steam cabin forward
using the grip plates and set it aside. Now you can check the collecting tray
(= chassis floor) and the drain hole as well as other filter elements. Then
reassemble the steam box accordingly.
10.3 Repairs
Servicing or repairs to the unit have only to be carried out by qualified
technicians. Only original spare parts are to be used. Responsibility for the
product is voided if unauthorized persons alter it or if inappropriate
components are installed.
10.4 Spare Parts
If necessary please contact our service hotline phone.
10.5 Service Hotline 0049 (0)40 730 926 -20/ -24
10.6 Scope of Delivery/ Accessories/ Spare Parts
Steam Box (Item no. 174970)
Included in delivery:
- Drain hose, 2 m
Accessories | Item no. |
---|---|
Floor filter (workspace), 1 piece | 174508 |
Protective mat (workspace), 1 piece | 174507 |
Protective filter (fan), 1 piece | 174509 |
Drain hose, per meter | 320018 |
10.7 Warranty
The warranty period for our equipment is 12 months. If faults occur within the
warranty period, contact your dental depot or get in touch directly with our
service department.
Your equipment should only be operated in perfect condition. If faults occur
which could harm operators or third parties, the unit should not be used until
it has been fixed.
This warranty does not cover damage caused by improper use, external
mechanical causes, transport damage, or interference with the unit by
unauthorized persons.
Technical Data
Steam Box | Item no.: 174970 |
---|---|
Voltage* | 220–240 V / 50/60 Hz |
Power consumption | 0.8 A |
Output | 140 W |
W x H x D (max.) | 421 x 476 x 549 mm |
W x H x D (housing) | 393 x 476 x 515 mm |
W x H (working opening) | 285 x 235 mm |
Protection class | IP 44 |
Weight | 26.5 kg |
Other voltages on request.
The noise level of the unit amounts to 70 dB (A).
Technical changes reserved.
Disposing of the Unit
The unit has to be disposed of by an authorized recycling operation. The
selected company has to be informed of all possibly health-hazardous residues
in the unit.
12.1 Information on Disposal for Countries within the EU
To conserve and protect the environment, prevent environmental pollution, and
improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling.
Within the European Union units with this symbol should not, therefore, be
disposed of in the unsorted domestic waste.
For more information regarding proper disposal please apply to your local
authorities.
Your Contact at Wassermann Dental-Maschinen
https://www.wassermann.hamburg/en/company/contacts.html
Do you have questions concerning our products or services?
Contact us! We guarantee the quickest possible handling and we will provide
you personally with competent, dedicated help. Thank you for contacting us!
Phone: +49 (0)40/ 730 926 – 24
export@wassermann-dental.com
EU Declaration of Conformity
in accordance with 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive) and 2006/42/EC (Machinery Directive) and 2011/65/EU (RoHS Directive)
Manufacturer:| WASSERMANN
Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg
Germany| Product description:| xxx for dental applications
---|---|---|---
Model:| Steam Box| Item no.| 174970
Applicable standards:| DIN EN 61010-1
DIN EN 61000-6-3
DIN EN 61000-6-1
DIN 45635-1
DIN EN 60335-1
This is to confirm that the above-mentioned machine complies with the described EU guidelines. This declaration becomes invalid if the machine is modified without our approval.
Place, date: Hamburg, 2022-05-31 | Company stamp : |
---|
Signature:
Sven Wassermann (Managing Director)
|
Notes:
https://www.wassermann.hamburg/
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg
Germany
Phone: +49 (0)40 730 926-20/ -24
export@wassermann-dental.com
www.wassermann.hamburg
/WassermannDentalmaschinen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>