WASSERMANN SG-1-2 D Universal Single Place Suction Unit User Manual
- June 5, 2024
- WASSERMANN
Table of Contents
- Features
- Safety Symbols Used in this Manual
- Safety Guidelines
- Responsibility for Operation or Damage
- Application
- Before Starting
- Installation/ Start-up
- Operation
- Troubleshooting
- Care and Maintenance
- Technical Data
- Disposing of the Unit
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SG-1-2 D Universal Single Place Suction
Unit
User Manual
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann
DentalMaschinen incorporates the highest standards of quality and the latest
technology. In order to enjoy maximum performance and years of trouble-free
operation, please read this user manual carefully before you connect this
device and start work, and operate the device according to the recommended
guidelines. The operation safety and the functionality of this device can only
be guaranteed if you follow both the general safety guidelines and the
applying laws to prevent accidents as well as the precautions given in this
user manual. We are not liable for any damages which occur due to
inappropriate usage or faulty operation of this device.
Make sure that anyone using this device has read and understood this user
manual.
Keep this user manual in a safe place where it can be referred to as required
at any time.
The unit complies with the relevant EU guidelines.
The unit is subject to the EU guidelines 2012/19/EU (WEEE Directive).
Features
- A universal suction unit that works with the low-pressure principle
- Automatic switch-off – also of connected appliances – at filter saturation point
- Integrated plug for rapid power supply to connected peripheral appliances
- Multifunctional use – from polishing trough to fine blasting units
- Completely vibration-free and low-noise running
- Relaxed and nearly noiseless working conditions
- The hands will not become cold even in continuous operation
- Switchover to continuous operation is possible
- Long-life brushless motor
- Low maintenance and almost free from wear
- Safety and health in the workplace: Equipped with a filter bag with a large capacity, optionally available for micro-fine dust or for plaster
- Various accessories for suction technology are available
Safety Symbols Used in this Manual
Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening. These warnings have
to be observed.
Information!
This symbol draws your attention to specific features that have to be
observed.
Safety Guidelines
Configuring and operating this equipment requires precise knowledge and
observance of the instructions in this user manual. The equipment is
designed only for its intended
application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connected to the correct power source.
Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or
user if said device is incorrectly serviced, maintained, or altered by persons
not employed by an authorized dealer or if the device is used in a manner
contrary to its specified purpose. The unit has to be maintained and operated
in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not
responsible for damage arising from the nonobservance of these
instructions.
Warranty and responsibility provisions contained in the sales and supply
conditions of Wassermann Dental-Maschinen GmbH are not extended by these
instructions.
Application
The SG-1/2 D suction unit is a technically proven and solid piece of
equipment made entirely of metal. It is intended primarily for use with the
Cemat range as it has an additional socket for that purpose. Its automatic
cut-out feature, when the filter is full, provides additional protection.
Only use the device for this type of application.
Before Starting
Transport
Before transporting the unit, ensure that it has been unplugged from the power
socket.
Make sure that it is packed correctly in order to avoid accidental damage.
Be sure to check for any transport damage when unpacking the goods. Note down
any damage if found.
Installation
Open the box, remove the packing materials, and carefully lift out the device
and accessories. Check the included accessories.
The device has to stand horizontally on a steady and even surface.
Install the device in a place where it will not block the working area and the
functionality (take the dimensions into account).
Do not install the unit outdoors or in places without proper ventilation.
Before start-up, be sure the device reaches room temperature.
Storage
The unit location is very important when it comes to workplace safety, even if it is only to be set up there for a short period. The room should be dry, well ventilated, and vibration-free. An even temperature and wooden supports also help. The unit should not be stored or set up outdoors. If the unit is to be stored for an extended period, protect it from moisture and dust.
Installation/ Start-up
Before starting the unit, connect up the following:
- Connect the extractor unit to the mains. (Insert the power plug into the socket, making sure that the mains and the unit operate on the same voltage)
- Finishing tools can be plugged into the socket at the side.
- The switch in the earthed plug is used to turn on the suction as well as the power for the finishing tool.
- Turn on the green rocker switch.
- The plate controls the direction of the exiting air.
Operation
General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are based on our own experience and experimentation and can only be regarded as guidelines.
Troubleshooting
Fault | Cause | Solution |
---|---|---|
A full filter red light comes on | Filter full | Change filter or switch to |
continuous operation
Greenlight comes on but nothing happens| Faulty safety plug with a switch or
faulty supply line| Replace safety plug with switch or supply line
If the above recommendations do not solve the problem, contact your dental depot or our service department.
Care and Maintenance
Cleaning
Disconnect the power plug before starting any maintenance work.
The identification plate has always to be kept in easily legible condition and
has not to be removed.
Remove external dirt from time to time with some form of cold cleaner.
Use only cold cleaners to avoid damaging the paintwork or removing the
lettering. The equipment should be cleaned at regular intervals to ensure
trouble-free operation.
It requires only normal cleaning (sponge, damp cloth, mild detergent) and no
further chemical additives.
Maintenance
The unit does not require any servicing. Just make sure that the device is kept clean.
Repairs
Servicing or repairs to the unit have only to be carried out by qualified
technicians.
Only original spare parts are to be used. Responsibility for the product is
voided if unauthorized persons alter it or if inappropriate components are
installed.
Spare Parts
If necessary please contact our service hotline phone.
Service Hotline 0049 (0)40 730 926 -20/ -24
Scope of Delivery/ Accessories
Included parts | Item no. |
---|---|
Supply line with switchable shockproof plug | 140022 |
Conductance sheet | 140108 |
Micro-fine dust filter bag | – – – |
Accessories | Item no. |
--- | --- |
Spare micro-fine dust filter bag (dust class M) 1 set = 4 pieces | 611020 |
Spare filter bag for plaster (class 1 / class 2) 1 set = 3 pieces | 611017 |
Warranty
The warranty period for our equipment is 12 months. If faults occur within the
warranty period, contact your dental depot or get in touch directly with our
service department.
Your equipment should only be operated in perfect condition. If faults occur
which could harm operators or third parties, the unit should not be used until
it has been fixed.
This warranty does not cover damage caused by improper use, external
mechanical causes, transport damage, or interference with the unit by
unauthorized persons.
Technical Data
Universal suction unit SG-1/2 D – Item-No. 140997
Voltage | 220–240 V / 50/60 Hz |
---|---|
Output | 105 W |
Power consumption | 0.5 A |
Power consumption connection unit | max. 2 A |
W x H x D | 410 x 460 x 185 mm |
Weight | 12.7 kg |
Sound level | 61 dB(A) |
Suction capacity | 360 m3/h (free-blowing) |
Other voltages on request.
The noise level of the unit amounts to ≤ 70 dB (A).
Technical changes reserved.
Disposing of the Unit
The unit has to be disposed of by an authorized recycling operation. The selected company has to be informed of all possibly health-hazardous residues in the unit.
Information on Disposal for Countries within the EU
To conserve and protect the environment, prevent environmental pollution, and
improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling.
Within the European Union units with this symbol should not, therefore, be
disposed of in the unsorted domestic waste.
For more information regarding proper disposal please apply at your local
authorities.
EU Declaration of Conformity
In accordance with 2014/35/EU (Low Voltage Directive) and 2014/30/EU (Electromagnetic Compatibility Directive) and 2006/42/EC (Machinery Directive) and 2011/65/EU (RoHS Directive)
Manufacturer: W A S S E R M A N N
Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg
Germany| Model: SG-1/2 D
Applicable standards:
DIN EN 61010-1
DIN EN 61000-6-3
DIN EN 61000-6-1
DIN 45635-1
DIN EN 60335-1| Product description:
Suction Unit for dental applications
Item no. 140997
---|---|---
Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EU-
Richtlinien entspricht. Diese Erklärung wird ungültig, falls die Maschine ohne
unsere Zustimmung verändert wird.
This is to confirm that the above-mentioned machine complies with the
described EU guidelines. This declaration becomes invalid if the machine is
modified without our
approval.
Cette machine est conforme aux normes en vigueur d´Union européenne. Cet avis
est nul et non avenant si cette machine est modifiée sans notre accord.
Place, date: Hamburg, 2021-11-02
Company stamp :
Signature: ____Sven Wassermann
(Managing Director)
https://www.wassermann.hamburg/
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24
Fax.: +49 (0)40 730 37 24
export@wassermann-dental.com
www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen