WASSERMANN Sidomix II Dosing and Mixing Unit User Manual
- June 5, 2024
- WASSERMANN
Table of Contents
- WASSERMANN Sidomix II Dosing and Mixing Unit
- Features
- Safety Symbols Used in this Manual
- Safety Guidelines
- Responsibility for Operation or Damage
- Warranty
- Application
- Installation
- Installation/ Start-up
- Operation
- Troubleshooting
- Care and Maintenance
- Technical Data
- Disposing of the Unit
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WASSERMANN Sidomix II Dosing and Mixing Unit
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann Dental-
Maschinen incorporates the highest standards of quality and the latest
technology.
In order to enjoy maximum performance and years of trouble-free operation,
please read this user manual carefully before you connect this device and
start work, and operate the device according to the recommended guidelines.
The operation safety and the functionality of this device can only be
guaranteed if you follow both the general safety guidelines and the applying
laws to prevent accidents as well as the precautions given in this user
manual. We are not liable for any damages which occur due to inappropriate
usage or faulty operation of this device.
- Make sure that anyone using this device has read and understood this user manual.
- Keep this user manual in a safe place where it can be referred to as required at any time.
- The unit complies with the relevant EU guidelines.
- The unit is subject to the EU guidelines 2012/19/EU (WEEE Directive).
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24 Fax.: +49 (0)40 730 37 24
export@wassermann-dental.com
www.wassermann.hamburg
www.facebook.com/WassermannDentalmaschinen
Features
Mixing and dosing of addition-vulcanizing 1:1 two-component silicones. For even dosage of both components, both must have similar viscosity. The additional quantity flow control ensures an optimum mixing ratio. Should there be discrepancies, for example, for technical reasons (wear of the pump), or following a change of components with different viscosity, the mixing ratio can be adjusted.
Advantages:
- Mixing head with separate output openings – mixing of A and B components while mounting or dismounting the mixing cannula is impossible
- Automatic production of homogeneous silicone material without any loss or bubbles at the press of a button
- Saves material and time by filling more than one bowl at the same time with just a single mixing cannula
- Forced mixing by a disposable mixing cannula, pink with a bayonet mount
- Containers with quick couplings mounted directly on the device
- With quick coupling for mounting of 1 kg and 6 kg or 25 kg
- 1 kg: adapter set available, pad stand not required, connection hoses not required
- 6 kg: adapter set available, optional small pad stand available, (usage with pad stand: connection hoses required)
- 25 kg: tall pad stand required, adapter set with connection hoses required
- The included 2×2 liter material containers feature a quick coupling and can be used immediately.
Safety Symbols Used in this Manual
Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening. These warnings have
to be observed.
Information!
This symbol draws your attention to specific features that have to be
observed.
Safety Guidelines
Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual. The equipment is designed only for its intended application.
WARNING:
Servicing and repairs should be carried out only by authorized specialists.
Disconnect the power plug before starting any maintenance work.
Make sure that the equipment is connected to the correct power source.
Always keep the two silicone components separated – never mix up the
connections! The mixing of components would cause the silicone within the
device to harden, making extensive repairs to the device in the Hamburg plant
necessary.
Drill a ventilation hole using a drill or similar tool at the upper side edge
of the 1-liter bottle or 6 kg or 25 kg can. Do not tighten the caps of the
2-litre material containers, but just fit them loosely to ensure proper
ventilation.
After hardening and before further usage, fit a new mixing cannula.
WARNING: Never use a hardened mixing cannula!
Note that while using bulk containers, the cans must be positioned at a height
higher than the device. Optional pad stands are available on request.
Leave about 2-3 cm minimal filling inside the containers to avoid air getting
into the system and the need for demanding to bleed of the device.
WARNING: It is very important to pay attention to this minimal filling! The pump must never be used without material (never “running dry”)!
Responsibility for Operation or Damage
The responsibility for operating the device lies exclusively with the owner or
user if said device is incorrectly serviced, maintained or altered by persons
not employed by an authorized dealer or if the device is used in a manner
contrary to its specified purpose. The unit has to be maintained and operated
in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not
responsible for damage arising from the nonobservance of these instructions.
Warranty and responsibility provisions contained in the sales and supply
conditions of Wassermann Dental-Maschinen GmbH are not extended by these
instructions.
Warranty
The warranty period for our equipment is 12 months. If faults occur within the
warranty period, contact your dental depot or get in touch directly with our
service department.
Your equipment should only be operated in perfect condition. If faults occur
which could harm operators or third parties, the unit should not be used until
it has been fixed.
This warranty does not cover damage caused by improper use, external
mechanical causes, transport damage or interference with the unit by
unauthorized persons.
Application
Mixing and dosing of addition-vulcanizing 1:1 two-component silicones. For
even dosage of both components, both must have similar viscosity.
Only use the device for this type of application.
Before Starting
Transport
Before transporting the unit, ensure that it has been unplugged from the power
socket. Make sure that it is packed correctly in order to avoid accidental
damage. Be sure to check for any transport damage when unpacking the goods.
Note down any damage if found.
Installation
Open the box, remove the packing materials, and carefully lift out the device
and accessories. Check the included accessories.
The device has to stand horizontally on a steady and even surface.
Install the device in a place where it will not block the working area and the functionality (take the dimensions into account). Make sure that there are about 10 cm of free space on each side to guarantee air circulation (heat dissipation).
Do not install the unit outdoors or in places without proper ventilation.
Before start-up, be sure the device reaches room temperature.
Storage
The unit location is very important when it comes to workplace safety, even if
it is only to be set up there for a short period. The room should be dry, well
ventilated, and vibration-free. An even temperature and wooden supports also
help. The unit should not be stored or set up outdoors. If the unit is to be
stored for an extended period, protect it from moisture and dust.
Installation/ Start-up
Before starting the unit, connect up the following:
- Remove the closing plugs from the connections and dosage head.
- Finally, insert the power plug into the socket, making sure that the mains and the unit operate on the same voltage.
When using 2 Litre Material Containers (included):
Fill the material container with the relevant component.
Warning: Insert the container filled with colored silicone compound –
component B – into the color-marked entry at the back of the device. Do not
mix up! If you mix up the closings even for a short time, the device must be
disassembled and cleaned.
Very important: Do not tighten the caps of the material containers, but just fit them loosely to ensure proper ventilation.
When using 1 kg Bottles:
Remove the closings of the bottles filled with two-component silicone and
screw the above-mentioned metal quick closings (accessories) onto the bottles.
Warning: Screw the color-marked quick closings onto the bottles filled with
colored silicone compound – component B. Do not mix up! If you mix up the
closings even for a short time, the device must be disassembled and cleaned.
Insert the bottles with quick closings into the entry on the back of the
device (the bottles will be upside down).
Very important: Drill a ventilation hole using a drill or similar tool at the upper side edge of the bottles to ensure proper ventilation.
When using 6 kg Bulks:
Remove the closings from the cans filled with two-component silicone and
screw the adaptor set onto the cans.
Warning: Screw the color-marked adapter onto the can filled with colored
silicone compound – component B. Do not mix up! If you mix up the closings
even for a short time, the device must be disassembled and cleaned.
Insert the can with quick closings into the entry on the back of the device
(the can will be upside down).
Very important: Drill a ventilation hole using a drill or similar tool at the upper side edge of the can to ensure proper ventilation.
When using 25 kg Bulks:
Note that while using bulk containers, the cans must be positioned at a height
higher than the device. Optional pad stands are available on request.
Remove the closings from the cans filled with two-component silicone and screw
connection hoses onto the cans.
Warning: Screw the color-marked connection hose onto the can filled with
colored silicone compound – Component B – screw on. Do not mix up! If you mix
up the closings even for a short time, the device must be disassembled and
cleaned.
Place the can, e.g. on the optional pad stand, to make sure that it will be
placed higher than the dosage device (can be upside down), and insert the
connection hoses with quick closings into the entry on the back of the device.
Very important: Drill a ventilation hole using a drill or similar tool at the upper side edge of the can to ensure proper ventilation.
Replacing Bottles/ Cans:
Remove the quick coupling/bottle adaptor from the device by pulling up the
lock. Screw the quick coupling/bottle adaptor onto the new bottle/can and
connect as explained above.
Take special care to never confuse the bottles or connection hoses A+B – not
even for a short time – since the silicone within the connections and pipes
hardens instantly! The cleaning procedure is very demanding and may only be
performed by authorized repair companies.
Note that while using bulk containers, the cans must be positioned at a height
higher than the device. Optional pad stands are available on request.
Operation
General Operating Instructions
All instructions for using the unit, whether in verbal or written form, are
based on our own experience and experimentation and can only be regarded as
guidelines.
Switch on the device; the toggle switch lights green (right side of the unit).
Note for the Quantity Flow Control/ Setting of Quantity Flow Controller
The adjusting screws are located on the side panel of the machine. (Behind the
both-sided bores of the hood, please use a screwdriver.)
-
Controller closed = rotary knob is turned down quite right until it stops.
100% of the component flows from the reservoir to the mixing tip -
Controller open = control range: from 2 to max. 4 turns to the left.
A part of the component flows from the container to the mixing tip and a remaining part of the component flows in the bypass circuit. -
Controller open = About 4 turns to the left. 100% of the component flows in the bypass circuit so that no material flows to the mixing tip.
Initial Start-up and Material Change
The unit will be delivered with a testing liquid filled in!
Observe at the first start-up * or at material change necessarily the
following,
because otherwise, this will cause a mixing of the test liquid and the
material or of “old” and “new” material:
(Please pay attention to sections 3 and Sections 7.1 – 7.5! )
One-time procedure to clean up the hoses and the dosing pump:
Place an empty bowl under the mixing head without a mixing tip. The quantity
flow controllers are located behind the both-sided bores of the hood. Turn
both quantity flow controllers 2 ½ to 3 to the left from the closed position
(stop far right) to the open position by using a screwdriver.
Now press the red button and hold it down until both components run out of the
openings simultaneously and without air bubbles.
Afterward, close the quantity flow controller and check the mixing ratio. If
it is not 1:1, there is the possibility to reduce the quantity flow of the
component that is delivered too much. Therefore open the quantity flow
controller of that component in small steps (from 2 turns to the left in
1/8-turns) in order to optimize the mixing ratio. After each adjustment, are-
inspection is necessary.
Using the Mixing Tips and Dosage
Mount the mixing cannula by turning it 90° on the mixing cannula adaptor
(clean the adaptor before if necessary). Place the bowl or the model to be
used for doubling the system under the mixing cannula. Press the red button:
1:1 mixed silicone runs out of the mixing cannula.
We recommend collecting a small amount of the mixture initially output and just letting the substance output subsequently run into the form. You can fill more forms without changing the mixing cannula as long as the period between the single dosage operations lies within the dripping time of the used silicone (about 4 min.). The dosage machine 1:1 dispenses mixed silicone as long as you press the red button.
After use, leave the mixing cannula attached to the device and allow the remaining silicone to vulcanize. This closes the openings of both components sufficiently.
A new mixing cannula has to be fitted after hardening and before further usage.
WARNING: Never use a hardened mixing cannula!
Very important:
Do not continue operation if one or both containers are empty; otherwise the
pipes will convey air (observe the minimum liquid level of the containers: ~
2-3 cm!).
Troubleshooting
Problem | Cause | Solution |
---|---|---|
No silicone output. | Hardened material within the old cannula. | Mount a new |
mixing cannula.
No silicone output.| Mixing head clogged.| Clean mixing head carefully.
Warning: Silicone components must not get in contact with each other!
No silicone output.| A and B component was mixed up; silicone within the
device system has hardened.| The device needs to be disassembled and cleaned
by a qualified technician.
No silicone output.| Minimum liquid level of the silicone containers was
reached; system has sucked in air.| Add silicone compound. Position a
container under the mixing head without the mixing cannula, press the red
button and hold it until both components run out even and without bubbles from
the mixing cannula adaptors.
Clean the mixing head and connect a new mixing cannula if necessary.
Silicone output without 1:1 ratio.| Silicone components do not have similar
viscosity.| We recommend using Wassermann doubling silicones WaSil soft and
WaSil speed.
Silicone output without 1:1 ratio.| Gears within the pump are not evenly
worn.| With light wear, please see 8.2 notes to the setting of the quantity
flow controller. Should this not suffice, the device needs to be inspected by
a qualified technician.
Silicone output without 1:1 ratio.| The mixing ratio / the quantity flow
controller is not adjusted correctly.| Please see 8.2 notes to the setting of
the quantity flow controller
Care and Maintenance
Cleaning
Disconnect the power plug before starting any maintenance work.
The identification plate has always to be kept in easily legible condition and
has not to be removed.
-
Remove external dirt from time to time with some form of cold cleaner.
Use only cold cleaners to avoid damaging the paintwork or removing the lettering.
The equipment should be cleaned at regular intervals to ensure trouble-free operation. -
It requires only normal cleaning (sponge, damp cloth, mild detergent) and no further chemical additives.
Always keep the mixing cannula adaptor and the quick closings clean.
Maintenance
The unit does not require any servicing. Just make sure that the device is kept clean.
Repairs
Servicing or repairs to the unit have only to be carried out by qualified
technicians.
Only original spare parts are to be used. Responsibility for the product is
voided
if unauthorized persons alter it or if inappropriate components are installed.
Spare parts
If necessary please contact our service hotline phone.
Service hotline 0049 (0)40 / 730 926 -20/ -24
Scope of Delivery/ Accessories
Included parts
Set material cask incl. quick fitting coupling, 2 x 2 liter
Mixing canulas, pink, 10 pcs.
Accessories| Item no.
---|---
Set material cask with quick fitting coupling, 2 x 2 liter| 172640
Stand small for duplicating silicones, 2 x 6 kg-cask| 172631
Stand tall for duplicating silicones, 2 x 25 kg-cask| 172632
Connecting tubes cpl., 2 pcs.| 172633
Adapter-set for duplicating silicones, 2 x 1 kg-cask| 172634
Adapter-set for duplicating silicones, 2 x 6 kg-cask| 172636
Mixing cannulas, pink, 100 pcs.| 622002
Technical Data
**Sidomix II Sidomix II 115 V*** | **Item no.: 172980 Item no.: on request*** |
---|---|
Voltage | 220–240 V / 50/60 Hz |
110–120 V / 50/60 Hz*
Power consumption| 1.6 A
3.2 A*
Output| 260 W
W x H x D (max.)
W x H x D (housing)
| 275 x 340 x 440 mm
242 x 305 x 360 mm
Weight| 11.5 kg
Other voltages on request.
The noise level of the unit amounts to ≤ 70 dB(A).
Disposing of the Unit
The unit has to be disposed of by an authorized recycling operation. The selected company has to be informed of all possibly health-hazardous residues in the unit.
Information on Disposal for Countries within the EU
To conserve and protect the environment, prevent environmental pollution, and
improve the recycling of raw materials, the European Commission adopted a
directive that requires the manufacturer to accept the return of electrical
and electronic units for proper disposal or recycling.
Within the European Union units with this symbol should not, therefore, be
disposed of in the unsorted domestic waste.
For more information regarding proper disposal please apply at your local
authority.
EU Declaration of Conformity
Hiermit wird bestätigt, dass die oben bezeichnete Maschine den genannten EU-
Richtlinien entspricht. Diese Erklärung wird ungültig, falls die Maschine ohne
unsere Zustimmung verändert wird.
This is to confirm that the above-mentioned machine complies with the
described EU guidelines. This declaration becomes invalid if the machine is
modified without our approval.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>