levenhuk WA20 Weather Station User Manual

June 5, 2024
levenhuk

levenhuk WA20 Weather Station

Base station

  1. SNOOZE/LIGHT button
  2. Outdoor temperature and humidity
  3. Time display
  4. MODE button
  5. SET button
  6. Weather forecast
  7. ALARM button
  8. Moon phase
  9. CHANNEL button
  10. Atmospheric pressure
  11. UP button
  12. DOWN button
  13. Weekday
  14. Calendar
  15. Indoor temperature and humidity
  16. Wall mount holes
  17. Battery compartment
  18. Table stand (fold-out)
  19. Power input

Sensor

  1. LED indicator
  2. Channel switch (1—3)
  3. Wall mount hole
  4. Battery compartment

Getting started

Base station

  • Connect the power cable to the device and connect the DC adapter to the AC power supply; or
  • Open the battery compartment cover (17) and insert 3 batteries according to the correct polarity. Close the cover.

Sensor

  • Open the battery compartment cover (4). Insert 2 batteries according to the correct polarity. Close the cover.

Sensor connection

  • Place the base station and the remote sensor within the effective transmission range.
  • If the reception is successful, the display will show the temperature and humidity of the outdoor sensor. If the values are not received from a channel, check the batteries and try it again. Check if there is any source of interference.
  • When changing batteries, replace the batteries first in the base unit, and then in the sensor, to re-establish the connection. If you change the batteries only in one of the devices (for example, in the sensor), the signal may not be received correctly.
  • This weather station can support up to 3 sensors. To search for the sensors manually, press and hold the CHANNEL button on the base station, and then press this button again to choose between channels 1, 2, or 3.
  • The effective range may differ depending on the unit’s position. Due to interference (various remote control devices, etc.), the maximum distance between the base unit and the sensor may be significantly reduced. In such cases, we suggest moving the base unit and sensor a little. Sometimes it is enough to move one of these units a few inches!

Time setting
Press the MODE button. Hold the SET button for 3 seconds. The digits that are to be set are flashing. Press UP or DOWN to change the value, and then press SET to continue. The setting order: Time zone > Day Saving Time > Year > Month-Day or Day-Month > Month > Day > 12/24h > Hour > Minutes > Seconds. Press the SET button to confirm the settings and exit.

Alarm setting

  • To turn the alarm 1/alarm 2 on or off, press the ALARM button.
  • To set alarm 1 and alarm 2, first press the MODE button twice. Hold the SET button for 3 seconds. The digits that are to be set are flashing. Press UP or DOWN to change the value, and then press the SET button to continue. The setting order: Alarm 1 hours > Alarm 1 minutes > Alarm 2 hours > Alarm 2 minutes. Press the SET button to confirm the settings and exit.
  • When the alarm sounds, press SNOOZE/LIGHT to activate the snooze function. The alarm will sound again in 5 minutes.
  • Press any button to silence the alarm until the set alarm time is reached again.

Atmospheric pressure height setting

Press the MODE button 3 times. Hold the SET button for 3 seconds. The digits that are to be set are flashing. Press UP or DOWN to insert the desired height. Press the SET button to confirm the settings and exit.

Temperature alert setting
Press the MODE button 4 times. Hold the SET button for 3 seconds. The digits that are to be set are flashing. Press UP or DOWN to change the value. Press the SET button to continue. The setting order: Low outdoor temperature alert > Low outdoor temperature alert on/off > High outdoor temperature alert > High outdoor temperature alert on/off > Low  indoor temperature alert > Low indoor temperature alert on/off > High indoor temperature alert > High indoor temperature alert on/off. Press the SET button to confirm the settings and exit.

Temperature units of measurement
Press the SET button to switch between °C and °F.

Weather forecast

History record
Press the UP button to display the MAX./MIN. temperature and humidity.

Moon phase

The moon phase display is linked to the date, year, and time. The stars are displayed between 6 pm and 6 am.

Specifications

Base station

Air humidity, units of measurement| % (RH)
Operating humidity range| 1… 99%
Temperature, units of measurement| °F, °C
Operating temperature range (indoors)| –10… +50°C (+14… +122°F)
Air pressure, units of measurement| inHg, hPa, mmgh
Operating air pressure range| 800… 1100hPa (23.6… 32.4inHg)
Screen| color, with an LED backlight
Power supply| AC/DC adapter 5V 300mA (included), З ААА batteries (not included)
Dimensions| 191.6x127x16mm (7.5x5x0.6in.)

Sensor

Radio signal frequency| 433.92MHz
Radio signal radius| 100m (328ft.)
Operating temperature range (outdoors)| –40… +70°C (–40… +158°F)
Power supply| 2 AAA batteries (not included)
Dimensions| 40x98x25mm (1.5×3.8×0.9in.)

Care and maintenance

  • Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions.
  • Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center.
  • Protect the device from sudden impact and excessive mechanical force.
  • Store the device in a dry, cool place away from hazardous acids and other chemicals, away from heaters, open fire, and other sources of high temperatures.
  • Operate the device only in a completely dry environment and do not touch the device with wet or damp body parts.
  • Only use accessories and spare parts for this device that comply with the technical specifications.
  • Check this device and its cables and connections for any possible damage before use.
  • Never attempt to operate a damaged device or a device with damaged electrical parts! Damaged parts must be replaced immediately by an authorized service agent.
  • If a part of the device or battery is swallowed, seek medical attention immediately.
  • Children should use the device under adult supervision only.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Levenhuk Warranty

Levenhuk products, except for their accessories, carry a 2-year warranty against defects in materials and workmanship. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met. For further details, please visit: www.levenhuk.com/warranty If warranty problems arise or if you need assistance in using your product, please contact the local Levenhuk branch.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals